Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge)

Buyer Rates Mã sản phẩm: 16782

Model: Labculture ® Class II Loại B2
Manufacturer: ESCO
Status: Stocking
Guarantee: 12 months
Price: Contact

Esco’s Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge) is NSF-49 certified and is designed to provide operator, product and environmental protection during recirculation prohibited experiments. filtration, most likely due to the presence of chemical fumes emitted during the process.

Description

Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge) with filters that cannot capture chemical fumes; and would be harmful to the operator if recirculated in the laboratory space. Therefore, Class II Class B2 cabinets must be directed to an external blower for complete discharge. Similar in design to Class II Type A2 cabinets, Type B2 cabinets are suitable for work-related testing at any level of biosafety containment..

This Labculture ® Class II Type B2 Microbiological Safety Cabinet requires integration with an external blower.

I. Specification Labculture ® Class II type B2 biological safety cabinet (full discharge)

Sentinel™ Gold Microprocessor Control System:

  • There are audible and visual alarms
  • Display all safety information on one screen
  • Centered and tilted down for easy access and viewing
  • Selectable Quick Start mode for quick operation.

Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge)

Efficient dual DC-ECM blower system:

  • Powered by latest generation DC ECM motor, more efficient than legacy ECM and VFD motors
  • 70% energy saving compared to AC motor
  • Stable airflow, despite voltage fluctuations and filter loads
  • Night setting mode to further reduce power consumption by 60%.

Labculture ® Class II Type B2 (full discharge) Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge)

Filter ULPA:

  • 10 x filtration efficiency compared to HEPA filter
  • Create an ISO Class 3 workspace instead of the industry standard ISO Class 5
  • 99.999% at 0.1 to 0.3 micron, ULPA according to IEST-RP-CC001.3 USA or >99.999% at MPPS, H14 according to EN 1822 EU.
  • Esco cabinets use ULPA (according to IEST-RP-CC001.3) / H14 filter on EN 1822 instead of HEPA H13 filter used on many
  • BSCs on the market.

Labculture ® Class II Type B2 (full discharge) Labculture ® Class II Type B2 (full discharge)

Cabinet structure:

  • Stainless steel side walls with side capture zones and negative pressure for optimized containment
  • Easy access to service devices
  • One-piece work tray, spill resistant and easy to clean.

Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge)

Angled Drain Pan:

  • Easy to clean
  • Contains no contaminant.

Labculture ® Class II Type B2 (full discharge)

Adjustable UV timer:

  • Easily adjust to desired minutes or hours
  • Extend the using time of the UV lamp, if not turn ON the lamp overnight.

Labculture ® Class II Type B2 (full discharge)

ISOCIDE™ Coating:

  • Silver ion impregnated powder coat
  • Inhibits microbial growth for improved safety.

Labculture ® Class II Type B2 (full discharge)

Labculture ® Class II Type B2 Cabinet Filtration System:

  • Ambient air is pulled through the front grille to create an inlet without entering the work surface. The inlet is joined by a downward half, to create a front air curtain that is fine-tuned to create a large performance envelope. The combined airflow passes through the rear air column towards the blower.
  • About ⅓ of the air in the common room is expelled through the ULPA filter into the room. ⅔ remaining air is passed through the downflow ULPA filter and into the work area as vertical laminar flow air to create an ISO Class 3 work surface and prevent cross contamination.
  • Near the work surface, the downflow separates. About half belongs to the front grille and half belongs to the rear grille. A small portion goes into the side snap areas to prevent dead air angles (small blue arrows)
  • Optimized design for great performance, providing operator and product protection at wide Inflow and Downflow variations from Nominal point.

Isocide ™ Antibacterial Powder Coating:

  • Removes 99.9% of bacteria on surfaces within 24 hours of contact.

Labculture ® Class II Type B2 (full discharge)

II. Advantages of Labculture ® Microbiological Safety Cabinet Class II Type B2

  • Labculture ® Class II Microbiological Safety Cabinets Type B2 (full flush) with latest generation DC ECM motor made in the USA.
  • The negative pressure overflow spans the contaminated positive pressure overflow. Do not use cloth bags.
  • Long life ULPA filter for feed and discharge (according to IEST-RP-CC001.3) with 99.999% efficiency for 0.1 to 0.3 micron particle sizes
  • Covered one-piece work surface containing spillage. The absence of screws or connectors in the work area facilitates easy cleaning and decontamination.
  • One-piece back wall with cove corners to ensure thorough cleaning and decontamination
  • Power supply filter is angled to match cabinet configuration for best downflow uniformity
  • Esco Sentinel TM Gold processor with large blue LCD display all safety parameters simultaneously on a single screen.
  • Quick start mode, to turn on/off the blower and lights by moving the window pane to the correct position.
  • The RS 232 data output port allows remote monitoring of the cabinet’s operating parameters.
  • Frameless shields are easier to clean.
  • The angled front panel improves reach and comfort.
  • The screen tilts down and the panel is ADA compliant.
  • The raised grille helps maintain safety by preventing blockages.
  • Esco ISOCIDE TM anti-bacterial coating on all painted surfaces helps to reduce contamination.
  • Advanced side-captured areas optimize containment.

***For more detailed technical information, as well as to select the appropriate Labculture ® Microbiological Safety Cabinet Class II Class B2 model; Please Contact GMGA . Our professional technicians are always ready to assist you 24/7.

III. Specifications Labculture ® Microbiological Safety Cabinet Class II Type B2

TECHNICAL SPECIFICATIONS

Labculture® Class II B2 LB2-3B_-E LB2-4B_-E LB2-5B_-E LB2-6B_-E LB2-8B_-E
Nominal Size 0.9 meter (3′) 1.2 meter (4′) 1.5 meter (5′) 1.8 meter (6′) 2.4 meters (8′)
External Dimensions * (W x D x H) Without Base Stand 1115 x 852 x 1610 mm
(44.0″ x 33.5″ x 63.3″)
1420 x 852 x 1610 mm
(56.0″ x 33.5″ x 63.3″)
1725 x 852 x 1610 mm
(68.0″ x 33.5″ x 63.3″)
2030 x 852 x 1610 mm
(80.0″ x 33.5″ x 63.3″)
2600 x 852 x 1610 mm
(102.4″ x 33.5″ x 63.3″)
With Optional Base Stand,
711 mm (28″) type
1115 x 852 x 2321 mm
(44.0″ x 33.5″ x 91.4″)
1420 x 852 x 2321 mm
(56.0″ x 33.5″ x 91.4″)
1725 x 852 x 2321 mm
(68.0″ x 33.5″ x 91.4″)
2030 x 852 x 2321 mm
(80.0″ x 33.5″ x 91.4″)
2600 x 852 x 2321 mm
(102.4″ x 33.5″ x 91.4″)
Internal Dimensions (W x D x H) 970 x 623 x 715 mm
(38.2″ x 24.5″ x 28.1″)
1270 x 623 x 715 mm
(50.0″ x 24.5″ x 28.1″)
1570 x 623 x 715 mm
(61.8″ x 24.5″ x 28.1″)
1870 x 623 x 715 mm
(73.6″ x 24.5″ x 28.1″)
2440 x 623 x 715 mm
(96.0″ x 24.5″ x 28.1″)
Usable Work Area 0.45 m2 (4.8 sq.ft.) 0.6 m2 (6.5 sq.ft.) 0.75 m2 (8.1 sq.ft.) 0.9 m2 (9.7 sq.ft.) 1.2 m2 (13 sq.ft.)
Tested Opening 203 mm (8.0″) 203 mm (8.0″) 203 mm (8.0″) 203 mm (8.0″) 203 mm (8.0″)
Working Opening 274 mm (10.8″) 274 mm (10.8″) 274 mm (10.8″) 248 mm (9.8″) 248 mm (9.8″)
Average Airflow Velocity Inflow 0.53 m/s (105 fpm)
Downflow 0.31 m/s (60 fpm)
Airflow Volume Inflow 376 m3/h (223 cfm) 492 m3 / h (292 cfm) 608 m3 / h (361 cfm) 724 m3 / h (429 cfm) 945 m3 / h (560 cfm)
Downflow 628 m3
/h (363 cfm)
822 m3
/h (476 cfm)
1016 m3
/h (588 cfm)
1210 m3
/h (700 cfm)
1580 m3
/h (914 cfm)
CBV Exhaust Air Volume** 1127 m3
/h (658 cfm)
1476 m3
/h (862 cfm)
1824 m3
/h (1065 cfm)
2173 m3
/h (1269 cfm)
2835 m3
/h (1656 cfm)
Min Exhaust Static Pressure 400 Pa / 1.6 in H20 375 Pa / 1.5 in H20 375 Pa / 1.5 in H20 400 Pa / 1.6 in H20 475 Pa / 1.9 in H20
CBV Exhaust Static Pressure** 575 Pa / 2.3 in H20 550 Pa / 2.2 in H20 550 Pa / 2.2 in H20 575 Pa / 2.3 in H20 650 Pa / 2.6 in H20
Supply ULPA Filter Typical Efficiency ≥99.999% for particle size between 0.1 to 0.3 microns
Exhaust HEPA Filter Typical Efficiency ≥99.99% at 0.3 microns
Maximum Sash Opening 508 mm (20″)
Sound
Emission***
NSF / ANSI 49 57 dBA 58 dBA 59 dBA 60 dBA 61 dBA
EN 12469 54 dBA 55 dBA 56 dBA 57 dBA 58 dBA
Fluorescent Lamp Intensity At Zero Ambient >1000lux
(>93 foot-candles)
Cabinet
Construction
Main Body Electro-galvanized steel with white oven-baked epoxy-polyester Isocide™ antimicrobial powder-coated finish,
1.5 mm (0.06″) / 16 gauge thick
Work Zone Stainless steel Type 304 with No.4 finish, 1.5 mm (0.06″) / 16 gauge thick
Electrical  Full Load Amps 230 V 8 A no LB2-8ft
Full Load Amps 115 V 10 A 10 A and 5 A
Heat Load 566 BTU/Hr 645 BTU/Hr 781 BTU/Hr 860 BTU/Hr 1177 BTU/Hr
Nominal Power Consumption 166 W 189 W 229 W 252 W 345 W
Net Weight*** 279 Kg (615 lbs) 317 Kg (699 lbs) 359 Kg (791 lbs) 438 Kg (966 lbs) 591 Kg (1304 lbs)
Shipping Weight*** 318 Kg (703 lbs) 370 Kg (814 lbs) 402 Kg (886 lbs) 491 Kg (1083 lbs) 651 Kg (1435 lbs)
Shipping Dimensions, Maximum
(W x D x H)****
1210 x 950 x 1950 mm
(47.6″ x 37.4″ x 76.8″)
1520 x 950 x 1950 mm
(59.8″ x 37.4″ x 76.8″)
1900 x 950 x 1950 mm
(74.8″ x 37.4″ x 76.8″)
2150 x 950 x 1950 mm
(84.7″ x 37.4″ x 76.8″)
2720 x 950 x 1950 mm
(107.0″ x 37.4″ x 76.8″)
Shipping Volume, Maximum**** 2.24 m3 (79.1 cu.ft.) 2.82 m3 (99.6 cu.ft.) 3.52 m3 (124.3 cu.ft.) 3.98 m3 (140.6 cu.ft.) 5.04 m3 (178.0 cu.ft.)

Model LB2 Biological Safety Cabinet Engineering Drawing:

Labculture ® Microbiological Safety Cabinet Class II Class B2 (full discharge)

IV. Accessories for Labculture ® Class II Biological Safety Cabinets LA2, LB2 and LR2

Accessories for LA2, LB2 and LR2 Biological Safety Cabinets

Cabinet

Stainless Steel Side Wall LA2-3A1-E
2010705
LA2-4A1-E
2010670
LA2-5A1-E
2010671
LA2-6A1-E
2010672
LA2-8A1-E
2010928
LA2-3A2-E
2010706
LA2-4A2-E
2010691
LA2-5A2-E
2010692
LA2-6A2-E
2010693

LA2-8A2-E
2011205

LA2-3A3-E
2010707

LA2-4A3-E
2010685
LA2-5A3-E
2010686
LA2-6A3-E
2010687
LA2-8A3-E
2010921
LB2-3B1-E
2010708
LB2-4B1-E
2010673
LB2-5B1-E
2010674
LB2-6B1-E
2010682

LB2-3B2-E
2010709

LB2-4B2-E
2010694
LB2-5B2-E
2010695
LB2-6B2-E
2010696
LB2-8B2-E
2011206
LB2-3B3-E
2010710
LB2-4B3-E
2010688
LB2-5B3-E
2010689
LB2-6B3-E
2010690

LR2-4S1-E
2010845
LR2-5S1-E
2010847
LR2-6S1-E
2010849
LR2-3S2-E
2010701
LR2-4S2-E
2010702
LR2-5S2-E
2010703
LR2-6S2-E
2010704

LR2-8S2-E
2011006

LR2-3S3-E
2010913

LR2-4S3-E
2010851
LR2-5S3-E
2010853
LR2-6S3-E
2010855
Exhaust Ducting Anti-blowback
Valve 10 inches
(LA2 & LR2 only
EG Powder
Coated

ABBV-10P
5170352

304 Stainless
Stee

ABBV-10S
5170354
Anti-blowback
Valve 12 inches
(LB2 only)
EG Powder
Coated

ABBV-12P
5170353

304 Stainless
Steel

ABBV-12S
5170355
Exhaust Damper

B2-DAMPER
5170104

Exhaust Collar (LA2 & LR2 only)

ECO-LA23-MK3-LH
5170097
ECO-LA24-MK3-LH
5170099
ECO-LA25-MK3-LH
5170101
ECO-LA26-MK3-LH
5170102
ECO-LA28-MK3-LH
5170536
Inlet Collar (LB2 only) ICO-LB23
5170320
ICO-LB24
5170263
ICO-LB25
5170316
ICO-LB26
5170322

ICO-LB28
5170692

Pre-filter (LB2 only

PF-2
6090001
Electrical Outlet UV Lamp UV-15A-L
5170251
UV-30A-L
5170255

UV-15A-L (x2)
5170251

IV Bar

IV-955
5170276
IV-1260
5170277
IV-1265
5170278
IV-1870
5170279
Direct Mounted / GFCI

EO-_

Service Fixtures

EU SF-Gas-40 mm

SF-1G40
5170002
EU SF-Vacuum-40 mm

SF-1V40
5170003

EU SF-Air-40 mm

SF-1A40
5170006

EU SF-Nitrogen-40 mm

SF-1N40
51700011
EU SF-Water-40 mm

SF-1W40
51700017

EU SF-Universal-40 mm

SF-2U40
51700018
Support Stands,
Ships Flat
Fixed Stand with
Leveling Feet, 28” height
SPL-3A0 Gen 2
5130188
SPL-4A0 Gen 2
5130189
SPL-5A0 Gen 2
5130190
SPL-6A0 Gen 2
5130163

SPBL-8A0
5131286

Fixed Stand with
Leveling Feet, 34” height

SPL-3B0 Gen 2
5131092
SPL-4B0 Gen 2
5130151
SPL-5B0 Gen 2
5131093
SPL-6B0 Gen 2
5131094
SPBL-8B0
5131287
Fixed Stand with
Caster Wheels, 28” height
SPC-3A0 Gen 2
5130155
SPC-4A0 Gen 2
5130152
SPC-5A0 Gen 2
5130162
SPC-6A0 Gen 2
5130154

SPC-8A0 Gen 2
5131122

Fixed Stand
with Caster Wheels,
34” height

SPC-3B0 Gen 2
5130165
SPC-4B0 Gen 2
5130166
SPC-5B0 Gen 2
5130167
SPC-6B0 Gen 2
5130168
SPC-8B0 Gen 2
5131123
Telescopic Stand
with Leveling Feet,
1” adjustment
STL-3A0
5130050
STL-4A0
5130051
STL-5A0
5130052
STL-6A0
5130053

STL-8A0
5130054

Telescopic Stand
with Caster Wheels,
1” adjustment

STC-3A0
5130055
STC-4A0
5130056
STC-5A0
5130057
STC-6A0
5130058
STC-8A0
5130059
Motorized Height Stand
with Caster Wheels,
39.5” height
SPM-3A_ SPM-4A_ SPM-5A_ SPM-6A_

SPM-8A_

Misc

Arm Rest Padding MEWREST
5170127
Foot Rest

FT-REST
5170492

Laboratory Chair

ME-LD-AR360
1150006
IQ OQ Protocol

9010179

***Watch videos of Class I, Class II, Class III biological safety cabinets at: Gmga Measuring Youtube.

Reviews

There are no reviews yet.

Be the first to review “Labculture ® Microbiological Safety Cabinet Class II Type B2 (full discharge)”

Your email address will not be published.