Wireless noise meter Spartan 730

Price: Liên hệ

Model Spartan 730-KP
Manufacturer Larson Davis
Power supply
Weight
Size
Condition Còn hàng
Warranty 12 tháng

I. Specification of Wireless noise meter Spartan 730

  • With the Spartan 730 Noise Meter, control test setup and measurements directly from the Larson Davis AtlasTM mobile app. All necessary tasks can be completed from the user's iOSTM or AndroidTM device.
  • LD Atlas allows users to monitor remotely without draining the dosimeter's battery, ensuring that users receive the valuable data they need the first time.
  • Once the test is complete, Spartan communicates with LD Atlas to download the data, which can be viewed directly from a phone or tablet.
  • The Spartan 730 Wireless Loudness Meter helps generate reports, including entire data files, from the mobile interface before sharing via email. The Spartan line also includes the intrinsically safe Noise Meter, Model 730IS, for explosive atmospheres.

II. Typical applications

  • Measurements of workers' noise exposure
  • Task-based noise measurement
  • Compliant with OSHA, MSHA, ACGIH and ISO 9612
  • Complies with EU Directive 2003/10 / EC.
Wireless noise meter Spartan 730

III. Wireless noise meter Spartan 730 - Simplify sound measurements

  • Truly wireless - with wireless charging and Bluetooth 4.1 low energy communication.
  • Full control and live monitoring via the LD Atlas app.
  • Download and view measurements, generate reports, and share annotated data from the app.
  • Automatically connect and download data through G4 LD Utility software without human intervention.
  • Optional event recording (730 ESR).
  • Optional 1/1 Octave filter (730 OB1).
  • Non-Bluetooth version available for data download via USB (730 NBT).

Steps to take:

  • To begin testing, simply remove the dosimeters from the sturdy carrying case and attach them to the worker's clothing.
  • After a shift, put the dosimeters back in case they will charge and data can be downloaded.
  • Integrated motion and impact measurements, combined with optional event recording and 1/1 Octave frequency analysis, provide additional data to help you understand what's causing the noise.
  • The G4 LD Utility software provides another option for taking control of your test. With all the functionality of the LD Atlas mobile app, G4 LD Utility adds the ability to complete a "what if" analysis to model potential changes and determine the impact of choices different data.

IV. Spartan 730-KP noise meter kit

  • Spartan offers users options from a single noise dosimeter to a set of ten dosimeters.
  • Each Spartan 730 wireless noise meter kit comes in a sturdy carrying case, ideal for taking the meter into the field.
  • When the job is done, simply pack the dosimeter and move it to the next test site. Kits come in one-, three-, five-, and ten-meter configurations and are available with or without a calibrator.

Wireless noise meter Spartan 730 Wireless noise meter Spartan 730

Spartan 730Spartan 730

V. Specifications of Wireless noise meter Spartan 730

SPECIFICATIONS

Performance

Standards

ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2
Linear Operating Range

52 – 140 dB rms A-weighted

Dynamic Range

94 dB
Peak Range

78 – 143 dB Peak, C-weighted

Peak Weightings

A, C, Z
RMS Weightings

A, C, Z

Time Weightings

Slow, Fast, Impulse
Frequency Range

20 Hz to 10 kHz

Data Logging

Selectable 1 second or 1 minute samples
Logged Data

LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion

Memory

8 GB internal
Communications

Bluetooth Low Energy 4.1

USB 2.0 (Micro-B connector)

Battery

Rechargeable Lithium Ion

Run Time

40 hours, typical
Charge Time

3 hours from full discharge

Charger

Qi-compliant wireless or USB
Compliance

CE, ROHS, WEEE

Motion

Overall motion percentage and bump
Languages

English, Spanish, Italian, French, Portuguese, German

Virtual Dosimeter
Virtual Dosimeters

4 independent with configurable LED indication

Exchange Rate

3, 4, 5, 6
Criterion Level

70.0 to 100.0 dB

Threshold

70.0 to 100.0 dB
Shift Time

1 to 24 hours

Alarms

2 independent with configurable indication
Measurement Results

Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d

Summary Measured Values (Common to all virtual dosimeters)

LωΤ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωΤMax (Lmax), LωΤMin (Lmin) where

     ω = A, C, or Z frequency weighting

     Τ = F, S, or I time weighting

Lpeak, Lmax, & Lmin including time of occurrence

LC-A, Exposure (Pa2s & Pa2h), Motion

Exceedance count and time for 2 rms and 3 peak thresholds

Overload count, duration and percentage

Mechanical
Display

Color LCD 176 x 176 pixels, always on with low light sensor and front light

Ingress Protection

IP65
Keys

Four buttons

Weight

112 g (4.2 oz.) including clips and windscreen
Dimensions

85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only

Microphone

¼-inch Model 375A03
Operating Temperature

–10 to +50 ℃ (14 to 122 ℉)

Operating Humidity

Up to 90% RH, non-condensing
1/1 Octave Filters (optional)

Standards

ANSI/ASA S1.11-2014; IEC 61260-1:2014 Class 1
Filters

31.5 Hz to 8 kHz

Linear Operating Range

42 to 140 dB @ 1 kHz
Measured Results

LZeq (Leq), LZΤMax (Lmax), LZΤMin (Lmin)

Event Audio Recording (optional)
Format

16-bit .wav

Sample Rate

8 kHz
Recording Time

Fixed: 2 s pre-trigger and 10 s post-trigger

Trigger Source

LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s
Trigger Level

40 – 140 dB, selectable

  ***View more GMGA noise meters at: https://gmga.vn/en/danh-muc/measuring-device/noise-meter/

VI. Ordering information Spartan 730-KP noise meter

MODEL NUMBER

DESCRIPTION

730

Spartan 730 noise dosimeter with one windscreen and two clips. Includes calibration certificate

730‑PKxx‑EU 730‑PKxx‑UK 730‑PKxx‑US

Complete Spartan 730 noise dosimeter kit that includes quantity ‘xx’ dosimeters and one USB to Bluetooth dongle. Each dosimeter includes one windscreen, two clips, and a calibration certificate. Versions without CAL150 calibrator available.
‘xx’ Spartan 730 Dosimeters Calibrator (qty 1) Calibration Adapter

Case

1

1 CAL150 1 x ADP109 CCS056

3

3 CAL150 2 x ADP109

CCS057

5

5 CAL150 2 x ADP109 CCS058

10

10 CAL150 2 x ADP109

CCS059

- EU includes a Type C power plug for use in Europe

- UK includes a Type G power plug for use in the UK

- US includes a Type A power plug for use in North America

730-PK01-OPT1

Spartan 730 noise dosimeter kit with one dosimeter, one windscreen, two clips, USB Bluetooth dongle, and rugged case with built-in wireless Qi charger. Includes calibration certificate and universal power adapter.

730‑ESR

Spartan 730 option to add event sound recording
730‑OB1

Spartan 730 option to add 1/1 octave filters

730‑NBT

Spartan 730 option to remove Bluetooth capability
Accessories

730-CLIPS

Replacement clip for Spartan 730, quantity 2
ADP106

BNC to ¼ inch microphone electrical equivalent with 8 pF capacitance used for electrical testing of the Spartan 730

ADP109

Calibrator adaptor for ½ in. to ¼ in. opening. Used with Spartan 730
BAT022

Replacement lithium battery for Spartan 730. Must be installed at a factory-authorized location. Does not include fee for installation.

CCS056

Spartan 730 case for single dosimeter kit that includes single wireless charger and universal power adapter. Spartan 730 and CAL150 not included.
CCS057-EU CCS057-UK CCS057-US

Spartan 730 case for three dosimeter kit that include three wireless chargers. Specify AC plug as “-EU”, “-UK”, or “-US”. Spartan 730 dosimeters and CAL150 not included.

CCS058-EU CCS058-UK CCS058-US

Spartan 730 case for five dosimeter kit that include five wireless chargers. Specify AC plug as “-EU”, “-UK”, or “-US”. Spartan 730 dosimeters and CAL150 not included.
CCS059-EU CCS059-UK CCS059-US

Spartan 730 case for ten dosimeter kit that include ten wireless chargers. Specify AC plug as “-EU”, “-UK”, or “-US”. Spartan 730 dosimeters and CAL150 not included

CER‑730

ISO 17025 factory calibration and certification of Spartan 730
CER-730-OBA

Calibration and certification for Spartan 730 dosimeter including 1/1 octave filters. ISO 17025 accredited

DVX016

USB to Bluetooth dongle used with Spartan 730
PSA042

Wireless Qi charger pad including USB cable and universal power supply

WS012‑XX

Replacement windscreen for Spartan 730. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens
375A03

Replacement ¼ inch microphone for Spartan 730 dosimeter

CAL150

Class 2 calibrator, with user-selectable output 94 or 114 dB at 1 kHz, ½ in. opening with ¼ in. adaptor (ADP109) and calibration certificate included
CER-CAL150

Calibration and certification for CAL150.

  ***Product main path: http://www.larsondavis.com/products/dosimeters/spartan-730

Review Wireless noise meter Spartan 730

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Wireless noise meter Spartan 730
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide