Home » Products » Measuring Equipment » Noise meter » Spartan™ 730IS intrinsically safe noise dosimeter
Spartan™ 730IS intrinsically safe noise dosimeter
Price: Liên hệ
Model | Spartan ™ 730IS-PK |
Manufacturer | Larson Davis |
Power supply | |
Weight | |
Size | |
Condition | Còn hàng |
Warranty | 12 tháng |
I. Specification of Spartan™ 730IS intrinsically safe noise level machine
- Spartan™ 730IS intrinsically safe noise dosimeter Simple design and intuitive setup make worker noise dosimeter easy and quick. With the Spartan-IS, control setup and test measurements on the instrument itself or directly from the Larson Davis
- Atlas™ mobile app. All necessary tasks can be completed from your iOS® or Android® device. The Spartan™ 730IS-PK Series Content Safety Meters are designed to safely perform noise exposure measurements, even for workers in potentially explosive environments, such as in the petrochemical industry and export products.
II. Outstanding applications of the 730IS wireless safety noise meter
- Measurements of workers' noise exposure
- Research on risk reduction
- Measuring compliance with OSHA, ACGIH, ISO 9612 and EU Directive 2003/10/EC.
III. Spartan™ 730IS intrinsically safe noise dosimeter - Simplify sound measurements
- ATEX, UL 913, IECEx, FCC, CAN/CSA C22.2 Approved
- Wireless operation, charging and Bluetooth low energy communication (available without Bluetooth for regions without. radio)
- Spartan™ 730IS intrinsically safe noise dosimeter with full control and direct monitoring via the LD Atlas™ app*
- Download and view measurements, generate reports and share annotated data from your mobile device
- Built-in motion and collision detection
- Automatic dosimeter calibration.
- Steps to take: - To begin testing, simply remove the dosimeters from the sturdy carrying case and attach them to the worker. - After work, put the dosimeters back in case they will charge wirelessly. The G4 LD Utility software provides another option for controlling the testing process. - With all the functionality of the LD Atlas mobile app, G4 LD Utility adds the ability to complete a "what if" analysis to model potential changes and determine the impact of choices different data. - LD Atlas offers low-energy Bluetooth interference-free monitoring, ensuring that you get the valuable data your users need the first time. - When the test is complete, the Spartan-IS communicates with the LD Atlas to download the data, which can be viewed directly from a phone or tablet. Generate reports, including entire data files, from the mobile interface before sharing via email. - For high security, radio-free zones, optional 730-NBT without Bluetooth is available and allows setup and data download via G4 LD Utility software via USB connection.
IV. Safety rating sheet
ATEX / IECEx |
USA / CAN |
II 1G Ex ia IIC T165 °C Ga |
Class I, Zone 0, AEx ia IIC |
I 1M Ex ia I Ma |
T165 °C Ga |
IECEx ETL 19.0045X |
Class I, Division 1, |
ITS20ATEX205538X |
Groups A, B, C & D, T165 °C |
-10 °C ≤ TAMB ≤ +50 °C |
-10 °C ≤ TAMB ≤ +50 ºC |
V. Specifications of Spartan™ 730IS intrinsically safe noise dosimeter
SPECIFICATIONS |
|
Performance |
|
Standards |
ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 |
Linear Operating Range |
52 – 140 dB rms A-weighted |
Dynamic Range |
94 dB |
Peak Range |
78 – 143 dB Peak, C-weighted |
Peak Weightings |
A, C, Z |
RMS Weightings |
A, C, Z |
Time Weightings |
Slow, Fast, Impulse |
Frequency Range |
20 Hz to 10 kHz |
Data Logging |
Selectable 1 second or 1 minute samples |
Logged Data |
LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion |
Memory |
8 GB internal |
Communications |
Bluetooth Low Energy 4.1 |
USB 2.0 (Micro-B connector) |
|
Battery |
Rechargeable NiMH |
Run Time |
30 hours typical |
Charge Time |
16 hours from full discharge |
Charger |
Qi-compliant wireless or USB |
Compliance |
CE, ROHS, WEEE |
Approvals |
ATEX, UL 913, IECEx, FCC, CAN/CSA C22.2 |
Motion |
Overall motion percentage and bump |
Languages |
English, Spanish, Italian, French, Portuguese, German, Finnish |
Virtual Dosimeter |
|
Virtual Dosimeters |
4 independent with configurable LED indication |
Exchange Rate |
3, 4, 5, 6 |
Criterion Level |
70.0 to 100.0 dB |
Threshold |
70.0 to 100.0 dB |
Alarms |
2 independent with configurable indication |
Measurement Results |
Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d |
Summary Measured Values (Common to all virtual dosimeters) |
|
LωΤ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωΤMax (Lmax), LωΤMin (Lmin) where |
|
ω = A, C, or Z frequency weighting |
|
Τ = F, S, or I time weighting |
|
Lpeak, Lmax, & Lmin including time of occurrence |
|
LC-A, Exposure (Pa2s & Pa2h), Motion |
|
Exceedance count and time for 2 rms and 3 peak thresholds |
|
Overload count, duration and percentage |
|
Mechanical |
|
Display |
Color LCD 176 x 176 pixels, always on with low light sensor and front light |
Ingress Protection |
IP65 |
Weight |
130 g (4.6 oz.) including clips and windscreen |
Dimensions |
85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only |
Microphone |
¼-inch Model 375A03 |
Operating Temperature |
–10 to +50 ℃ (14 to 122 ℉) |
Operating Humidity |
Up to 90% RH, non-condensing |
1/1 Octave Filters (optional) |
|
Filters |
31.5 Hz to 8 kHz |
Event Audio Recording (optional) |
|
Format |
16-bit .wav |
Sample Rate |
8 kHz |
Recording Time |
Fixed: 2 s pre-trigger and 10 s post-trigger |
Trigger Source |
LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Spartan™ 730IS intrinsically safe noise dosimeter
There are no reviews yet.