Esco Microbiological Safety Cabinet Airstream® Plus Class II (AC2-TU) - E Series
Price:
Model | |
Manufacturer | |
Power supply | |
Weight | |
Size | |
Condition | |
Warranty |
I. Specification Esco Airstream® Plus Class II biological safety cabinets
Sentinel™ Gold Microprocessor Control System:
- There are audible and visual alarms
- Display all safety information on one screen
- The LCD display simultaneously shows time, airflow and airflow status, inlet and downflow velocities, and status comments.
- Multi-language: English, German.
- Diagnostic button, for easy checking of cabinet operating parameters and maintenance support
- The large touchpad control buttons provide good tactile feedback.
- Color-coded LEDs: green for the fan; blue for lights and sockets; and orange for the UV lamp.
- Programmable UV lamp timer extends the life of the UV lamp.
- Centered and tilted down for easy access and viewing
- Selectable Quick Start mode for quick operation.
DOUBLE energy efficient ECM DC motor:
- The most energy efficient esco Class II biological safety cabinets in the world. Energy saving with 70% energy saving compared to AC motor
- Stable airflow, despite voltage fluctuations and filter loads
- Standby mode to further reduce power consumption by 60%.
ULPA filter - H14 / Optional U15 filter:
- 10 x effect filter compared with HEPA filter
- H14 filter with 99.999% efficiency. U 15 filter with 99.9999% efficiency (10 times filter efficiency of H14 filter)
- Create an ISO Class 3 workspace instead of the industry standard ISO
- Grade 5
- Easy filter replacement process due to custom through-pass design.
Cabinet filter system:
- Ambient air is pulled through the front grille to create an inlet without entering the work surface. The inlet is joined by a downward half, to create a front air curtain that is fine-tuned to create a large performance envelope. The combined airflow passes through the rear air column towards the blower.
- About ⅓ of the air in the common room is expelled through the ULPA filter into the room. ⅔ remaining air is passed through the downflow ULPA filter and into the work area as vertical laminar flow air to create an ISO Class 3 work surface and prevent cross contamination.
- Near the work surface, the downflow separates. About half belongs to the front grille and half belongs to the rear grille. A small portion goes into the side snap areas to prevent dead air angles (small blue arrows).
- Optimized design for great performance, providing operator and product protection at wide Inflow and Downflow variations from Nominal point.
Divided work tray:
- Easy to lift and clean One-piece recessed tray available (S-Series).
Raise the armrest:
- Helps prevent grilles
- Comfortable working posture.
Motorized windows:
- Sealed window sprayer
- Window automatically stops at a safe operating height
- Conveniently move windows with your fingertips.
Unique stainless steel and glass composite wall (E-Series):
- Large corner radius for easy cleaning
- Easy access to service equipment and stores
- Stainless steel side wall available (S-Series)
- Side glass without holes for added safety.
Removable paper tray:
- Easy to clean
- Optional pre-filter can be installed.
Angled Drain Pan:
- Easy to clean
- Contains no contaminant.
Optional Hydrogen Peroxide injection port:
- Easy connection to VHP/HPV Transmitter
- Combined with front sealed window for easy decontamination.
Led light:
- Energy saving
- Lifespan is 4 times longer than fluorescent lamps.
Powder coating outside:
- Silver ion impregnated powder coat
- Inhibits microbial growth for improved safety.
RS 232 serial interface port, optional RS485 port:
- Send operational information to the Building Management System (BMS)
- Send operational information to Esco Voyager® or a Building Management System (BMS).
Isocide ™ Antibacterial Powder Coating:
- Removes 99.9% of bacteria on surfaces within 24 hours of contact.
II. Specifications Esco Microbiological Safety Cabinet Airstream® Plus Class II
TECHNICAL SPECIFICATIONS |
|||||
Glass Side: 220-240 VAC, 50/60 Hz |
AC2-3E8-TU 2011036 | AC2-4E8-TU 2011005 | AC2-5E8-TU 2010981 | AC2-6E8-TU 2011007 | |
Stainless Steel Side: 220-240 VAC, 50/60 Hz | AC2-3S8-TU 2011037 | AC2-4S8-TU 2010749 | AC2-5S8-TU 2010980 |
AC2-6S8-TU 2010943 |
|
Nominal Size |
3 ft (0.9 meter) | 4 ft (1.2 meter) | 5 ft (1.5 meter) | 6 ft (1.8 meter) | |
External Dimensions (W x D x H) | Width | 1035 (40.7") | 1340 mm (52.8") | 1645 mm (64.8") |
1950 mm (76.8") |
Depth without arm rest |
767 mm (30.2") | ||||
Depth with arm rest |
823 mm (32.4") |
||||
Height |
1400 mm (55.1") | ||||
Gross Internal Dimensions (W x D x H) | Width | 915 (36.0) | 1220 mm (48.0") | 1525 mm (60.0") |
1830 mm (72.0") |
Depth |
580 mm (22.8") | ||||
Height |
654 mm (25.7") |
||||
Usable Work Area |
0.42 m2 (4.5 sq.ft.) | 0.56 m2 (6.1 sq.ft.) | 0.71 m2 (7.6 sq.ft.) | 0.86 m2 (9.2 sq.ft.) | |
Tested Opening |
175 mm (7") |
||||
Average Airflow Velocity |
Inflow | 0.48 m/s (95 fpm) | |||
Downflow |
0.35 m/s (69 fpm) |
||||
Airflow Volume |
Inflow | 278 cmh (164 cfm) | 369 cmh (217 cfm) | 463 cmh (273 cfm) | 553 cmh (325 cfm) |
Downflow | 661 cmh (389 cfm) | 876 cmh (516 cfm) | 1099 cmh (647 cfm) |
1314 cmh (773 cfm) |
|
Exhaust |
278 cmh (164 cfm) | 369 cmh (217 cfm) | 463 cmh (273 cfm) | 553 cmh (325 cfm) | |
Required Exhaust with Optional Thimble Exhaust Collar | 320 m3/h (189 cfm) | 554 cmh (326 cfm) | 692 cmh (407 cfm) |
830 cmh (488 cfm) |
|
Static Pressure for Optional Thimble Exhaust Collar |
29 Pa / 0.11 in H2O | 38 Pa / 0.12 in H2 O | 44 Pa / 0.14 in H2 O | 50 Pa / 0.18 in H2 O | |
ULPA Filter Typical Efficiency |
>99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA |
||||
>99.999% at MPPS, H14 as per EN 1822 EU |
|||||
Sound Emission per EN 12469* | 49.6 dBA | 51.7 dBA | 53.4 dBA |
54.8 dBA |
|
LED Lamp Intensity |
E-Series | 1027 lux | 1157 lux | 1024 lux | 1249 lux |
S-Series | 1028 lux | 1193 lux | 1467 lux |
1298 lux |
|
Cabinet Construction |
Main body | 1.2 mm (0.05") 18 gauge electro-galvanized steel with white oven-baked epoxy-polyester ISOCIDE™antimicrobial powder-coated finish | |||
Work Zone |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish |
||||
Side Walls (E Series) |
UV absorbing tempered glass, 6 mm (0.2"), colorless and transparent | ||||
Side Walls (S Series) |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish |
||||
Electrical |
Cabinet Full Load Amps (FLA) | 10 | |||
Heat Load (BTU/Hr) | 597 | 682 | 785 |
938 |
|
Maximum Power Consumption (5A EOs included) (W) |
1880 | ||||
Nominal Power Consumption (W) | 175 | 200 | 245 |
287 |
|
Net Weight** |
191 Kg (421 lbs) | 236 Kg (520 lbs) | 293 Kg (645 lbs) | 351 Kg (773 lbs) | |
Shipping Weight** | 220 Kg (485) | 260 Kg (573 lbs) | 331 Kg (729 lbs) |
331 Kg (729 lbs) |
|
Shipping Dimensions, Maximum (W x D x H)** |
1100 x 880 x 1760 mm (43.3" x 34.6" x 69.3") | 1450 x 880 x 1760 mm (57.1" x 34.6" x 69.3") | 1720 x 880 x 1760 mm (67.7" x 34.6" x 69.3") | 2050 x 880 x 1760 mm (80.7" x 34.6" x 69.3") | |
Shipping Volume, Maximum** | 1.7 m3 (60.0 ft3 ) | 2.25 m3 (79.5 ft3) | 2.66 m3 (93.9 ft3) |
3.17 m3 (111.9 ft3) |
Model AC2-TU Biological Safety Cabinet Engineering Drawing:
AC2 Cabinets Save Money and Environment:
III. Accessories for Microbiological Safety Cabinet Airstream® Plus Class II (AC2-TU)
Accesories for AC2-TU Biological Safety Cabinets |
|||||
Cabinet |
Glass Side Wall | AC2-3E8-TU 2011036 | AC2-4E8-TU 2011005 | AC2-5E8-TU 2010981 | AC2-6E8-TU 2011007 |
Stainless Steel Side Wall | AC2-3S8-TU 2011037 | AC2-4S8-TU 2010749 | AC2-5S8-TU 2010980 |
AC2-6S8-TU 2010943 |
|
Exhaust Ducting |
Anti-blowback Valve 10" | ABBV-10P 5170352 | |||
Tri-safe Exhaust Collar with Alarm |
TEM-4 2010606 |
||||
Thimble Exhaust Collar |
ECO-AC23-TU 5170683 | ECO-AC24-TU 5170623 | ECO-AC25-TU 5170624 | ECO-AC26-TU 5170625 | |
Exhaust Damper |
B2-DAMPER 5170352 |
||||
Hydrogen Peroxide Decontamination Kit |
VHP In Port (Ø 1”) | VHP-IN PORT 5170552 | |||
VHP Out Top Box for Cabinet WITH Exhaust Collar Installed (Ø 1”) | VHP-ECO/OUT 3FT 5170684 | VHP-ECO/OUT 4FT 5170615 | VHP-ECO/OUT 5FT 5170616 |
VHP-ECO/OUT 6FT 5170617 |
|
VHP Out Top Box for Cabinet WITHOUT Exhaust Collar Installed (Ø 1”) |
VHP OUT TOP BOX 3ft 5170685 | VHP OUT TOP BOX 4ft 5170612 | VHP OUT TOP BOX 5ft 5170613 | VHP OUT TOP BOX 6ft 5170614 | |
Work Zone | UV Lamp | UV-15A-L 5170251 |
UV-30A-L 5170255 |
||
IV Bar |
IV-910 5170499 | IV-1215 5170231 | IV-1520 5170500 | IV-1825 5170501 | |
Multiple Piece Tray Option (for AC2-S-TU) | SDT-AC2-3E-TU 5021057 | SDT-AC2-4E-TU 5020830 | SDT-AC2-5E-TU 5020976 |
SDT-AC2-6E-TU 5020828 |
|
Single Piece Tray Option (for AC2-E-TU) |
SGT-AC2-3S-TU 5021103 | SGT-AC2-4S-TU 5020973 | SGT-AC2-5S-TU 5020978 | SGT-AC2-6S-TU 5020981 | |
Pre-filter on Paper Catch | PF-41 5090061 | PF-42 5090062 | PF-43 5090063 |
PF-44 5090064 |
|
Electrical Outlet |
Direct Mounted | EO-H_ | |||
Service Fixtures | EU SF-Gas-20 mm and Solenoid Valve |
SF-1G20 5170410 and SL-VALVE 5070086 |
|||
EU SF-Vacuum-20 mm |
SF-1V20 5170457 | ||||
EU SF-Air-20 mm |
SF-1A20 5170502 |
||||
EU SF-Nitrogen-20 mm |
SF-1N20 5170503 |
||||
EU SF-Water-20 mm |
SF-1W20 5170458 | ||||
EU SF-Universal-22 mm |
SF-2U22 5170504 |
||||
Support Stands, Ships Flat |
Fixed Stand with Leveling Feet, 28” height | SAL-3A0 Gen 2 5130170 | SAL-4A0 Gen 2 5130134 | SAL-5A0 Gen 2 5130171 | SAL-6A0 Gen 2 5130172 |
Fixed Stand with Leveling Feet, 34” height | SAL-3B0 Gen 2 5130174 | SAL-4B0 Gen 2 5130175 | SAL-5B0 Gen 2 5130176 |
SAL-6B0 Gen 2 5130177 |
|
Fixed Stand with Caster Wheels, 28” height | SPC-3A0 Gen 2 5130155 | SPC-4A0 Gen 2 5130152 | SPC-5A0 Gen 2 5130162 | SPC-6A0 Gen 2 5130154 | |
Fixed Stand with Caster Wheels, 34” height |
SPC-3B0 Gen 2 5130165 | SPC-4B0 Gen 2 5130166 | SPC-5B0 Gen 2 5130167 | SPC-6B0 Gen 2 5130168 | |
Telescopic Stand with Leveling Feet, 1” adjustment | STL-3A0 5130050 | STL-4A0 5130051 | STL-5A0 5130052 |
STL-6A0 5130053 |
|
Telescopic Stand with Caster Wheels, 1” adjustment |
STC-3A0 5130055 | STC-4A0 5130056 | STC-5A0 5130057 | STC-6A0 5130058 | |
Motorized Height Stand with Caster Wheels, 39.5” height | SPM-3A_ | SPM-4A_ | SPM-5A_ |
SPM-6A_ |
|
Misc |
IQ/OQ Protocol |
9010179 |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Esco Microbiological Safety Cabinet Airstream® Plus Class II (AC2-TU) – E Series