PCE-HDM 20 digital multimeter

Price: Liên hệ

Model PCE-HDM 20
Manufacturer PCE
Power supply
Weight
Size
Condition Còn hàng
Warranty 12 tháng

I. Specification of PCE-HDM 20 digital multimeter

Infrared camera - TRMS digital multimeter for current, voltage, power, frequency and resistance / CAT IV 600 V / CAT III 1000 V / With infrared non-contact temperature measurement / MAX, MIN and HOLD functions.

PCE-HDM 20 digital multimeter
  • The PCE-HDM 20 power meter infrared imaging camera is a universal measuring instrument.
  • The PCE-HDM 20 digital multimeter enables a wide range of measurement projects. This makes it easy for users to investigate current, voltage, capacitance, frequency, and resistance. In addition to these measurements, the infrared imaging camera can also perform measurements such as duty cycle, diode test, and continuity test.
  • In addition to electrical parameters, the PCE-HDM 20 infrared imaging camera can also be used for temperature determination. The determination of temperature can be done in two different ways. In the first case, the temperature can be measured by plugging in the thermocouple. In the second case, the infrared imaging camera provides non-contact temperature measurement. For this purpose, an infrared lamp is installed on the infrared imaging camera, thus allowing the temperature to be determined from a distance. The thermal image is then clearly displayed on the screen.
  • For a closer look, there are five different color palettes available, which can be selected as desired. To measure temperature by infrared sensor, the lamp helps to make darker areas brighter.

PCE-HDM 20 digital multimeter PCE-HDM 20 digital multimeter PCE-HDM 20 digital multimeter

II. Advantages

  • Auto off
  • 2.8" LCD screen
  • Built-in thermal imaging camera
  • Thermal measurement via IR or thermocouple
  • Measure resistance and check continuity
  • Test diodes and measure capacitance.

infrared thermal camera infrared thermal camera infrared thermal camera

III. Standard package

PCE-HDM 20 digital multimeter
  • Infrared imaging camera - PCE-HDM 20 digital multimeter
  • 2 Measuring lines
  • K-type thermocouple probe Type K
  • Li-ion battery
  • Charger
  • Power socket
  • 3 Plugs for power plugs
  • Micro-SD Card (8 GB)
  • Magnet
  • Cloth ring
  • Temperature adapter
  • User manual.
***See more of GMGA digital power meters at: https://gmga.vn/en/danh-muc/measuring-device/power-gauges/

IV. Specifications of PCE-HDM 20 digital multimeter

Temperature measurement with thermal imaging camera

Sampling rate

3 times per second
Field of view (FOV)

21° x 21°C / 0.5 m / 1 ft 7.6"

Spatial resolution (IFOV)

4.53 mrad
Resolution infrared camera

80 x 80 Pixel

Thermal sensitivity / NETD

<0.1°C (0.18°F) at 30°C (86°F) / 100 mK
Frame rate

50 Hz

Focal length

7.5 mm
Sensor type

uncooled microbolometer

Spectral range

8 ... 14 µm
Measuring range object temperature

-20 ... 260°C / -4 ... 500°F

Measurement accuracy

± 3°C / 5.4°F or 3% of the measured value, at 10 ... 35°C /  50 ... 95°F ambient temperature and > 0°C / 32°F object temperature

General Technical Data

Display

Colour TFT, 6000 points with status display
Conversion

TRMS

Reference standards

IEC/EN61010-1, IEC/EN61326-1
Isolation

Double

Pollution degree

2
Overload category

CAT IV 600 V, CAT III 1000 V

Battery type

1 x 7.4V Li-Ion battery, 2300-mAh
Power supply charger

100 / 240V AC, 50/60 Hz, 10V DC, 1 A

Battery level indicator

Yes
Automatic shutdown

After 15, 30 or 60 minutes of inactivity (deactivatable)

Fuses

F10A/1000V, 10 x 38 mm (Input 10 A)

F800mA/1000V, 6 x 32 mm (Input mA, µA)

Test temperature

18 ... 28°C / 64 ... 82°F
Operating conditions

5 ... 40°C / 41 ... 104°F, <80% r.H.

Storage conditions

-20 ... 60°C / -4 ... 140°F, <80% r.H.
Maximum operating height

2000 m / 2187 yd

Dimensions

175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in
Weight

540 g / 1 lb 3oz

Technical Data DC Voltage

Measuring range

Resolution Measurement accuracy Input resistance Overload protection
600 mV 0.1 mV ± (0.2% of measurement value + 5 Dgt) >10 MΩ

1000V DC / ACrms

6V

0.001V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
60V 0.01V ± (0.2% of measurement value + 5 Dgt) >10 MΩ

1000V DC / ACrms

600V

0.1V ± (0.2% of measurement value + 5 Dgt) >10 MΩ 1000V DC / ACrms
1000V 1V ± (0.2% of measurement value + 5 Dgt) >10 MΩ

1000V DC / ACrms

Technical Data AC Voltage (TRMS)

Measuring range

Resolution Measurement accuracy Measurement accuracy

Overload protection

(50 ... 60 Hz)

(61 Hz ... 1 kHz)

6V

0.001V ± (0.8% of measurement value +5 Dgt)± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
60V 0.01V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt)

1000V DC / ACrms

600V

0.1V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
1000V 1V ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt)

1000V DC / ACrms

Technical Data DC and AC voltage (TRMS)

Measuring range

Resolution Measurement accuracy Input resistance Overload protection
6V 0.001V ± (2.4% of measurement value +20 Dgt) >10 MΩ

1000V DC / ACrms

60V

0.01V ± (2.4% of measurement value +20 Dgt) >10 MΩ 1000V DC / ACrms
600V 0.1V ± (2.4% of measurement value +20 Dgt) >10 MΩ

1000V DC / ACrms

1000V

1V ± (2.4% of measurement value +20 Dgt) >10 MΩ

1000V DC / ACrms

Technical Data Direct Current

Measuring range

Resolution Measurement accuracy Overload protection
600 µA 0.1µA ± (0.9% of measurement value +5 Dgt)

Protection 800-mA / 1000 V

6000 µA

1 µA ± (0.9% of measurement value +5 Dgt) Protection 800-mA / 1000V
60-mA 0.01-mA ± (0.9% of measurement value +5 Dgt)

Protection 800-mA / 1000V

600-mA

0.1-mA ± (0.9% of measurement value +8 Dgt) Protection 800-mA / 1000V
10:00 AM 0.01 A ± (1.5% of measurement value +5 Dgt)

Protection 10 A / 1000V

Technical Data Alternating Current (TRMS)

Measuring range

Resolution Measurement accuracy Overload protection
600 µA 0.1 µA ± (1.2% of measurement value +5 Dgt)

Protection 800-mA / 1000V

6000 µA

1 µA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V
60-mA 0.01-mA ± (1.2% of measurement value +5 Dgt)

Protection 800-mA / 1000V

600-mA

0.1-mA ± (1.2% of measurement value +5 Dgt) Protection 800-mA / 1000V
10:00 AM 0.01 A ± (1.5% of measurement value +5 Dgt)

Protection 10 A / 1000V

Technical Data Coil Current

Measuring range

Resolution Measurement accuracy Measurement accuracy (61 Hz ... 1 kHz)

Overload protection

(50 ... 60 Hz)

30 A

0.01 A ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt) 1000V DC / ACrms
300 A 0.1 A ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt)

1000V DC / ACrms

3000 A

1:00 AM ± (0.8% of measurement value +5 Dgt) ± (2.4% of measurement value +5 Dgt)

1000V DC / ACrms

Technical Data Diode Test

Test current

<1.5-mA
Maximum voltage at the open circuit

3.3V DC

Resistance and continuity test

Measuring range

Resolution Measurement accuracy Acoustic warning sound Overload protection
600 Ω 0.1Ω ± (0.5% of measurement value +10 Dgt) >50 Ω

1000V DC / ACrms

6 Ω

0.001 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
60 kΩ 0.01 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω

1000V DC / ACrms

600 kΩ

0.1 kΩ ± (0.5% of measurement value +5 Dgt) >50 Ω 1000V DC / ACrms
6 MΩ 0.001 MΩ ± (0.5% of measurement value +5 Dgt) >50 Ω

1000V DC / ACrms

60 MΩ

0.01 MΩ ± (2.5% of measurement value +10 Dgt) >50 Ω

1000V DC / ACrms

Technical Data Frequency

Measuring range

Resolution Measurement accuracy Overload protection
40 Hz ... 10 kHz 0.01 Hz ... 0.001 kHz ± (0.5% of measurement value)

1000V DC / ACrms

60 Hz

0.01 Hz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms
600 Hz 0.1 Hz ± (0.09% of measurement value +5 Dgt)

1000V DC / ACrms

6 kHz

0.001kHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms
60 kHz 0.01kHz ± (0.09% of measurement value +5 Dgt)

1000V DC / ACrms

600 kHz

0.1 kHz ± (0.09% of measurement value +5 Dgt) 1000V DC / ACrms
6 MHz 0.001 MHz ± (0.09% of measurement value +5 Dgt)

1000V DC / ACrms

10 MHz

0.01 MHz ± (0.09% of measurement value +5 Dgt)

1000V DC / ACrms

Technical Data Duty Cycle

Measuring range

Resolution Measurement accuracy
5 ... 95% 0.10%

± (1.2% of measurement value +2 Dgt)

Technical Data Capacitance

Measuring range

Resolution Measurement accuracy Overload protection
60 nF 0.01 nF ± (1.5% of measurement value +20 Dgt)

1000V DC / ACrms

600 nF

0.1 nF ± (1.2% of measurement value +8 Dgt) 1000V DC / ACrms
6 µF 0.001 µF ± (1.5% of measurement value +8 Dgt)

1000V DC / ACrms

60 µF

0.01 µF ± (1.2% of measurement value +8 Dgt) 1000V DC / ACrms
600 µF 0.1 µF ± (1.5% of measurement value +8 Dgt)

1000V DC / ACrms

6000 µF

1 µF ± (2.5% of measurement value +20 Dgt)

1000V DC / ACrms

Technical Data Temperature (Thermoelement Type K)

Measuring range

Resolution Measurement accuracy Overload protection
-40 ... 600°C / -40 ... 1112°F 0.1°C / 0.18°F ± (1.5% of measurement value 3°C / 5.4°F)

1000V DC / ACrms

600 ... 1000°C / 1112°F ... 1832°F

1°C / 1.8°F ± (1.5% of measurement value 3°C / 5.4°F)

1000V DC / ACrms

  ***Video of digital multimeter - infrared thermal camera is available at: Gmga Measuring Youtube.

Review PCE-HDM 20 digital multimeter

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review PCE-HDM 20 digital multimeter
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide