Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
Price: Contact
Model | NMS-SE-831C |
Manufacturer | LARSON DAVIS (a part of the PCB PIEZOTRONICS) |
Power supply | N/A |
Weight | N/A |
Size | N/A |
Condition | Stocking |
Warranty | 12 months |
Need a Portable outdoor noise monitoring system that you can deploy outdoors, collect measurement data, and then retrieve for analysis?
I. Specifications of Portable outdoor sound monitoring system Larson Davis SoundAdvisor™ NMS-SE-831C
Powered with SoundAdvisor Sound Level Meter Model 831C, Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C with 831C-SR firmware is a rugged, portable solution that can make sound recordings for easier noise source identification.
Powered via 8 D-cell battery pack, the SoundAdvisor™ NMS-SE-831C can continuously make measurements for one week.
- Ideal to deploy, measure, download, then analyze
- Records sound for noise source identification*
- Includes SoundAdvisor Sound Level Meter Model 831C.
(* Sound recording requires 831C-SR firmware option.)
APPLICATIONS
- Mining Operations Noise Monitoring
- Construction Site Noise Monitoring
- Wind Turbine Noise Monitoring
- Entertainment Venue Noise Monitoring
- Unattended Noise Monitoring.
II. Firmware for Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
From Octave Band Analysis to Event Detection and Alerts
REVERBERATION TIME MEASUREMENTS
Model: 831C-RA
- Reverberation times are used in architectural acoustics applications ranging from simple experimental reverberation time determination for room performance, to calculating absorption coefficients for material performance. SoundAdvisor™ with 831C-RA firmware measures decays and then computes reverberation time according to ISO or ASTM standards. When using the Interrupted Noise method, the SoundAdvisor not only triggers the data acquisition, but its built-in Noise Generator can be used to drive the omni-directional sound source. Integrated Impulse method is also available. Measurements can be made using 1/3 octaves or full octave bands. The meter computes the decay times automatically, shows the T20 and T30 spectra superimposed, computes seven (7) quality indicators per frequency, and grades the measurement data.
- The resulting data and decays can be exported to the G4 LD Utility or can be processed further in DNA for reverberation time, absorption coefficients, or sound insulation calculations.
MEASURED SOUND RECORDING
Model: 831C-SR
- Measuring sound levels is a well-accepted way to objectively quantify the noise radiated by a product in an environmental survey. Rather than rely simply on the objective data, why not record a sample of the sound to truly determine the source of the noise?
- The firmware 831C-SR option enables the SoundAdvisor to record audio files in a raw format (.wav) for lossless recording or with .ogg compression to reduce file size. Listen live or to recordings from the meter, or listen to recordings from G4 LD Utility Software or LD Atlas Mobile App. Record audio of automatically triggered events, at the beginning of each Measurement history, manually, or with logic level input.
OCTAVE BAND ANALYSIS
Model: 831C-OB3
- In many applications, it is important to acquire both the broadband level and spectral content of noise data. With spectral information, the source and content of the measured level can be better understood. Constant percentage bandwidth filters (1/1 or 1/3 octave) best approximate human perception of sound.
- Option 831C-OB3 firmware enables simultaneous real-time measurement of 1/1 and 1/3 octave Leq, Lmax, Lmin along with all the ANY LEVEL™ broadband parameters. Option 831C-OB3 is compliant with IEC 61260:2014 Class 1 and ANSI S1.11-2014 Class 1 standards covering the entire frequency range of human hearing: 6.3 Hz to 20 kHz for 1/3 octave bands.
- When 831C-OB3 is combined with Time History Logging (831C-LOG) or Automatic Event Detection and Event History (831C-ELA), it is possible to review the frequency content of logged data or specific events.
FFT SOUND AND VIBRATION ANALYSIS
Model: 831C-FFT
When higher frequency resolution than 1/3 octaves is needed, FFT Frequency Analysis Model 831C-FFT is the ideal solution. The narrow-band filtering provided by Fast Fourier Transform (FFT) Analysis of single-channel acoustic or vibration sources is useful for machinery analysis, product development, source detection, tonality measurement, fault analysis, and vibration troubleshooting. Offering precision spectral analysis of signals, FTT acquisition settings can be adjusted to visualize specific acoustic and vibration phenomena. Using FFT on the handheld Larson Davis SoundAdvisor™ 831C Sound level meter is a convenient way to achieve an objective measurement of tones or vibration phenomena in the field.
Tonality Standards Supported
- ISO/PAS 20065:2016
- ISO 1996-2:2007 Annex C
- ISO 1996-2:2017 (ISO/PAS 20065).
ACOUSTIC PARAMETER LOGGING
Model: 831C-LOG
The Sound level meter Larson Davis SoundAdvisor™ 831C can be used to record the evolution of sound pressure level over time as a Time History (TH). The Time History is then used to profile the observation period, which can vary from several seconds to continuous monitoring.
With the addition of Time History Logging Firmware (831C-LOG), users can pre-select from logging periods as small as 20 ms to a full 24 hours. Parameter selections consist of familiar acoustic metrics as well as non-acoustic metrics, such as battery condition, outdoor microphone performance, and meteorological data (831C-WTHR).
LOGGED FOR OBA FILTER
(Selected Frequency and Time Weighting Parameters for 1/1 and 1/3 Octaves)
- Leq
- Lmin
- Lmax.
LOGGED FOR A, C, AND Z WEIGHTINGS (VARIABLE W)
- Lweq
- Lwpeak
- LwSmax
- LwFmax
- LwImax
- LwSmin
- LwFmin
- Lwlmin
- LwS
- LwF.
OTHER PARAMETERS
- LCeg - LAeg
- LIeg - LAeg
- Statistics (Ln)
- Battery
- Temperature
- External Power
- Wind Speed
- Gust Direction
- Gust Speed
- Avg Temp
- Max Temp
- Min Temp
- Avg Humidity
- Max Humidity
- Min Humidity.
MEASUREMENT HISTORY
Model: 831C-ELA
- While Time Histories are typically logged at one sample per second, longer- term averages are often useful to see trends, e.g., 10 minute or hourly averages. 831C-ELA firmware enables Measurement History (MH) and logs these parameters similar to Time History (TH) over a longer interval time. MH and TH can run together simultaneously or independently.
- Data for each measurement or location is saved in a unique MH record and may include the Leq, Lmax, Lmin, SPL, and statistical distribution of the SPL (Ln). A complete set of MH records then can be stored in a single measurement that keeps all the noise survey data in a single file. Finally, an automated sound recording at the beginning of each MH period can be achieved with 831C-SR firmware.
DATA |
PARAMETERS |
NOTES |
||
Averages |
Leq |
LE |
|
|
Sound |
Lmax |
Lmin |
Lpeak |
|
Occurrence Date |
Lmax |
Lmin |
Lpeak |
|
Temperature |
Avg |
Max |
Min |
|
Relative Humidity |
Avg |
Max |
Min |
|
Wind Speed |
Avg |
Max |
Min |
|
1/3 Octaves |
Leq |
Lmax |
Lmin |
w/ 831C-OB3 |
1/1 Octaves |
Leq |
Lmax |
Lmin |
w/ 831C-OB3 |
Date & Time |
Date |
Time |
|
|
Measurement Time |
Run Duration |
Run Time |
Pause Time |
|
GPS |
Lat |
Lon |
Elevation |
w/ GPS002 |
Other |
Exceedance |
6 Ln |
|
|
AUTOMATIC EVENT DETECTION AND ALERTS
Model: 831C-ELA
In Sound level meter Larson Davis SoundAdvisor™ 831C, events are defined as one of the following:
- Exceedance of a fixed threshold level for a minimum duration
- Exceedance of a dynamic threshold level for a minimum duration
- External trigger set by the digital input signal.
With 831C-ELA firmware, event definition is defined by you – including threshold level, duration, and event continuation period when the SPL drops below the threshold level for a specific period of time. Triggering status icons identify event progression and qualification (see graph above).
SoundAdvisor™ 831C can automatically generate an email alert to provide fast notice of any noise exceedance. The event alerts can be sent to a user configurable list of email addresses or by text message using an email to MMS gateway. Email event sound recording in conjunction with option 831C-SR.
ADDED FUNCTIONALITY WITH 831C-ELA OPTION |
|
With Option |
Description |
831C-OB3 |
Frequency analysis of the event |
831C-LOG |
Record an independent time history of the event including filters when |
831C-SR |
Record event audio in .wav or compressed file |
NOISE MONITORNING SCHEDULING TOOLS
Model: 831C-SCH
- Data and alerts are often needed only on certain days or specific times. With 831C-SCH firmware, schedule run/stop times, modem usage, and alert type and recipient. Together with the optional event feature, 831C-ELA, trigger levels and alert recipient can be adjusted for time of day or day of the week. In conjunction with 831C-SW firmware, schedule power to the modem - conserve power when the modem is not needed.
- With the graphical interface in G4 LD Utility software, easily configure SoundAdvisor™ 831C to measure and report only what you need, even when those needs change.
Example of an 831C-SCH schedule with daily Run/Save times (green), two alert recipients on weekdays (orange), three alert levels (red), a special weekend schedule, and the modem “waking up from” low power consumption mode every weekday evening (purple).
CELLULAR COMMUNICATION
Model: 831C-SW
- We understand how beneficial it can be to have access to your noise monitor at any time of the day. Due to the remoteness or need to setup contracts and get permits, connecting a noise monitor to a wired network or main power just isn’t feasible.
- With option 831C-SW you can connect the Sound meter Larson Davis SoundAdvisor™ 831C by USB directly to a Sierra Wireless gateway and get a highly portable noise monitor that can easily be powered by battery and/or solar. We recommend the Sierra Wireless model RV50X because of its low power usage and industrial design.
III. Software solutions for Portable sound monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
SoundAdvisor™ NMS-SE-831C has numerous on-board capabilities, yet often further processing, visualization, or reporting needs exist. For this purpose the Sound meter SoundAdvisor™ NMS-SE-831C can be used as a portable instrument and retrieve the data, work as a data acquisition front-end, or in combination with other products.
G4 LD UTILITY SOFTWARE
With G4, connect, control, download, and view data from multiple devices simultaneously. Organize files and meters by project. View data, generate reports, and easily export in Excel® format for further data analysis. Examine graphs of multiple parameters and heat maps of octave band data. G4 is compatible with Models 831C, 831, LxT, HVM200, 730, 730-IS, Series 821ENV and 821IH.
- Store measurement set-ups for use on one or more Sound Level Meters
- Download data to PC and export to Excel® for further analysis
- Connect to 831C-based meters and noise monitoring systems via USB, Ethernet, or cellular connection
- Manage multiple noise meters and systems with simple and convenient project and file management
- View time history data in graphical format
- Listen to audio recordings
- View Sound Level Meter screen on your PC – ideal for presentations or training.
LD Atlas™ MOBILE DEVICE APPLICATION
- Install the free LD Atlas on your phone or tablet – iOS or Android – and connect to your SoundExpert™ Sound Level Meter 821ENV, Spartan™ Sound Level Meter Series 821IH, Spartan™ Noise Dosimeter Model 730, SoundAdvisor™ Sound Level Meter Model 831C, and Human Vibration Meter Model HVM200.
DATA SERVICE WEB-BASED NOISE MONITORING
- Data Service is a cloud-based tool that provides both public access to noise levels and easy access to in-depth historical noise data and reports.
- Data Service collects data from Larson Davis SoundAdvisor™ 831C noise monitors and presents the information in a format accessible and appropriate for all stakeholders.
SoundLink SOFTWARE SERVICES
- SoundLink Service enables remote access worldwide. This solution reduces labor costs, simplifies data gathering, and allows for remote status monitoring and quick responses to noise concerns. SoundLink is compatible with Model 831C, NMS044, and NMS045.
DATA NAVIGATION AND ANALYSIS SOFTWARE (DNA)
Data Navigation and Analysis Software (SWW-DNA) is designed to analyze and report environmental noise, worker exposure, and architectural acoustic measurements with an interactive graphical interface. With many sound studies being similar in nature, a drag- and-drop feature places new data in an existing layout that allows for quick, professional-looking reports. DNA can either retrieve existing files from Model 831C, or can drive the 831C as a data acquisition front-end.
- Remote network access
- Interactive graphs with data: zoom, overlay Time History and spectrogram with playable event sound recordings, advanced event analysis, mapping, industrial hygiene, and more.
- Template-based operation with customizable options.
SOFTWARE DEVELOPMENT KIT (831C-SDK)
- Build your own software or integrate the SoundAdvisor into your existing application using our Software Development Kit (SDK).
- The Software Development Kit for the Sound level meter Larson Davis SoundAdvisor™ 831C interfaces smoothly and directly with Microsoft® or Linux® programming environments supporting Excel®, HTML5, Javascript, Visual C++, or C# programming languages. The SDK provides functionality to connect and fully control the Model 831C over USB, network, or wireless gateway (modem) connections. File download is supported and the SDK includes documentation and software for extracting data from files. With JSON (JavaScript Object Notification), the SDK makes it easy to create modern, web-based applications with minimal effort.
IV. Ordering information of Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
Model Number |
Description |
Sound Level Meter |
|
831C-FF |
SoundAdvisor Model 831C sound level meter with Class-1 free-field, pre-polarized precision condenser microphone (50 mV/pa), preamplifier (PRM831), accessory kit (831C-ACC) |
831C-FF-KIT1 |
831C-FF with DVX012 and firmware options 831C-LOG, 831C-OB3, 831C-ELA & 831C-SR |
831C-FF-KIT2 |
SoundAdvisor Model 831C-FF with firmware options 831C-LOG & 831C-OB3 |
831C-RI |
SoundAdvisor Model 831C sound level meter with Class-1 random-incidence pre-polarized condenser microphone (50 mV/Pa), preamplifier (PRM831), accessory kit (831C-ACC) |
831C-RI-KIT1 |
SoundAdvisor Model 831C-RI with DVX012 and firmware options 831C-LOG, 831C-OB3, 831C-ELA & 831C-SR |
831C-LOWN |
SoundAdvisor Model 831C sound level meter with 378A04 low noise, ICP® microphone and preamplifier (450 mV/Pa), accessory kit (831C-ACC) and ICP adapter (ADP074) |
831C-ENV |
SoundAdvisor Model 831C class 1 sound level meter base kit for environmental noise. Includes EPS2116, PRM2103-FF, CBL203-20 & PSA032 and firmware options 831C-LOG, 831C-OB3, 831C-ELA, 831C-SR & 831C-SW |
831C |
SoundAdvisor Model 831C sound level meter for environmental and community noise without microphone or preamplifier |
Firmware Options |
|
831C-LOG |
Upgrade Model 831C sound level meter with logging of time histories with periods from 20 ms to 24 hr |
831C-OB3 |
Upgrade Model 831C sound level meter with Real-time 1/1 & 1/3 octave filter set |
831C-ELA |
Upgrade Model 831C sound level meter with event, interval and daily histories logging |
831C-SR |
Upgrade Model 831C to record compressed and uncompressed audio |
831C-MSR |
Upgrade Model 831C to add Measurement History and sound recording |
831C-SW |
Upgrade Model 831C to add direct USB communication with Sierra Wireless RV50 gateway |
831C-FFT |
Upgrade Model 831C to add FFT Analysis and tonal assessment |
831C-RA |
Upgrade Model 831C to add Room Acoustic measurement capability |
831C-SCH |
Upgrade Model 831C to add scheduling for measurements, communication options, and alert levels |
Calibration |
|
CER-831 |
ISO 17025 compliant calibration and certification of 831C (SLM, preamplifier with microphone) and 831C-RPT |
CER-831-E |
Environmental certification Model 831C for [-40,+158] °F ([-40,+70] °C) range. Includes calibration of 831C and PRM831, 831-RPT, environmental test of microphone. Microphone calibration not included. |
CER-MIC |
Calibration and certification for microphone |
CER-PRM2103-E |
Environmental Certification Model PRM2103 for [-40,+158] °F ([-40,+70] °C) range; (no microphone certification); environmental test of microphone |
831-RPT |
Model 831C Sound Level Meter certification test report. Certificate for SLM, preamplifier, and microphone. |
Accessories |
|
831C-ACC |
Accessory kit for Model 831C sound level meter, which includes case (831-CCS), batteries (4-AA), power supply w/ USB cable (PSA029), WiFi dongle (DVX014), and windscreen (WS001) |
831-CCS |
Hard shell case with rugged foam lining |
831-MEM32G |
USB memory, 32GB |
ADP074 |
Adapter to provide ICP output on BNC connector |
ADP097 |
Direct input adapter with BNC connector for Model 831C & 831 sound level meters |
BAT015 |
8 D cell battery holder with fuse; batteries not included |
CBL138 |
Cable USB A to mini-B 6 ft (1.8 m) |
CBL139 |
AC/DC output cable with 2.5 mm sub-miniature plug to BNC or RCA |
CBL140 |
DC power cable for Model 831 Sound Level Meter, 10 - 25 VDC includes lead-acid battery clamps and 12 V car plug |
CBL170 |
Cable connecting Model 831 to 9-pin D connector (wind speed, direction, logic I/O, 3 slow ADC) and coaxial DC connector (to PSA027) |
DVX018 |
USB Adaptor to serial (DB9 connector) |
DVX012 |
USB to Ethernet adapter |
DVX013 |
Gigabit Ethernet dongle for 831C with USB-A connector to RJ-45 (CAT5) and includes 3 port USB hub. Hub requires external 5V power, AC adapter included (StarTech model ST3300GU3B). For DC power use PSA036 |
DVX014 |
WiFi adapter supporting b/g/n for 831C (D-Link DWA-121) |
DVX015 |
USB self-powered 2 port hub (Cables To Go model #29525) |
EXC006/10/20/50 |
Microphone extension cable, 5 pin Switchcraft, 6 ft (2 m), 10 ft (3 m), 20 ft (6 m), 50 ft (15 m). Additional lengths available |
GPS002 |
USB connected GPS receiver |
PSA029 |
AC Power supply (100-240 VAC to 5 V USB w/mini-B cable, CBL138) |
PSA036 |
12V to 5V DC power adapter for use with DVX013 |
SEN025 |
Single axis accelerometer, 10 mV/(m/s2) or 100 mV/g ICP. |
WS001 |
3.5 inch diameter windscreen for 0.5 inch microphone |
Microphones and Preamplifiers |
|
377B02 |
0.5inch free-field, prepolarized condenser microphone, typical sensitivity = 50 mV/Pa, 3.15 Hz to 20 kHz (±2 dB) |
377C20 |
0.5 inch random incidence, prepolarized condenser microphone 50 mV/Pa, 3.15 Hz to 16 kHz (±2 dB) |
377C10 |
0.25 inch pressure, prepolarized condenser microphone typical sensitivity = 1.6 mV/Pa, 4 Hz to 70 kHz (±2 dB) |
378A04 |
ICPr Low noise microphone & preamplifier system, 6.5 dB A-weighted typical noise |
ADP043 |
0.25 inch microphone to 0.5 inch preamplifier adaptor |
PRM831 |
Model 831C Sound Level Meter preamplifier for 0.5 in free-field or random incidence prepolarized microphones |
PRM2103-FF |
Permanent Outdoor Preamplifier with free-field microphone with Remote Calibration Check, humidity reading and heater, for pre-polarized microphone. Random or 90 degree response can be selected on the Model 831C. |
Software |
|
SWW-SLM-UTILG4 |
G4 LD Utility software for SoundTrack® LxT and Model 831C sound level meter: download, upgrade, translate, print text reports or export to spreadsheet. CD with Quick Start Guide |
SWW-DNA |
Basic software and dongle (USB) for evaluation and reporting of data downloaded from the Larson Davis instruments, requires an instrument driver |
SWW-DNA-831 |
Instrument driver for instrument control, set-up, live display, data translation, and data download for Model 831C & 831 sound level meter |
SWW-DNA-EV |
DNA option for Events tracking: PNL and PNLT Event Time History and EPNL Event |
SWW-DNA-BA |
DNA software Building Acoustics, allows calculation of transmission loss and sound insulation calculations |
SWW‑DNA‑REMOTE |
DNA software for monitoring a remote location when using 820, 824, 870, or 831C Models. Uses modem connection for communication and data download. |
Calibrators |
|
CAL200 |
Class 1 acoustic calibrator with user selectable output of 94 or 114 dB at 1 kHz. 1/2 inch opening (no adaptor) |
CAL250 |
Class 1 microphone calibrator, output 114 dB at 251.2 Hz. 1 inch opening with 1/2 inch (ADP019) adaptor. 3/8 inch (ADP020) and 1/4 inch (ADP021) adaptors available |
Noise Monitoring System Components |
|
COM-RV50-DC-E/U |
Sierra Wireless Model RV50 cellular gateway to add Internet connectivity through cellular network to 831C. Choose /U for US and /E for rest of world. Requires option (831C-SW for direct USB connection). |
EPS030-831 |
Case for Model 831C Sound Level Meter including (1) 21 Ah battery, charger (PSA032), internal preamplifier cable (CBL141), and power distribution cable (CBL151) |
EPS036-831 |
Case on wheels (CCS035) to enclose Model 831C with (2)x 21 Ah batteries (BAT011). Includes CBL166 & CBL168 to power Model 831C |
EPS037-831 |
Case on wheels (CCS035) to enclose Model 831C with 100 Ah batteries (BAT012). Includes CBL166 & CBL168 to power Model 831C |
EPS042 |
Environmental protection for 831C, 831 or LxT with BAT015 in a CCS002 hard case; includes a cable gland |
EPS044 |
Noise monitor enclosure for 831C including CCS051, CCS052, ACC009, PSA038, CBL224-02, CBL225-01, CBL226-02 & CBL228-03 |
EPS044-SLA |
Noise monitor enclosure for 831C including CCS051, CCS052, BAT020 35 Ah SLA battery, ACC009, PSA038, CBL224-02, CBL225-01, CBL226-02 & CBL228-03 |
EPS044-LFP |
Noise monitor enclosure for 831C including CCS051, CCS052, BAT019 45 Ah LiFePo battery, ACC009, PSA038, CBL224-02, CBL225-01, CBL226-02 & CBL228-03. License required to ship battery |
EPS2116 |
Environmental protection for 1/2 inch preamplifiers with windscreen, bird spikes, desiccants, and universal mounting |
SEN031 |
Combined weather sensor: wind speed and direction (no moving parts), temperature, humidity, pressure, rainfall (requires CBL167 cable + DVX008A) |
TRP001 |
Instrumentation tripod with ADP032 preamplifier to tripod interface |
TRP003 |
Support tripod, maximum height 8 ft (2.4 m) used in portable NMS systems |
CBL174 |
Waterproof cable connecting EPS030-831 to external PC, 2 m USB A-to-B |
ACC009 |
Monopole for use in EPS044 and NMS044 systems |
BAT019 |
45 Ah 12V LiFePo battery. Weighs 12.8 pounds (5.8 kg) |
BAT020 |
35 Ah 12V SLA battery. Weighs 24.7 pounds (11.2 kg) |
CBL218 |
Cable, USB-A to micro-B, 3 ft (1 m) |
CBL222-08 |
Cable connecting 831C or 831 to PRM2103 with Anderson Powerpole® connectors for 12V power. (8 ft / 2.4 m) |
CBL222-20 |
Cable connecting 831C or 831 to PRM2103 with Anderson Powerpole connectors for 12V power. (20 ft / 6 m) |
CBL223-02 |
Power cable for Sierra Wireless with sense line and Anderson Powerpole connectors for 12V power (2 ft / 0.6 m) |
CBL224-02 |
Power cable for 831C or 831 with Anderson Powerpole connectors for 12V power (2 ft / 0.6 m) |
CBL225-01 |
Power cable for battery with spade connectors and Anderson Powerpole connectors for 12V power (1 ft / 0.3 m) |
CBL226-02 |
Power cable with Anderson Powerpole connectors to bare wires (2 ft / 0.6 m) |
CBL228-03 |
Cable, 1m, with MC-4 connectors for solar and bare wires for use with solar charge controllers |
CCS051 |
Base enclosure for EPS044 and NMS044 systems that includes mounting plate, glands and mount for ACC009 |
CCS052 |
Canvas bag with zipper and handles. 19 x 9 x 6 in (48 x 23 x 15 cm) |
COM-ANT-GPS |
GPS antenna with SMA connector and cable for use Sierra Wireless modem like RV-50 |
SLP001 |
Portable folding 60 Watt solar panel with integrated stand and carrying case |
SLP002 |
Portable folding 100 Watt solar panel with integrated stand and carrying case |
PSA038 |
Solar charge controller, 10A, used in EPS044 and NMS044 configurations |
PSA039 |
AC power supply, 15 V, 90 W, with MC4 connectors for use with EPS044 & NMS044 |
PSA040 |
SLA Battery Charger with PowerPole output connectors. Input: 100-240VAC, 50-60Hz, 0.80-035A. Output: 14.7VDC, 2.25A |
Noise Monitoring System Components |
|
NMS044‑LFP100‑E |
Complete NMS for use outside US including Model 831C with 831C-LOG, 831C-ELA, 831C-SW, EPS044-LFP, COM-RV50-DC-E, 2 ea. COM-ANT-HG, PRM2103-FF, EPS2116, SLP002, PSA039 & necessary cables. For use when solar insolation > 1 kW•h/m2/day |
NMS044‑LFP100‑U |
Complete NMS for use in US including Model 831C with 831C-LOG, 831C-ELA, 831C-SW, EPS044-LFP, COM-RV50-DC-U, 2 ea. COM-ANT-HG, PRM2103-FF, EPS2116, SLP002, PSA039 & necessary cables. For use when solar insolation > 1 kW•h/m2/day |
NMS044‑SLA100‑E |
Complete NMS for use outside US including Model 831C with 831C-LOG, 831C-ELA, 831C-SW, EPS044-SLA, COM-RV50-DC-E, 2 ea. COM-ANT-HG, PRM2103-FF, EPS2116, SLP002, PSA039 & necessary cables. For use when solar insolation > 1 kW•h/m2/day |
NMS044‑LFP100‑U |
Complete NMS for use in US including Model 831C with 831C-LOG, 831C-ELA, 831C-SW, EPS044-LFP, COM-RV50-DC-U, 2 ea. COM-ANT-HG, PRM2103-FF, EPS2116, SLP002, PSA039 & necessary cables. For use when solar insolation > 1 kW•h/m2/day |
Technical specifications of Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
STANDARDS |
The Model 831C meets the specifications of the following standards: |
Sound Level Meter Standards |
IEC61672-1 Ed. 2.0 (2013) Class 1, Group X |
IEC60651 Ed 1.2 (2001) plus Amendment 1 (1993-02) and Amendment 2 (2000-10) Type 1, Group X |
IEC60804 (2000-10) Type 1, Group X |
ANSI S1.4-2014 Class 1 |
ANSI S1.43-1997 Type 1 |
DIN 45657 |
Octave Filter Standards (Option 831C- OB3) |
IEC61260 Ed. 2.0 (2014) Class 1, all filters |
ANSI S1.11-2014 Class 1, all filters |
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use |
2006/95/EC Low Voltage Safety Directive |
IEC 61010-1 Ed. 3.0 (2010-06) |
EMC Immunity and Emission |
2004/08/EC EMC Directive |
IEC 61326-1 Ed. 2.0 (2012-07) |
IEC 61672-1 Ed. 2.0 (2013-09) |
FCC Title 47 CRF Part 15, Class B |
SPECIFICATIONS |
||||
General |
||||
Reference Level |
114.0 dB re. 20 µPa |
|||
Reference Level Range |
Single large range for SLM measurements |
|||
Reference Frequency |
1000 Hz |
|||
Reference Direction |
0° is perpendicular to the microphone diaphragm |
|||
Operating Temperature |
≤ ± 0.5 dB variation between -22 °F to +122 °F (-30 °C to 60 °C) |
|||
Storage Temperature |
-22 °F to 158 °F (-30 °C to 60 °C) |
|||
Humidity |
≤ ± 0.5 dB variation from 10% to 99% relative humidity (non-condensing) |
|||
Equivalent Microphone Impedance |
12 pF |
|||
Digital Display Update Rate |
Four times per second (0.25 sec between updates). First display indication is available 0.25 seconds after initiation of a measurement. |
|||
Effect of an Extension Cable |
None up to 200 ft (61 m) with EXCxxx cable |
|||
Approvals |
CE, ROHS, WEEE |
|||
Extended Weather Options |
-40 °F to +158 ºF (-40 °C to +70 ºC) operation with CER-831-E |
|||
Physical |
||||
Length with Microphone and Preamplifier |
11.35 in |
29.0 cm |
||
Length, Instrument Body Only |
8.8 in |
22.4 cm |
||
Width |
2.8 in |
7.1 cm |
||
Depth |
1.6 in |
4.1 cm |
||
Weight with Batteries, No Preamplifer or Microphone |
17.3 oz |
490 g |
||
Weight with Batteries, Preamplifer, and Microphone |
18.8 oz |
532 g |
||
Sound Level Meter Specifications |
||||
Averaging (Integration Method) |
Linear or Exponential |
|||
Time Weightings |
Slow, Fast,or Impulse |
|||
Frequency Weightings |
A, C, and Z |
|||
Peak Detector Frequency Weighting |
A, C, or Z |
|||
Gain |
0 dB or +20 dB |
|||
Sample Rate |
51,200 Hz |
|||
Peak Rise Time |
30 µs |
|||
Metrics Measured |
Leq, Lmax, Lmin, Lpeak, Ln (6 values), LDN, LDEN, LCeq – LAeq |
|||
Resolution Specifications |
||||
Levels |
0.1 dB |
|||
Elapsed Time |
0.1 s |
|||
Real Time Clock |
1 s |
|||
Calendar |
Through January 1, 2038 |
|||
Integration Time |
||||
Time Averaged Levels and Sound Exposure Levels |
||||
Minimum |
0.1 s |
|||
Maximum with Daily Autostore Enabled |
Unlimited |
|||
Maximum with Daily Autostore Disabled |
> 23 days with error < 0.5 dB |
|||
Broadband Noise Levels |
||||
Self-generated Electrical Noise |
0 dB Gain |
20 dB Gain |
||
Weighting |
Typical (dB) |
Max (dB) |
Typical (dB) |
Max (dB) |
A |
13 |
15 |
6 |
10 |
C |
15 |
22 |
12 |
16 |
Z |
22 |
25 |
19 |
26 |
Self-generated Total Noise |
0 dB Gain |
20 dB Gain |
||
Weighting |
Typical (dB) |
Max (dB) |
Typical (dB) |
Max (dB) |
A |
18 |
19 |
17 |
17 |
C |
18 |
23 |
17 |
19 |
Z |
23 |
26 |
21 |
26 |
Note: Combination of the electronic noise and the thermal noise of the 377B02 microphone at 68 °F (20 °C) measured in a sealed and vibration isolated cavity with an averaging time of 60 seconds. Electronic noise of the instrument with an ADP090 (12 pF) in place of the microphone highest anticipated self-generated noise. |
FEATURES |
|
Ln Statistics |
|
Number of Selectable Parameters |
6 in xx.xx% format |
Distribution Resolution |
0.1 dB |
Spectral Statistics |
Requires Octave Analysis option (831C-OB3) |
Markers |
|
Number of Markers |
10 |
Prenamed Markers |
Truck, Automobile, Motorcycle, Aircraft, Exclude |
Back Erase Time |
5 or 10 s |
Measurement Control Modes |
|
Available Modes |
Manual Stop, Timed Stop, Stop when Stable, Continuous, Single Block Timer, Daily Block Timer |
Timed Stop |
Time in hh:mm:ss |
Stop When Stable |
Delta level in xx.x dB and time in hh:mm:ss |
Continuous with Daily Auto-Store |
1, 2, 4, 6, 12, 24, 48, 96 or 144 files per day, automated file numbering |
Restart after Power Failure |
Automatic if powered by 12 VDC and continuous run mode |
Single Block Timer |
Start date and time to end date and time |
Daily Block Timer |
Up to 3 blocks between each start and end date |
Clock Stability |
|
< 1 sec in 24 hours, at 75 ºF (+24 ºC) |
|
< 10 sec in 30 days, at -40 °F to +158 °F (-40 °C to +70 °C) |
|
<1 s when using NTP |
|
Microphone Input |
|
Connector |
Latching 5-pin connector |
Input Impedance |
100 kΩ and 300 pF |
Full Scale Input (0 dB gain) |
14 Vpeak |
ICP Current (requires ADP074) |
4 mA |
AC/DC Output |
|
Jack |
2.5 mm (3/32 in) female |
AC Output Voltage Range |
± 14 Vpeak (preamplifier output) |
± 2.1 Vpeak with 0, 20 or 40 dB gain (for LINE inputs) |
|
AC Output Recommended Load |
10 kΩ or greater |
DC Output Voltage Scale |
10 mV per dB, 0 V for 0 dB, 1 V = 100 dB |
DC Output Frequency & Time Weighting |
Follows SLM Settings: A, C, or Z and S, F, or I |
Power |
|
Batteries |
4-AA (LR6) NiMH, 1.5 V Lithium or Alkaline cells (supplied with 2500 mAh NiMH) |
External Power (5 V from USB) |
USB Mini-B connector to * USB interface from computer * PSA029 AC to DC power adaptor |
External Power |
I/O connector: 10 to 25 VDC (Use cable CBL140) |
Operating Time (with power save options) |
> 18 hours (1.5 V Lithium batteries) |
> 8 hours (Alkaline or NiMH batteries) |
|
Power Consumption with PRM831 |
1.1 W (backlight off, running) |
≤ 2 W (with DVX012) |
|
5 W (maximum) |
|
Memory Retention |
|
Data Memory |
Non-volatile flash memory, backup performed every minute |
Real-time Clock |
≥ 1 year with batteries removed |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Portable outdoor noise monitoring system with sound recording Larson Davis SoundAdvisor™ NMS-SE-831C
There are no reviews yet.