Karl Fischer titrators INESA REX ZDY-504
Price: Contact
| Model | ZDY-504 |
| Manufacturer | INESA/ REX |
| Power supply | AC (220±22) V, (50±1) Hz |
| Weight | 10 Kg |
| Size | 340 x 400 x 400 mm |
| Condition | Stocking |
| Warranty | 12 months |
Karl Fischer titrators INESA REX ZDY-504 includes volumetric KF titration and Coulometric KF titration.
I. Specification Karl Fischer INESA REX ZDY-504 titration system
Features of INESA REX ZDY-504:
- Karl Fischer titrators INESA REX ZDY-504 with LCD display.
- Titration methods, curves and results are displayed in detail.
- Volumetric KF Titration and Coulometric KF Titration supported.
- Data analysis feature helps users review and compare results.
- Data can be easily transferred to the printer via the RS-232 communication interface.
- The automatic reset feature restores all settings back to factory defaults.
- Karl Fischer INESA REX ZDY-504 meets ISO 9001.
INESA REX ZDY-504 - Volumetric Karl Fischer titration:
- Support KF Titration Mode and Titrator Detection Mode.
- Auto-fill, auto-bleach and auto-reagent mixing features ensure safe handling of Karl Fischer chemicals.
- Automatic/manual background drift correction ensures accurate results.
- Selectable units include mg, mg/L, %, ppm, and more.
- Configurable parameters, including unit of measure, bias current, stirring speed, titration rate, stopping volume, endpoint potential, stopping criterion and more.
- Store up to 200 titration data sets (GLP compliant).
INESA REX ZDY-504 - Karl Fischer coulometric titration:
- Generator box with diaphragm.
- Automatic/manual background drift correction ensures accurate results.
- Selectable units include μg 、 mg 、% 、 ppm 、 mg/L 、 μg/mL, etc..
- Configurable parameters, including unit of measurement, bias current, stirring speed, generator current, endpoint potential, stopping criterion and more.
- Store up to 200 titration data sets (GLP compliant).
***You may be interested in GMGA's cell harvesting system - Esco Vietnam: https://gmga.vn/en/danh-muc/process-equipment/cell-harvesting-system/
II. Specifications Karl Fischer titrators INESA REX ZDY-504
|
Model |
ZDY-504 | |
| Volumetric Titration | Range |
(0.1mg~250)mg, |
|
Polarization Current Accuracy |
1μA±0.2μA; 50μA±10μA; | |
| Repeatability |
±0.5% |
|
|
Coulometric Titration |
Range | 10μg~20mg |
| Polarization Current Accuracy |
1μA±0.2μA; 50μA±10μA; |
|
|
Working Current |
1, 1.86, 5, 10μg (H2O)/S | |
| Accuracy |
± (5%+3) μg |
|
|
Repeatability |
RSD of 100μg sample measurement result ≤3% | |
| General | Power supply |
AC (220±22) V, (50±1) Hz |
|
Dimension (mm)& Weight (kg) |
340*400*400; 10 | |
| Package Size |
540*490*480mm; 13kg |
|
***Product main path: INESA REX ZDY-504 Premium Performance smart Karl Fischer Titrator.
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide


Review Karl Fischer titrators INESA REX ZDY-504
There are no reviews yet.