Interface CAN/CAN FD to USB robust single-channel Kvaser U100-X3 with reinforced galvanic isolation and 16-pin OBDII plug

Price: Contact

Model EAN: 73-30130-01268-4
Manufacturer Kvaser
Power supply Interface USB 2.0
Weight 185 g
Size 38 x 128 x 26 mm
Condition Stocking
Warranty 24 months

The Kvaser U100-X3 (EAN: 73-30130-01268-4) is a robust, galvanically-reinforced single-channel CAN/CAN FD to USB interface with a 16-pin OBDII plug.

With an intelligent LED that displays bus loads and error frames, an industry-leading IP67 rating and an innovative connector system, the U100 has numerous stand-out features. Fully compatible with J1939, CANopen, NMEA 2000® and DeviceNet, this suits rugged and higher voltage applications in marine, industrial, construction, heavy-duty, agriculture and automotive, including electric vehicle markets.

The Kvaser U100 is also available with 9-pin D-SUB, J1939-13 Type II or M12 CAN connectors.

I. Major features of Interface CAN/CAN FD to USB Kvaser U100-X3

  • USB CAN interface.
  • Powered through the USB connector.
  • Supports CAN FD, up to 8 Mbit/s (with correct physical layer implementation).
  • Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
  • Lightweight robust housing made of glass fibre reinforced polyamide overmolded with TPE.
  • Intuitive LED UI.
  • Reinforced galvanic isolation, design validated with 5000 VAC rms applied for 60 s.
  • Industrial grade temperature range, −40 ◦C to +85 ◦C.
  • 20 000 msg/s, each timestamped with a resolution of 100 μs.
  • Fully compatible with applications written for other Kvaser CAN hardware with Kvaser CANlib.
  • Support for SocketCAN.
  • Fully compatible with J1939, CANopen, NMEA 2000⃝R and DeviceNet.
  • IP67 rated housing.

II. Software

  • Documentation, Kvaser CANlib SDK and drivers can be downloaded for free at: www.kvaser.com/downloads.
  • Kvaser CANlib SDK is a free resource that includes everything you need to develop soſtware for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Visual Basic, Python and t programming language.
  • Kvaser CAN hardware is built around the same common soſtware API. Applications developed using one device type will run without modification on other device types.

III. Hardware of Interface CAN/CAN FD to USB robust single-channel

Hardware installation:

  • The Kvaser U100-X3 may be inserted in any free USB socket on the host computer. You do not need to switch the power off before inserting or removing the device. For the Kvaser U100-X3 to communicate with the host computer, a compatible version of the Kvaser driver and firmware must be installed.
  • The driver is installed by running the file kvaser_drivers_setup.exe. For instructions on how to update the firmware. The latest version of the driver and firmware can be downloaded from: www.kvaser.com/download.
  • The firmware is downloaded and installed directly on the Kvaser U100-X3 and the driver is installed on the host computer. After the driver has been installed on the host computer, the firmware may then be downloaded and installed on the Kvaser U100-X3.

USB connection:

  • The USB connector for the Kvaser U100-X3 is a standard USB type “A” connector.
  • Connect the device to your computer using any high quality USB 2.0 certified cable. The maximum total USB cable length is 5 m (∼ 16 ft).

CAN connection:

  • The Kvaser U100-X3 has one CAN channel.
  • The CAN connector for the Kvaser U100-X3 is the 16-pin OBDII Type B plug.

Interface-can-can-fd-to-usb-robust-single-channel-kvaser-u100-x3-with-reinforced-galvanic-isolation-and-16-pin-obdii-plug-ean-73-30130-01268-4

CAN bus termination:

  • Every CAN bus must be terminated with a 120 Ohm resistor at each end of the bus. The Kvaser U100-X3 does not contain any CAN bus termination, because their inclusion could cause severe disturbance in a system which is already correctly terminated.
  • For laboratory or testing use, the exact value of the termination resistors is not always critical. Sometimes a single terminator is sufficient. For production, proper termination is essential. If you see error frames on the bus, you should check the termination.

Power supply:

  • The Kvaser U100-X3 is powered through the USB connector. Make sure the USB power source can supply enough current (500 mA). If using a USB hub, choose an externally powered one to be safe.

LED Indicators:

  • A Kvaser U100-X3 device has two traffic LED bars where part of each LED bar is also used as a status area. The TX LED Bar has a status area towards the USB end of the bar, and the RX LED bar has a status area towards the CAN end of the bar.

Technical data of Interface CAN/CAN FD to USB robust single-channel Kvaser U100-X3

CAN Channels

1

CAN Connector

16-pin OBDII Type B plug

CAN Transceivers

ADM3055E (Compliant with ISO 11898-2)

CAN Controller

Built into the processor.

Galvanic isolation

Yes, reinforced. Design validated with 5000 VAC rms applied for 60 s.

CAN Bit Rate

10 kbit/s to 1 Mbit/s

CAN FD Bit Rate

Up to 8 Mbit/s (with correct physical layer implementation).

Time stamp resolution

100 μs

Max message rate

20 000 msg/s per channel

Error Frame Detection

Yes

Error Frame Generation

No

Silent mode

No

Kvaser MagiSync

No

Kvaser t programming

No

Kvaser CANtegrity

No

Host interface

USB 2.0, standard USB type “A” connector

Host OS

Windows (7 or later), Linux

Power consumption

Typical 250 mA

Dimensions

38 x 128 x 26 mm for body

Cable length

USB 1.0 m, CAN 0.3 m

Weight

185 g including connectors

Operating temperature

−40 ◦C to +85 ◦C

Storage temperature

−40 ◦C to +85 ◦C

Relative humidity

0 % to 85 % (non-condensing)

IP Rating Housing

IP67

IP Rating CAN connector

IP40 Mated

IP Rating USB connector

IP40 Mated

Review Interface CAN/CAN FD to USB robust single-channel Kvaser U100-X3 with reinforced galvanic isolation and 16-pin OBDII plug

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Interface CAN/CAN FD to USB robust single-channel Kvaser U100-X3 with reinforced galvanic isolation and 16-pin OBDII plug
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.