Precision sound level calibrator Larson Davis CAL200

Price: Contact

Model CAL200
Manufacturer LARSON DAVIS (a part of the PCB PIEZOTRONICS)
Power supply 9 V NEDA 1604 A or IEC 6LR61
Weight 156 g
Size 106.1 x 63.4 x 25.9 mm
Condition Stocking
Warranty 12 months

Precision sound level calibrator Larson Davis CAL200 has been designed for both field and laboratory use and the accuracy has been calibrated to a reference traceable to the National Institute of Standards and Technology (NIST).

I. Specifications of Sound calibrator Larson Davis CAL200

1/2" MICROPHONES - IEC 60942 CLASS 1 CALIBRATOR

Precision sound level calibrator Larson Davis CAL200 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment with 1/2" microphones. It can provide an output level of either 94.0 or 114.0 dB (switch-selectable) at a frequency of 1 kHz. Adaptors for 1⁄8", ¼", and 3⁄8" microphones are available as optional accessories.

The Larson Davis CAL200 features a stable sound pressure independent of the battery condition. In addition, the Larson Davis CAL200 will turn off automatically to preserve battery and guarantee a stable output.

In addition to precision acoustic calibrators, factory calibration services for Larson Davis products are available through the CAL+ program. CAL+ service is provided with all Larson Davis calibrations and includes a complete multi-point factory test, free firmware upgrade to the latest version where applicable, labor warranty extended for one year[1], worn consumables replaced at no charge[2], and more. Contact us for details.

Precision-sound-level-calibrator-larson-davis-cal200

HIGHLIGHTS

  • Output level: 94 or 114 dB
  • Output frequency: 1 kHz
  • 1/2" microphone opening
  • IEC 60942-1:2003 compliant
  • Internal battery
  • Output level independent of battery condition
  • Adaptors: ¹⁄8", 1/4", 3⁄8" microphones.

TYPICAL APPLICATIONS

Field or laboratory calibration of:

  • Sound level meters
  • Noise dosimeters
  • Noise monitoring stations.

TYPE APPROVAL/ SAMPLE APPROVALS

Technical specifications of Precision sound level calibrator Larson Davis CAL200

SPECIFICATIONS

Acoustic

Calibration Sound Pressure
Level

114.0 dB and 94.0 dB ± 0.3 dB SPL re: 20 μPa (114.0 dB is the principal sound pressure level)

Equivalent Free-field Level

-0.12 dB for 1/2″ microphones

Frequency

1 kHz ± 0.7%

Harmonic Distortion

< 2 %

Stability After Pressing On

± 0.1 dB after 2 seconds

Minimum Stabilizing Time

10 seconds after coupling microphone and calibrator

Reference Conditions

101.3 kPa, 23 ºC and 50 % RH

Environmental

Static Pressure Range

65 kPa to 108 kPa

SPL variation < ± 0.25 dB

Temperature Range

-10 ºC to +50 ºC

SPL variation < ± 0.4 dB
Frequency variation < ± 7 Hz

Humidity Range

10 % to 90 % RH non-condensing

SPL variation < ± 0.3 dB
Frequency variation < ± 7 Hz

Storage Temperature

-40 ºC to +60 ºC

Storage Humidity

0 % to 90 % RH (non-condensing)

Physical

Effective Volume of Calibrator and Microphone

> 6.1 in3 (100 cm3)

Dimensions (L x W x H)

4.18 x 2.5 x 1.02 in (106.1 x 63.4 x 25.9 mm)

Weight

5.5 oz (156 g)

Power Supply

Battery

9 V NEDA 1604 A or IEC 6LR61

Battery Voltage Operating Range

6.7 V to 10 V

Traceability

Traceability

Traceable to National Institute of Standards and Technology (NIST)

Supplied Accessories

9 V Alkaline Battery

Users Manual

Related Products

ADP109

Adaptor for 1/4″ microphones

ADP031

Adaptor for 3⁄8″ microphones

ADP075

Adaptor for 1⁄8″ microphones

Related Products

CAL250

Class 1 Precision Acoustic Calibrator (250 Hz)

CAL150

Class 2 Precision Acoustic Calibrator (1000 Hz)

COMPLIANCE

Acoustic

ANSI S1.40-2006, Class 1

IEC 60942-2003, Class 1

IEC 60942:2017, Class 1

IEC 60942:2018, Class 1

Safety

IEC 61010-1:2001

EMC

EU directive 2004/108/EC

IEC 61326-1:2005

For Use with Microphones of Type

IEC 61094-4:1995

1/2″ WS2P, WS2F and WS2D microphones; no adaptor required

1/4″ WS3P, WS3F and WS3D microphones with ADP109 adaptor

According to IEC 61094-1:2000

1/2″ LS2P

Other Microphones

3⁄8″ with ADP020 adaptor

For Use with Sound Level Meters and Noise Dosimeters

ANSI S1.4 Type 1

ANSI S1.25

IEC 61672 Class 1

IEC 61252

[1] Requires regular annual factory calibration. Limited to seven (7) years.

Review Precision sound level calibrator Larson Davis CAL200

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Precision sound level calibrator Larson Davis CAL200
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide

      OTHER SAME PRODUCTS

      PCR thermal circulator Esco Aeris™ AERIS-MB series

      Model: AERIS-BG096/ B4830/ BG384/ BD048 / B4076

      Industrial endoscope camera JK series 7 ” 360 °

      Model: JKVS / JKS / JKVS(R) / JKR / JKS(R)