| Model | CAL200 |
| Manufacturer | LARSON DAVIS (a part of the PCB PIEZOTRONICS) |
| Power supply | 9 V NEDA 1604 A or IEC 6LR61 |
| Weight | 156 g |
| Size | 106.1 x 63.4 x 25.9 mm |
| Condition | Stocking |
| Warranty | 12 months |
Precision sound level calibrator Larson Davis CAL200 has been designed for both field and laboratory use and the accuracy has been calibrated to a reference traceable to the National Institute of Standards and Technology (NIST).
I. Specifications of Sound calibrator Larson Davis CAL200
1/2" MICROPHONES - IEC 60942 CLASS 1 CALIBRATOR
Precision sound level calibrator Larson Davis CAL200 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment with 1/2" microphones. It can provide an output level of either 94.0 or 114.0 dB (switch-selectable) at a frequency of 1 kHz. Adaptors for 1⁄8", ¼", and 3⁄8" microphones are available as optional accessories.
The Larson Davis CAL200 features a stable sound pressure independent of the battery condition. In addition, the Larson Davis CAL200 will turn off automatically to preserve battery and guarantee a stable output.
In addition to precision acoustic calibrators, factory calibration services for Larson Davis products are available through the CAL+ program. CAL+ service is provided with all Larson Davis calibrations and includes a complete multi-point factory test, free firmware upgrade to the latest version where applicable, labor warranty extended for one year[1], worn consumables replaced at no charge[2], and more. Contact us for details.

HIGHLIGHTS
- Output level: 94 or 114 dB
- Output frequency: 1 kHz
- 1/2" microphone opening
- IEC 60942-1:2003 compliant
- Internal battery
- Output level independent of battery condition
- Adaptors: ¹⁄8", 1/4", 3⁄8" microphones.
TYPICAL APPLICATIONS
Field or laboratory calibration of:
- Sound level meters
- Noise dosimeters
- Noise monitoring stations.
TYPE APPROVAL/ SAMPLE APPROVALS
Technical specifications of Precision sound level calibrator Larson Davis CAL200
SPECIFICATIONS |
||
|
Acoustic |
||
|
Calibration Sound Pressure |
114.0 dB and 94.0 dB ± 0.3 dB SPL re: 20 μPa (114.0 dB is the principal sound pressure level) |
|
|
Equivalent Free-field Level |
-0.12 dB for 1/2″ microphones |
|
|
Frequency |
1 kHz ± 0.7% |
|
|
Harmonic Distortion |
< 2 % |
|
|
Stability After Pressing On |
± 0.1 dB after 2 seconds |
|
|
Minimum Stabilizing Time |
10 seconds after coupling microphone and calibrator |
|
|
Reference Conditions |
101.3 kPa, 23 ºC and 50 % RH |
|
|
Environmental |
||
|
Static Pressure Range |
65 kPa to 108 kPa |
SPL variation < ± 0.25 dB |
|
Temperature Range |
-10 ºC to +50 ºC |
SPL variation < ± 0.4 dB |
|
Humidity Range |
10 % to 90 % RH non-condensing |
SPL variation < ± 0.3 dB |
|
Storage Temperature |
-40 ºC to +60 ºC |
|
|
Storage Humidity |
0 % to 90 % RH (non-condensing) |
|
|
Physical |
||
|
Effective Volume of Calibrator and Microphone |
> 6.1 in3 (100 cm3) |
|
|
Dimensions (L x W x H) |
4.18 x 2.5 x 1.02 in (106.1 x 63.4 x 25.9 mm) |
|
|
Weight |
5.5 oz (156 g) |
|
|
Power Supply |
||
|
Battery |
9 V NEDA 1604 A or IEC 6LR61 |
|
|
Battery Voltage Operating Range |
6.7 V to 10 V |
|
|
Traceability |
||
|
Traceability |
Traceable to National Institute of Standards and Technology (NIST) |
|
|
Supplied Accessories |
||
|
9 V Alkaline Battery |
||
|
Users Manual |
||
|
Related Products |
||
|
ADP109 |
Adaptor for 1/4″ microphones |
|
|
ADP031 |
Adaptor for 3⁄8″ microphones |
|
|
ADP075 |
Adaptor for 1⁄8″ microphones |
|
|
Related Products |
||
|
CAL250 |
Class 1 Precision Acoustic Calibrator (250 Hz) |
|
|
CAL150 |
Class 2 Precision Acoustic Calibrator (1000 Hz) |
|
COMPLIANCE |
||
|
Acoustic |
||
|
ANSI S1.40-2006, Class 1 |
||
|
IEC 60942-2003, Class 1 |
||
|
IEC 60942:2017, Class 1 |
||
|
IEC 60942:2018, Class 1 |
||
|
Safety |
||
|
IEC 61010-1:2001 |
||
|
EMC |
||
|
EU directive 2004/108/EC |
||
|
IEC 61326-1:2005 |
||
|
For Use with Microphones of Type |
||
|
IEC 61094-4:1995 |
1/2″ WS2P, WS2F and WS2D microphones; no adaptor required |
|
|
1/4″ WS3P, WS3F and WS3D microphones with ADP109 adaptor |
||
|
According to IEC 61094-1:2000 |
1/2″ LS2P |
|
|
Other Microphones |
3⁄8″ with ADP020 adaptor |
|
|
For Use with Sound Level Meters and Noise Dosimeters |
||
|
ANSI S1.4 Type 1 |
||
|
ANSI S1.25 |
||
|
IEC 61672 Class 1 |
||
|
IEC 61252 |
||
|
[1] Requires regular annual factory calibration. Limited to seven (7) years. |
||
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide


Review Precision sound level calibrator Larson Davis CAL200
There are no reviews yet.