| Model | EAN: 73-30130-00832-8 |
| Manufacturer | Kvaser |
| Power supply | USB interface |
| Weight | 50 g |
| Size | 57 x 120 x 13 mm |
| Condition | Stocking |
| Warranty | 24 months |
Bare circuit board five channel bus interface USB-to-CAN/CAN FD standalone data logger configurable using Kvaser’s Memorator Config Tool, Kvaser Memorator Pro 5xHS CB (EAN: 73-30130-00832-8) is capable of running user- developed scripts, written in the Kvaser t programming language. Guidance in creating t programs is supplied. The device is also supported in CANlib, Kvaser’s universal soſtware development kit.
I. Major features of Bare circuit board five channel bus interface USB-to-CAN/CAN FD standalone data logger
- Monitor 5 CAN channels simultaneously using just one device.
- Automatically time synchronises the data transmitted and received across all five channels.
- Built-in Kvaser MagiSyncTM technology time synchronises with other Kvaser interfaces connected to the same PC, resulting in simpler and more accurate multichannel data capture.
- Script functionality allows users to develop customised t-script applications written in the Kvaser t programming language.
- "Plug and play" installation.
- Log data to an expandable SD card slot.
- Power derived from the USB connection, CAN bus, or an in-built power supply.
- Compatible with J1939, CANopen, NMEA 2000® and DeviceNet.
- Supports CAN FD.
- NOTE: This product ships with a 16GB Industrial Grade SDHC cards (-40 to +85°C) included
II. Filters
- Log continuously, or logging can be triggered by creating advanced triggers based on messages, data signal values, error messages, external trigger's falling or rising edge, and I/O signals.
- Pre- and post-triggers are available without buffer size restrictions, limited by disk space only.
- Filter out selectable messages and/or signals to be logged. The identifiers can be picked from a database, or all messages can be logged.
- Support for pass as well as stop filters.
- Create a counting pass filter to have a message logged at enumerated occurrence.
- Handles up to 20,000 msgs/s in standalone logger mode.
- External digital output that can drive an LED or a buzzer.
- Supports Silent Mode - Log bus traffic safely without interfering and "listen-only" mode for bus analysis tools
III. Memory cards and functions
- Supports SD and SDHC memory card formats.
- Set up several devices in a daisy chain for larger logging capacity.
IV. Configuration Software in the PC
- Easy to use graphic configuration tool - Memorator Tools.
- Configuration of the CAN controller, i.e. bit rate and filters.
- Configuration of the trigger conditions.
- Configuration of filter for messages to be stored.
- Configuration upload and download via USB.
- Using the included Kvaser Dispatcher software, a complete measurement setup can be turned into a self-installing package that is sent to a remote location to carry out a specific logging task.
V. Soſtware for Bare circuit board five channel bus interface Kvaser Memorator Pro 5xHS CB
- Documentation, Kvaser CANlib SDK and drivers can be downloaded for free at: www.kvaser.com/ downloads.
- Kvaser CANlib SDK is a free resource that includes everything you need to develop soſtware for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Visual Basic, Python and t programming language.
- Kvaser CAN hardware is built around the same common soſtware API. Applications developed using one device type will run without modification on other device types.
VI. Connectors
USB connector:
- The Kvaser Memorator Pro 5xHS CB has a standard USB type “Micro-B” female connector.

CAN connector:
- CAN is connected using a 12-way (top side) and a 10-way connector (bottom side) and mate with Molex 51021 PicoBladeTM (housing 51021-1200 and 51021-1000, with terminal 50079-8000).

|
Pin configuration of the top-side CAN connector |
|
| Pin Number |
Function |
|
1 |
CAN_L channel 2 |
| 2 |
CAN_H channel 2 |
|
3 |
GND channel 2 |
| 4 |
External trigger output |
|
5 |
Not connected |
| 6 |
Not connected |
|
7 |
External trigger input |
| 8 |
CAN_L channel 1 |
|
9 |
CAN_H channel 1 |
| 10 |
GND channel 1 |
|
11 |
Power supply to the device |
| 12 |
Shield |
|
Pin configuration of the bottom-side CAN connector |
|
| Pin Number |
Function |
|
1 |
GND channel 3 |
| 2 |
CAN_L channel 3 |
|
3 |
CAN_H channel 3 |
| 4 |
GND channel 4 |
|
5 |
CAN_L channel 4 |
| 6 |
CAN_H channel 4 |
|
7 |
GND channel 5 |
| 8 |
CAN_L channel 5 |
|
9 |
CAN_H channel 5 |
| 10 |
Not connected |
Technical data of Bare circuit board five channel bus interface USB-to-CAN/CAN FD standalone data logger Kvaser Memorator Pro 5xHS CB
|
Bit Rate |
40 – 1000 kbps |
| CAN Channels |
5 |
|
CAN FD |
Yes |
| Certifications |
CE, RoHS |
|
Connector |
Molex 51021 PicoBladeTM |
| Current Consumption |
Up to 3W |
|
Dimensions |
57 x 120 x 13 mm |
| Error Frame Detection |
Yes |
|
Galvanic Isolation |
Yes |
| Operating Temperature Range |
-40 °C to +85 °C |
|
PC Interface |
USB |
| Silent Mode |
Yes |
|
Timestamp Resolution |
1 μs |
| t-Script Support |
Yes |
|
Weight |
50g |
| Operating Systems |
Windows, Linux |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide
OTHER SAME PRODUCTS
Bare circuit board of Leaf Light v2 interface Kvaser Leaf Light HS v2 CB interface
Model: EAN: 73-30130-00733-8
Circuit board USB-to-CAN bus interface single-channel high speed Kvaser Leaf v3 CB
Model: EAN: 73-30130-01532-6


Review Bare circuit board five channel bus interface USB-to-CAN/CAN FD standalone data logger Kvaser Memorator Pro 5xHS CB
There are no reviews yet.