Cell harvesting system Esco TideXcell ® (TXLHS)

Price:

Model
Manufacturer
Power supply
Weight
Size
Condition
Warranty
Cell harvesting system Esco TideXcell ® (TXLHS) Gentle Giant's harvesting partner

I. Specification of the Esco TideXcell ® Automatic Cell Harvester (TXLHS)

Tide motion in cell harvesting system Esco TideXcell ® (TXLHS):

[video width="1280" height="720" mp4="https://gmga.vn/wp-content/uploads/2021/11/Máy-thu-hoạch-tế-bào-tự-dộng-Esco-TideXcell-®-TXLHS_01.mp4" autoplay="true"][/video]

Features of Esco TideXcell ® (TXLHS):

  • TThe entire harvesting process can be set up from washing to harvesting cells in a self-contained, automatic cell harvester.
  • Suitable for cell harvesting from 2L TideXcell ® matrix flasks to 20L matrix flasks
  • Cell seed source support for TideXcell™-010 up to TideXcell™-100 systems.
  • Harvest live cells within 1 to 3 hours (harvest time depends on harvest cycle).
  • Up to 10 11 tiles can be recovered with over 95% survivability from a single TXLHS unit.
  • Four (4) built-in peristaltic pumps (with option to add up to 3 more) with assignable functions.
Please note: Cell harvesting efficiency depends on the cell line used with the adherent cell harvester. Cell harvesting system Esco TideXcell ® (TXLHS)

II. Esco TideXcell ® (TXLHS) - Working principle

The TideXcell™ harvesting system uses a similar and conventional cell harvesting concept by digesting enzymatic treatment and separating the cells from the attached substrate. Procedures include: Cell harvesting system Esco TideXcell ® (TXLHS)

Setting:

  • Mount and secure the TideXcell™ Matrix flask in the TideXcell™ Harvest System and connect the TideXcell™ matrix flask to the tubular manifolds. It will act as a conduit for the introduction of phosphate-buffered saline (PBS), enzymes (usually Tryple Select, Accumax and Collagenase among others), enzyme inhibitors (when using culture media that does not contain serum), culture medium and waste container.
  • These six tubes connect to the Matrix Vessel via a manifold.

Wash:

  • Wash the substrate with phosphate-buffered saline or an equivalent solution to remove serum that may inhibit enzyme activity in the following step.

Enzyme treatment:

  • Immerse the substrate with a chosen enzyme to digest the cells until the cells round up to separate.

Cell separation:

  • Shake the matrix jar together with the matrix to remove cells from the porous matrix.

Collect:

  • Collect cells by rinsing the substrate with cell culture medium or an equivalent solution and collect cells into the harvesting tank.

III. Advantages of cell harvesting system Esco TideXcell ® (TXLHS)

  • Suitable for cell harvesting from TideXcell™ 2L Matrix Vessels to 20L Matrix Vessels.
  • Cell seed source support for TideXcell™-010 up to TideXcell™-100 systems.
  • Harvest live animal cells within 1 to 3 hours (harvest time depends on harvest cycle).
  • The entire harvesting process is done automatically in a closed system. Manual operation is also available.
  • Can recover up to 1011 tiles with over 90% survivability from a THS . unit.
Cell harvesting system Esco TideXcell ® (TXLHS)

IV. Application of the Esco TideXcell ® cell harvester

  • TideXcell ® Automated Cell Harvester (TXLHS) for adherent cell culture including but not limited to: Insect Cells, Mammal Cells, Stem Cells
  • Extending biomass for seed training from 2D to 3D
  • Autologous and allogeneic cell therapy
  • Intracellular virus.
Esco TideXcell ® (TXLHS) ***You may be interested in GMGA fermentation and bioreactors - Esco Vietnam: https://gmga.vn/en/danh-muc/process-equipment/bioreactors-and-fermenters/

V. Specifications cell harvesting system Esco TideXcell ® (TXLHS)

Infrastructure

Exterior dimesion (WxDxH) Controller unit: 80cm x 91cm x 181.2cm Main chamber: 110cm x 110cm x 188.7cm
Weight

1,330 kg not including 2/20L adaptor (18kg)

Power

Single phase, AC, 220 V, 50/50 Hz
Gas Input

At least 0.5 MPa from the air source

Other

RS485 communication port
Function: Rotation Functional unit

Rotary motor

Work

750 W
Range

0°~180° (back and forth)

Rate

0~10 rpm ± 2 rpm
Period

0~999 sec ± 5 sec

Function: Shake

Functional unit Shake motor
Work

3.5 kW at 300 rpm

Range

13cmmax
Rate

50~300 rpm ± 10 rpm

Period

0~999 sec ± 5 sec(16.6 mins)
Function: Break Functional unit

Damper

Function: Feed and Harvest

Functional unit 6 Peristaltic pumps (Harvest Out, Buffer Saline In, Enzyme In, Inhibition In, Culture Medium In, Waste Recovery)
Rate

20 - 250 rpm ± 5 rpm

Period

0~999 sec ± 5 sec
Tubing

ID 9.6 mm(3/8")*WT 32 mm(1/8")

Consumable: Matrix vessel

Volume 2 L and 20 L
Material

PP

Consumable: Tubing set

Type ID:3/8", OD:5/8"
Tool: Torque wrench Range

10~45 N•m

Control: Touch panel

Size 10.4" color
Modes

Automated and manual

Efficiency

Cell recovery rate 2L Vessel: >90% recovery rate

20L Vessel: 70%~90% recovery rate

VI. Video

***Detailed product specification sheet: TideXcell® Harvesting System.

Review Cell harvesting system Esco TideXcell ® (TXLHS)

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Cell harvesting system Esco TideXcell ® (TXLHS)
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide