Handheld sound level calibrator Larson Davis CAL150
Price: Contact
Model | CAL150 |
Manufacturer | LARSON DAVIS (a part of the PCB PIEZOTRONICS) |
Power supply | 9 V NEDA 1604 A or IEC 6LR61 |
Weight | 156 g |
Size | 106.1 x 63.4 x 25.9 mm |
Condition | Stocking |
Warranty | 12 months |
Handheld sound level calibrator Larson Davis CAL150 has been designed for both field and laboratory use and the accuracy has been calibrated to a reference traceable to the National Institute of Standards and Technology (NIST).
I. Specifications of Handheld sound calibrator Larson Davis CAL150
IEC 60942 CLASS 2 CALIBRATOR
Handheld sound level calibrator Larson Davis CAL150 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
It can provide an output level of either 94.0 or 114.0 dB (switch-selectable) at a frequency of 1 kHz. CAL150 includes an adaptor for 3⁄8" microphones. A 1/4" adaptor is also available as an optional accessory.
The Larson Davis CAL150 features a stable sound pressure independent of the battery condition. In addition, the Larson Davis CAL150 will turn off automatically to preserve battery and guarantee a stable output.
In addition to precision acoustic calibrators, factory calibration services for Larson Davis products are available through the CAL+ program. CAL+ service is provided with all Larson Davis calibrations and includes a complete multi-point factory test, free firmware upgrade to the latest version where applicable, labor warranty extended for one year[1], worn consumables replaced at no charge[2], and more. Please Contact us for details.
HIGHLIGHTS
- Output level: 94 or 114 dB
- Output frequency: 1 kHz
- 1/2" microphone opening
- IEC 60942-1:2003 compliant
- Internal battery
- Output level independent of battery condition
- Adaptors: 1/4", 3⁄8" microphones.
TYPICAL APPLICATIONS
Field or laboratory calibration of:
- Sound level meters
- Noise dosimeters
- Noise monitoring stations.
Technical specifications of Handheld sound level calibrator Larson Davis CAL150
SPECIFICATIONS |
||
Acoustic |
||
Calibration Sound Pressure |
114.0 dB and 94.0 dB ± 0.3 dB SPL re: 20 μPa (114.0 dB is the principal sound pressure level) |
|
Equivalent Free-field Level |
-0.12 dB for 1/2″ microphones |
|
Frequency |
1 kHz ± 1% |
|
Harmonic Distortion |
< 2 % |
|
Stability After Pressing On |
± 0.1 dB after 2 seconds |
|
Minimum Stabilizing Time |
10 seconds after coupling microphone and calibrator |
|
Reference Conditions |
101.3 kPa, 23 ºC and 50 % RH |
|
Environmental |
||
Static Pressure Range |
65 kPa to 108 kPa |
SPL variation < ± 0.4 dB |
Temperature Range |
-10 ºC to +50 ºC |
SPL variation < ± 0.6 dB |
Humidity Range |
10 % to 90 % RH non-condensing |
SPL variation < ± 0.5 dB |
Storage Temperature |
-40 ºC to +60 ºC |
|
Storage Humidity |
0 % to 90 % RH (non-condensing) |
|
Physical |
||
Effective Volume of Calibrator and Microphone (WS2P) |
0.253 in³ (4.15 cm3) |
|
Dimensions (L x W x H) |
4.18 x 2.5 x 1.02 in (106.1 x 63.4 x 25.9 mm) |
|
Weight |
5.5 oz (156 g) |
|
Power Supply |
||
Battery |
9 V NEDA 1604 A or IEC 6LR61 |
|
Battery Voltage Operating Range |
6.7 V to 10 V |
|
Traceability |
||
Traceability |
Traceable to National Institute of Standards and Technology (NIST) |
|
Supplied Accessories |
||
9 V Alkaline Battery |
||
Adaptor ADP031 for 3/8″ microphones |
||
Users Manual |
||
Related Products |
||
CAL250 |
Class 1 Precision Acoustic Calibrator (250 Hz) |
|
CAL200 |
Class 1 Precision Acoustic Calibrator (1000 Hz) |
|
ADP109 |
Adaptor for 1/4″ microphones |
|
COMPLIANCE |
||
Acoustic |
||
ANSI S1.40-2006, Class 2 |
||
IEC 60942-2003, Class 2 |
||
IEC 60942:2017, Class 2 |
||
Safety |
||
IEC 61010-1:2001 |
||
EMC |
||
EU directive 2004/108/EC |
||
IEC 61326-1:2005 |
||
For Use with Microphones of Type |
||
IEC 61094-4:1995 |
1/2″ WS2P, WS2F and WS2D microphones; no adaptor required |
|
1/4″ WS3P, WS3F and WS3D microphones with ADP109 adaptor |
||
According to IEC 61094-1:2000 |
1/2″ LS2P |
|
Other Microphones |
3⁄8″ with ADP020 adaptor |
|
For Use with Sound Level Meters and Noise Dosimeters |
||
ANSI S1.4 Type 2 |
||
ANSI S1.25 |
||
IEC 61672 Class 2 |
||
IEC 61252 |
||
[1] Requires regular annual factory calibration. Limited to seven (7) years. |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Handheld sound level calibrator Larson Davis CAL150
There are no reviews yet.