I. Specification of CDG 7000 HF high frequency anti-interference tester
- Immunity test generator, Induction RF CDG 7000 HF 10kHz – 400MHz is a new test generator for all immunity standards to disturbances caused by high frequency fields - including BCI tests (ISO 11452-4).
- One of the very few IEC 61000-4-6 combo test systems that contains an RF signal generator, RF power amplifier, 3-channel RF voltmeter and directional coupler at a very affordable price.
- The CDG 7000 HF Inductive RF, Immunity Test Transmitter generates interference according to IEC/EN 61000-4-6 - immune to conductive interference caused by high frequency fields. The standard describes a test setup in which these high frequency disturbances can be affected on a test item without the need for complex setups with antennas, field equipment and shielded rooms. The use of coupling networks and coupling clamps generates sine waves directly in the power and signal lines. The device under test remains in its original position in the device structure, so that the overall functionality of the system can be tested..
II. Advantages of Immunity test generator, Induction RF CDG 7000 HF 10kHz – 400MHz
- This compact high frequency anti-interference tester consists of an RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a direction coupler.
- Frequency range (signal generator) 4 kHz - 1200 MHz
- RF power amplifiers are available in three different versions
- The supplied application software (HELIA 7 - Basic) enables extensive reporting functions and EUT monitoring, (HELIA 7 - BCI required for BCI tests)
- Easily expandable with external amplifier via 2nd transmitter output
- The SCPI command set allows for easy integration into your own software systems
- Interfaces: USB , LAN , GPIB (optional)
- Temperature measurement input, e.g. for BCI . stapling temperature monitoring and display
- External pulse modulation input
- Configuration, user connection 8 digital channels.

III. Models of CDG 7000 HF
- CDG 7000-25: Wired RF transmitter, according to IEC 61000-4-6100 kHz - 250 MHz, amplifier 25W Maximum test level: 10 V (15 V) with 80% AM (6 dB without) Directional coupler integration direction, with HELIA 7 software - basic USB, LAN.
- CDG 7000-75: Wired RF transmitter, according to IEC 61000-4-6100 kHz - 400 MHz, amplifier 75W Maximum test level: 30 V (40 V) with 80% AM (6 dB without) Directional coupler integration direction with HELIA 7 - Basic software USB, LAN.
- CDG 7000-75-10: Wired RF transmitter, according to IEC 61000-4-6 10kHz - 250MHz, amplifier 75W Maximum test level: 30 V (40 V) with 80% AM (6 dB without) Directional coupler integration with HELIA 7 software - basic USB, LAN.
IV. Specifications of Immunity test generator, Induction RF CDG 7000 HF 10kHz – 400MHz
RF power amplifier |
|||
25 W |
75 W | 75 W / 10k | |
Frequency range | 100 kHz-250 MHz | 100 kHz-400 MHz |
10 kHz-250 MHz |
Output power: |
|||
Nominal | 25 W | 75 W |
75 W |
Linear @ 1dB compression |
20 W | 50 W | 50 W |
Gain | 46 dB nominal | 51 dB nominal |
51 dB nominal |
Flatness |
± 1.5 dB max. | ± 1.5 dB max. | ± 1.5 dB max. |
Input power for nominal power | 1 mW / 0 dBm | 1 mW / 0 dBm |
1 mW / 0 dBm |
Input / output impedance |
50 Ω | 50 Ω | 50 Ω |
Input VSWR | 1.5 : 1 max. | 1.5 : 1 max. |
1.5 : 1 max. |
Harmonic distortion |
< -20 dBc @ 20 W | < -20 dBc @ 50 W | < -20 dBc @ 50 W |
Noise | typ. 5 dB | typ. 7 dB |
typ. 7 dB |
Spurious |
< -75 dBc to 10 W | < -75 dBc to 10 W |
< -75 dBc to 10 W |
RF Generator |
|
Two switchable outputs |
2 x SMA ( only one can be used at a time ) |
Frequency range |
9 kHz to 1.2 GHz ( usable ab 4 kHz) |
Frequenzauflösung |
1 Hz |
Output level range |
0 to -63 dBm |
Output level resolution |
0.1 dB |
Harmonics |
< 30 dBc |
Spurious |
< 45 dBc |
Amplitudenmodulation (intern) |
0 bis 100%, Auflösung 1% |
Amplitudenmodulation (extern) |
0 to 100% , max. Amplitude 1V = 100%, BNC Rifle |
Heart rate modulation (internal) |
5 - 95%, resolution 1% |
Pulse modulation (external) |
DC…1 MHz, 3,3/5V CMOS/TTL, BNC Buchse |
LF Generator (Modulation) |
|
Connection |
BNC Buchse |
Frequency range |
1 Hz to 100 kHz |
Frequenzauflösung |
0.1 Hz |
Signal |
Sine wave / rectangle signal / triangular |
Amplitude |
0...1 V |
RF Voltmeter (Testlevel) |
|
Connection |
BNC Buchse |
Frequency range |
9 kHz to 1.2 GHz (verwendbar ab 4 kHz) |
Measuring range |
-40 to +30 dBm |
RF voltmeter 2 + 3 (forward / reverse power) |
|
Connection |
2 x SMA |
Frequency range |
9 kHz bis 1.2 GHz (verwendbar ab 4 kHz) |
Measuring range |
-40 bis + 33 dBm + Richtungskoppler (typ. 40 dB) |
V. Video
***More videos on surge detectors and EMC measurement systems are available at: Gmga Measuring Youtube.No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide
Review Immunity test generator, Induction RF CDG 7000 HF 10kHz – 400MHz
There are no reviews yet.