I. Specification of PCE-HDM 20 digital multimeter
Infrared camera - TRMS digital multimeter for current, voltage, power, frequency and resistance / CAT IV 600 V / CAT III 1000 V / With infrared non-contact temperature measurement / MAX, MIN and HOLD functions.
- The PCE-HDM 20 power meter infrared imaging camera is a universal measuring instrument.
- The PCE-HDM 20 digital multimeter enables a wide range of measurement projects. This makes it easy for users to investigate current, voltage, capacitance, frequency, and resistance. In addition to these measurements, the infrared imaging camera can also perform measurements such as duty cycle, diode test, and continuity test.
- In addition to electrical parameters, the PCE-HDM 20 infrared imaging camera can also be used for temperature determination. The determination of temperature can be done in two different ways. In the first case, the temperature can be measured by plugging in the thermocouple. In the second case, the infrared imaging camera provides non-contact temperature measurement. For this purpose, an infrared lamp is installed on the infrared imaging camera, thus allowing the temperature to be determined from a distance. The thermal image is then clearly displayed on the screen.
- For a closer look, there are five different color palettes available, which can be selected as desired. To measure temperature by infrared sensor, the lamp helps to make darker areas brighter.
II. Advantages
- Auto off
- 2.8" LCD screen
- Built-in thermal imaging camera
- Thermal measurement via IR or thermocouple
- Measure resistance and check continuity
- Test diodes and measure capacitance.
III. Standard package
- Infrared imaging camera - PCE-HDM 20 digital multimeter
- 2 Measuring lines
- K-type thermocouple probe Type K
- Li-ion battery
- Charger
- Power socket
- 3 Plugs for power plugs
- Micro-SD Card (8 GB)
- Magnet
- Cloth ring
- Temperature adapter
- User manual.
IV. Specifications of PCE-HDM 20 digital multimeter
Temperature measurement with thermal imaging camera |
|
Sampling rate |
3 times per second |
Field of view (FOV) |
21° x 21°C / 0.5 m / 1 ft 7.6" |
Spatial resolution (IFOV) |
4.53 mrad |
Resolution infrared camera |
80 x 80 Pixel |
Thermal sensitivity / NETD |
<0.1°C (0.18°F) at 30°C (86°F) / 100 mK |
Frame rate |
50 Hz |
Focal length |
7.5 mm |
Sensor type |
uncooled microbolometer |
Spectral range |
8 ... 14 µm |
Measuring range object temperature |
-20 ... 260°C / -4 ... 500°F |
Measurement accuracy |
± 3°C / 5.4°F or 3% of the measured value, at 10 ... 35°C / 50 ... 95°F ambient temperature and > 0°C / 32°F object temperature |
General Technical Data |
|
Display |
Colour TFT, 6000 points with status display |
Conversion |
TRMS |
Reference standards |
IEC/EN61010-1, IEC/EN61326-1 |
Isolation |
Double |
Pollution degree |
2 |
Overload category |
CAT IV 600 V, CAT III 1000 V |
Battery type |
1 x 7.4V Li-Ion battery, 2300-mAh |
Power supply charger |
100 / 240V AC, 50/60 Hz, 10V DC, 1 A |
Battery level indicator |
Yes |
Automatic shutdown |
After 15, 30 or 60 minutes of inactivity (deactivatable) |
Fuses |
F10A/1000V, 10 x 38 mm (Input 10 A) |
F800mA/1000V, 6 x 32 mm (Input mA, µA) |
|
Test temperature |
18 ... 28°C / 64 ... 82°F |
Operating conditions |
5 ... 40°C / 41 ... 104°F, <80% r.H. |
Storage conditions |
-20 ... 60°C / -4 ... 140°F, <80% r.H. |
Maximum operating height |
2000 m / 2187 yd |
Dimensions |
175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in |
Weight |
540 g / 1 lb 3oz |
Technical Data DC Voltage |
||||
Measuring range |
Resolution | Measurement accuracy | Input resistance | Overload protection |
600 mV | 0.1 mV | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ |
1000V DC / ACrms |
6V |
0.001V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
60V | 0.01V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ |
1000V DC / ACrms |
600V |
0.1V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ | 1000V DC / ACrms |
1000V | 1V | ± (0.2% of measurement value + 5 Dgt) | >10 MΩ |
1000V DC / ACrms |
Technical Data AC Voltage (TRMS) |
||||
Measuring range |
Resolution | Measurement accuracy | Measurement accuracy |
Overload protection |
(50 ... 60 Hz) |
(61 Hz ... 1 kHz) |
|||
6V |
0.001V | ± (0.8% of measurement value +5 Dgt)± | (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
60V | 0.01V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
600V |
0.1V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
1000V | 1V | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
Technical Data DC and AC voltage (TRMS) |
||||
Measuring range |
Resolution | Measurement accuracy | Input resistance | Overload protection |
6V | 0.001V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ |
1000V DC / ACrms |
60V |
0.01V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ | 1000V DC / ACrms |
600V | 0.1V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ |
1000V DC / ACrms |
1000V |
1V | ± (2.4% of measurement value +20 Dgt) | >10 MΩ |
1000V DC / ACrms |
Technical Data Direct Current |
|||
Measuring range |
Resolution | Measurement accuracy | Overload protection |
600 µA | 0.1µA | ± (0.9% of measurement value +5 Dgt) |
Protection 800-mA / 1000 V |
6000 µA |
1 µA | ± (0.9% of measurement value +5 Dgt) | Protection 800-mA / 1000V |
60-mA | 0.01-mA | ± (0.9% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
600-mA |
0.1-mA | ± (0.9% of measurement value +8 Dgt) | Protection 800-mA / 1000V |
10:00 AM | 0.01 A | ± (1.5% of measurement value +5 Dgt) |
Protection 10 A / 1000V |
Technical Data Alternating Current (TRMS) |
|||
Measuring range |
Resolution | Measurement accuracy | Overload protection |
600 µA | 0.1 µA | ± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
6000 µA |
1 µA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V |
60-mA | 0.01-mA | ± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
600-mA |
0.1-mA | ± (1.2% of measurement value +5 Dgt) | Protection 800-mA / 1000V |
10:00 AM | 0.01 A | ± (1.5% of measurement value +5 Dgt) |
Protection 10 A / 1000V |
Technical Data Coil Current |
||||
Measuring range |
Resolution | Measurement accuracy | Measurement accuracy (61 Hz ... 1 kHz) |
Overload protection |
(50 ... 60 Hz) |
||||
30 A |
0.01 A | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) | 1000V DC / ACrms |
300 A | 0.1 A | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
3000 A |
1:00 AM | ± (0.8% of measurement value +5 Dgt) | ± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
Technical Data Diode Test |
|
Test current |
<1.5-mA |
Maximum voltage at the open circuit |
3.3V DC |
Resistance and continuity test |
||||
Measuring range |
Resolution | Measurement accuracy | Acoustic warning sound | Overload protection |
600 Ω | 0.1Ω | ± (0.5% of measurement value +10 Dgt) | >50 Ω |
1000V DC / ACrms |
6 Ω |
0.001 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
60 kΩ | 0.01 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω |
1000V DC / ACrms |
600 kΩ |
0.1 kΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω | 1000V DC / ACrms |
6 MΩ | 0.001 MΩ | ± (0.5% of measurement value +5 Dgt) | >50 Ω |
1000V DC / ACrms |
60 MΩ |
0.01 MΩ | ± (2.5% of measurement value +10 Dgt) | >50 Ω |
1000V DC / ACrms |
Technical Data Frequency |
|||
Measuring range |
Resolution | Measurement accuracy | Overload protection |
40 Hz ... 10 kHz | 0.01 Hz ... 0.001 kHz | ± (0.5% of measurement value) |
1000V DC / ACrms |
60 Hz |
0.01 Hz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms |
600 Hz | 0.1 Hz | ± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
6 kHz |
0.001kHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms |
60 kHz | 0.01kHz | ± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
600 kHz |
0.1 kHz | ± (0.09% of measurement value +5 Dgt) | 1000V DC / ACrms |
6 MHz | 0.001 MHz | ± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
10 MHz |
0.01 MHz | ± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
Technical Data Duty Cycle |
||
Measuring range |
Resolution | Measurement accuracy |
5 ... 95% | 0.10% |
± (1.2% of measurement value +2 Dgt) |
Technical Data Capacitance |
|||
Measuring range |
Resolution | Measurement accuracy | Overload protection |
60 nF | 0.01 nF | ± (1.5% of measurement value +20 Dgt) |
1000V DC / ACrms |
600 nF |
0.1 nF | ± (1.2% of measurement value +8 Dgt) | 1000V DC / ACrms |
6 µF | 0.001 µF | ± (1.5% of measurement value +8 Dgt) |
1000V DC / ACrms |
60 µF |
0.01 µF | ± (1.2% of measurement value +8 Dgt) | 1000V DC / ACrms |
600 µF | 0.1 µF | ± (1.5% of measurement value +8 Dgt) |
1000V DC / ACrms |
6000 µF |
1 µF | ± (2.5% of measurement value +20 Dgt) |
1000V DC / ACrms |
Technical Data Temperature (Thermoelement Type K) |
|||
Measuring range |
Resolution | Measurement accuracy | Overload protection |
-40 ... 600°C / -40 ... 1112°F | 0.1°C / 0.18°F | ± (1.5% of measurement value 3°C / 5.4°F) |
1000V DC / ACrms |
600 ... 1000°C / 1112°F ... 1832°F |
1°C / 1.8°F | ± (1.5% of measurement value 3°C / 5.4°F) |
1000V DC / ACrms |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review PCE-HDM 20 digital multimeter
There are no reviews yet.