Single-phase power meter MICROTEST 7120
Price: Contact
Model | 7110 / 7120 |
Manufacturer | MICROTEST |
Power supply | 100 ~ 240Vac/ 50/60Hz |
Weight | 1.85 Kg |
Size | 227x101x300 mm |
Condition | Stocking |
Warranty | 12 months |
Single-phase power meter MICROTEST 7120 can measure various parameters related to power supplies, including power, voltage, current, power factor, phase, and more. It is suitable for AC/DC and DC/DC power products.
I. Specifications of Desktop single-phase electricity meter MICROTEST 7120
Power meter MICROTEST 7120 provides a frequency bandwidth of 15Hz to 100kHz. MICROTEST 7120 supports up to 0th order harmonic analysis and has a maximum crest factor of 9 (CF9) for current waveforms.
- AC / DC Dual amp/watt-hour meter
- Wide range 0.001W-16KW
- Connection software attached
- Standby Power D.P.I. of 0.001W
- With crest factor ratio display
- Up to the 50 levels harmonic wave analysis capability
- 1000 sets of measurement data storage space
- Current crest factor is highest CF9.
Applications of Single-phase power meter MICROTEST 7120:
- The measurements are utilized in environmental monitors, energy saving lamps, exchangeable power supplies, transformers, uninterruptible power systems, power tools, 3C electronic products, and home appliances, etc.
Technical specifications of Single-phase power meter MICROTEST 7120
Model |
7110 |
7120 |
Frequency Range |
DC, 15Hz~10KHz |
DC, 15Hz~100KHz |
Harmonic (option) |
● / – |
● / – |
Measurement parameters:
Parameters |
Range |
Parameters |
Range |
Vrms |
0.1V ~ 600V |
PF |
0.000 ~ ±1.000 |
Vdc |
0.1V ~ 600V |
Deg |
-180°~ +180° |
Irms |
0.1mA ~ 20A |
THD |
0.01% ~ 99.99% |
Idc |
0.1mA ~ 20A |
Hz |
15Hz ~100kHz |
W |
0.01W ~16KW |
Measurement range:
Current (fixed/Auto) |
0.01A、0.03A、0.1A、0.3A、1A、3A、10A、20A |
Voltage (fixed/Auto) |
10V、30V、100V、300V、600V |
Harmonics SPEC:
Analysis base |
To achieved stable fundamental frequency analysis by voltage or current (non-inverter) |
Frequency Range 45Hz |
45Hz – 440Hz |
FFT Data Length |
1024 |
FFT Data Format |
32 bits |
Measurement |
1-50 THD, 1-50 level voltage and current V [n], A [n] |
Projects |
1-50 level voltage and current distortion percentage |
V [n%], A [n%] |
|
1-50 level watts W [n] |
|
1-50 level watts distortion percentage Watt W [n%] |
|
1-50 level voltage and current angle DEG [n] |
|
Vrms, Irms, Watt, PF |
Specifications:
Model |
7110 |
7120 |
Frequency Measurement Mode |
To achieved stable base frequency measurement (variation less than 1%) by voltage or current (non-inverter) |
|
Frequency Range |
DC, 15Hz~10KHz |
DC, 15Hz~100KHz |
Data Length |
Dual 4096×16 RAM for voltage & current |
|
ADC Resolution |
16 bits |
|
Sampling Rate |
AC 50Hz/60Hz basic sampling rate 100 KSPS /120 KSPS |
|
Arithmetic Precision |
Watt/VRMS/IRMS/MEAN/PF/Deg/Line filter 32bits |
|
Frequency Filter |
500Hz cut off, digital chip filter based on 25MHz |
|
Signal Filter |
500Hz-3db digital filter based on Butterworth 50Hz-0.03% reading, 60Hz-0.05% reading |
|
Frequency Acquisition Mode |
Voltage / current 100MHz baseband digital dynamic meter chip |
|
Phase Lead Detection |
Subject to the current, analog/digital hybrid detecting (error less than 5 degrees) |
RMS/MEAN Mode Voltage & Current Accuracy (23℃ ±5℃ ) |
|
>=15 Hz, f ≦ 45Hz |
±(0.1% of reading + 0.4% of range) |
>45 Hz, ≦ 66 Hz |
±(0.1% of reading + 0.1 % of range) |
>66 Hz, ≦ 1 kHz |
±(0.1% of reading + 0.2 % of range) |
>1 kHz, ≦ 10 kHz |
±(0.07*f % of reading + 0.3% of range) |
>10 kHz, ≦100 kHz |
±(0.5% of reading + 0.5% of range) ±[{0.04×(f–10)}% of reading] |
Funit is 1KHz |
|
When the AC is measured, if the fundamental frequency exceeds 200Hz, the F-Filter is required to be turned off in order to measure the most accurate value |
DC Mode Voltage & Current Accuracy (23℃ ±5℃ ) |
|
10V~600V |
±0.2% reading ± 0.2% of range |
0.01A ~20A |
±{(0.2)% of reading + 0.2 % of range} ±offset |
To add up the OFFSET errors of various files during measuring the DC current |
Power (W) Accuracy (23℃ ±5℃ ) |
|
AC power ranges (Auto or Manual)(40 ranges) range up to 16KW |
|
DC ±0.2% reading ± 0.5% of range |
|
Incidental Allowable Error Conditions |
|
Signal Filter Error (AC) |
– Frequency between 45-66Hz: Add 0.3% of reading. |
CF9 Error (DC) |
Add range tolerance * 3 |
Accuracy Effect of the Phase Error of the Power |
|
When the power factor PF is 0, the error range of Watt is |
|
Error within 12 months |
Add ±(0.5% of reading) |
System:
Model |
Support Harmonics |
Support Harmonics |
Don’t Support Harmonics |
Don’t Support Harmonics |
|
F71201 TEST BOX |
||
Built-in stroage |
6 Sets |
|
Power Supply |
Voltage |
100 ~ 240Vac |
Frequency |
50/60Hz |
|
Power consumption |
300VA |
|
Environment |
Temperature |
23℃±5℃ |
Humidity |
20%-80%RH |
|
Display |
Seven-segment display |
|
Dimension (W*H*D) |
227x101x300 mm |
|
Weight |
1.85 Kg |
|
Interface |
RS-232 (7110)、RS232 + GPIB (7120) |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Single-phase power meter MICROTEST 7120