Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D
Price: Contact
| Model | AC2 |
| Manufacturer | ESCO |
| Power supply | 115/230 VAC, 50/60 Hz |
| Weight | N/A |
| Size | N/A |
| Condition | Stocking |
| Warranty | 12 months |
Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D is equipped with Dual blower for inflow and downflow, which is a redundancy system that provides protection in the event of fan failure.
I. Specification Esco Airstream ® Gen 3 Class II (AC2) BSC Microbiological Safety Cabinets - D Series
Sentinel™ Gold Microprocessor Control System:
- Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D with audible and visual alarm
- Display all safety information on one screen
- The LCD display simultaneously shows time, airflow and airflow status, inlet and downflow velocities, and status comments.
- Multi-language: English, French, German, Spanish, Italian
- Diagnostic button, to easily check cabinet operating parameters and assist in maintenance.
- The large touchpad control buttons provide good tactile feedback.
- Color-coded LEDs: green for the fan; blue for FL lights and sockets; and orange for the UV lamp.
- Programmable UV lamp timer extends the life of the UV lamp.
- Centered and tilted down for easy access and viewing
- Selectable Quick Start mode for quick operation.

Energy-saving dual DC-ECM blower system:
- Esco Airstream ® Gen 3 (AC2) Class II Biological Safety Cabinets the most energy efficient BSC - D Series in the world, 70% energy saving compared to AC motors
- Stable airflow, despite voltage fluctuations and Loading filter
- Night setting mode to further reduce power consumption by 60%.

Filter ULPA:
- 10 times filtration efficiency compared to HEPA filter
- 99.999% at 0.1 to 0.3 microns, ULPA according to US IEST-RP-CC001.3 or >99.999% at MPPS, H14 according to EN 1822 EU
- Dual exhaust filter system for better protection, creating an ISO Class 3 workspace instead of the industry standard ISO Class 5
- Esco Airstream ® Gen 3 Class II (AC2) BSC - D Series cabinets use ULPA (according to IEST-RP-CC001.3) / H14 filter on EN 1822 instead of HEPA H13 filter used on many BSCs on the market.

Cabinet structure:
- Stainless steel side walls with side capture zones and negative pressure for optimized containment
- One-piece work tray, prevents spills and is easy to clean.

- Corners & Glass: Easy to clean, Sockets and service outlets easily accessible, Stainless steel sidewalls available (AC2-S and AC2-D variants).

- Split work tray: Easy to lift and clean, One-piece recessed tray available (AC2-S and AC2-D variants).

- Raise the armrest: Helps block the grille, comfortable working posture.

- Removable paper tray: Easy to clean, optional pre-filter can be installed.

Handy features:
- The angled front panel improves reach and comfort, reducing glare.
- Frameless, shatterproof shields are easier to clean, providing a larger, unobstructed viewing area.

Isocide ™ Antibacterial Powder Coating:
- Removes 99.9% of bacteria on surfaces within 24 hours of contact.

RS232 serial interface port:
- Send operational information to the Building Management System (BMS)
- Optional zero-volt warning and discharge contact.

Air flow sensor:
- Real-time airflow monitoring for safety
- Alerts the user if the airflow is not enough.

Dynamic Room ™:
- Ventilation space and side walls (AC2-S and AC2-D variants)
- Prevent pollutants from escaping.
ISOCIDE™ Coating:
- Silver ion impregnated powder coat
- Inhibits microbial growth for improved safety.

Cabinet filter system:
- Ambient air is drawn through the front grille to create an inlet without passing over the work surface. The inlet is joined by a downward half, to create a front air curtain that is fine-tuned to create a large performance envelope. The combined airflow passes through the rear air column towards the blower.
- About ⅓ of the air in the common room is expelled through the ULPA filter into the room. ⅔ remaining air is passed through a downflow ULPA filter and into the work area as a vertically layered air stream to create an ISO Class 3 work surface and prevent cross contamination.
- Near the work surface, the downflow separates. About Half is for the front grille, and half is for the rear grille. A small portion goes into the side snap areas to prevent dead air angles (small blue arrows).
- Optimized design for great performance, providing operator and product protection at wide Inflow and Downflow variations from Nominal point.
Standards compliance:
- Biological safety cabinets: EN 12469, Europe SANS 12469, South Africa
- Air quality: ISO 14644.1 Class 3, Worldwide JIS B9920 Class 3, Japan JIS BS 5295, Class 3, UK.
- Filter: EN-1822 (H14), Europe IEST-RP-CC001.3, USAIEST-RP-CC007, USA IEST-RP-CC034.1, USA.
- Electrical safety: IEC 61010-1, Worldwide EN 61010-1, Europe UL 61010-1, USA CAN / CSA-22.2, No.61010-1.
***For more detailed technical information, as well as select the appropriate model Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D; Please Contact GMGA. Our professional technicians are always ready to assist you 24/7.
II. Specifications Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D
TECHNICAL SPECIFICATIONS |
||||||
|
Glass Side: 230 VAC, 50/60 Hz |
AC2-2E8 2010718 |
AC2-3E8 2010658 |
AC2-4E8 2010621 |
AC2-5E8 2010656 |
AC2-6E8 2010657 |
|
| Glass Side: 115 VAC, 50/60 Hz | AC2-2E9 2010777 |
AC2-3E9 2010779 |
AC2-4E9 2010697 |
AC2-5E9 2010784 |
AC2-6E9 |
|
|
Stainless Steel Side: 230 VAC, 50/60 Hz |
AC2-2S8 2010767 |
AC2-3S8 2010721 |
AC2-4S8 2010711 |
AC2-5S8 2010725 |
AC2-6S8 2010722 |
|
| Stainless Steel Side: 115 VAC, 50/60 Hz | AC2-2S9 2010790 |
AC2-3S9 2010792 |
AC2-4S9 2010744 |
AC2-5S9 2010797 |
AC2-6S9 |
|
|
Nominal Size |
2 ft (0.6 meter) | 3 ft (0.9 meter | 4 ft (1.2 meter) | 5 ft (1.5 meter) | 6 ft (1.8 meter) | |
| External Dimensions (W x D x H) | Width | 730 mm (28.8") | 1035 mm (40.8") | 1340 mm (52.8") | 1645 mm (64.8") |
1950 mm (76.8") |
|
Depth without Arm Rest |
753 mm (29.5") | |||||
| Depth with Arm Rest |
810 mm (32.0") |
|||||
|
Height |
1400 mm (54.8") | |||||
| Gross Internal Dimensions (W x D x H) |
Width | 610 mm (24.0") | 915 mm (36.0") | 1220 mm (48.0") | 1525 mm (60.0") |
1830 mm (72.0") |
|
Depth |
580 mm (22.8") | |||||
| Height |
660 mm (26.0") |
|||||
|
Usable Work Area |
0.27 m2 (2.9 sq.ft.) |
0.42 m2 (4.5 sq.ft.) |
0.56 m2 (6.1 sq.ft.) |
0.71 m2 (7.63 sq.ft.) |
0.86 m2 (9.2 sq.ft.) |
|
| Tested Opening |
175 mm (7") |
|||||
|
Work Opening |
190 mm (7.5") | |||||
| Maximum Opening |
475 mm (18.7") |
|||||
|
Average Airflow |
Inflow | 0.45 m/s (90 fpm) | ||||
| Downflow |
0.30 m/s (60 fpm) |
|||||
|
Airflow Volume |
Inflow | 173 cmh (102 cfm) | 259 cmh (152 cfm) | 346 cmh (204 cfm) | 432 cmh (254 cfm) | 519cmh (305 cfm) |
| Downflow | 369 cmh (217 cfm) | 553 cmh (325 cfm) | 738 cmh (434 cfm) | 922 cmh (543 cfm) |
1107 cmh (657 cfm) |
|
|
Exhaust |
173 cmh (102 cfm) | 259 cmh (152 cfm) | 346 cmh (204 cfm) | 432 cmh (254 cfm) | 519cmh (305 cfm) | |
| Required Exhaust with Optional Thimble Exhaust Collar |
260 m3 /h (153 cfm) |
320 m3 /h (189 cfm) |
538 m3 /h (317 cfm) |
615 m3 /h (362 cfm) |
823 m3 |
|
|
Static Pressure for Optional |
28 Pa / 0.11 in H2 O |
29 Pa / 0.11 in H2 O |
31 Pa / 0.12 in H2 O |
35 Pa / 0.14 in H2 O |
47 Pa / 0.18 in H2 O |
|
| ULPA Filter Typical Efficiency |
>99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA |
|||||
|
>99.999% at MPPS, H14 as per EN 1822 EU |
||||||
| Sound Emission* | NSF / ANSI 49 | 56.3 | 56.6 | 58.7 | 58.2 |
59.4 |
|
EN 12469 |
51.0 | 52.0 | 53.5 | 53.6 | 55.7 | |
| Fluorescent Lamp Intensity (Lux) | 859 | 1279 | 1404 | 1227 |
1384 |
|
|
Fluorescent Lamp Intensity (foot-candles) |
80 | 119 | 130 | 114 | 129 | |
| Cabinet Construction | Main body |
1.2 mm (0.05") 18 gauge electro-galvanized steel with white oven-baked |
||||
|
Work Zone |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish | |||||
| Side Walls (E Series) |
UV-absorbing tempered glass, 5 mm (0.2"), colorless and transparent |
|||||
|
Side Walls (S Series) |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish |
|||||
| Electrical |
Cabinet Full Load Amps (FLA) |
1.8 A | 3.5 A | 3.7 A | 4.3 A | 5.5 A |
| Optional Outlets (FLA) |
5 A |
|||||
|
Heat Load (BTU/Hr) |
324 | 447 | 580 | 717 | 966 | |
| Nominal Power Consumption (W) | 95 | 131 | 160 | 210 |
283 |
|
|
Net Weight** |
116 Kg (256 lbs) | 173 Kg (381 lbs) | 230 Kg (507 lbs) | 288 Kg (635 lbs) | 346 Kg (763 lbs) | |
| Shipping Weight** | 143 Kg (315 lbs) | 214 Kg (472 lbs) | 285 Kg (628 lbs) | 356 Kg (785 lbs) |
428 Kg (944 lbs) |
|
|
Shipping Dimensions |
850 x 820 x 1760 mm (33.5" x 32.3" x 69.3") |
1120 x 820 x 1760 mm (44.1" x 32.3" x 69.3") |
1450 x 820 x 1760 mm (57.1" x 32.3" x 69.3") |
1720 x 820 x 1760 mm (67.7" x 32.3" x 69.3") |
2050 x 820 x 1760 mm (80.7" x 32.3" x 69.3") |
|
| Shipping Volume, Maximum** | 1.23 m3 (43.2 ft3) | 1.62 m3 (57.2 ft3) | 2.09 m3 (73.8 ft3) |
2.48 m3 (87.6 ft3) |
2.96 m3 (104.5 ft3) |
|
TECHNICAL SPECIFICATIONS |
|||
|
Glass Side: 230 VAC, 50/60 Hz |
AC2-4G8 2010734 |
AC2-6G8 2010743 |
|
| Stainless Steel Side: 230 VAC, 50/60 Hz | AC2-4D8 2010733 |
AC2-6D8 |
|
|
Nominal Size |
4 ft (1.2 meter) | 6 ft (1.8 meter) | |
| External Dimensions (W x D x H) | Width | 1340 mm (52.8") |
1950 mm (76.8") |
|
Depth without Arm Rest |
753 mm (29.5") | ||
| Depth with Arm Rest |
810 mm (32.0") |
||
|
Height |
1400 mm (54.8") | ||
| Gross Internal Dimensions (W x D x H) |
Width | 1220 mm (48") |
1830 mm (72") |
|
Depth |
580 mm (22.8") | ||
| Height |
660 mm (26.0") |
||
|
Usable Work Area |
0.56 m2 (6.1 sq.ft.) |
0.86 m2 (9.0 sq.ft.) |
|
| Tested Opening |
175 mm (7") |
||
|
Work Opening |
190 mm (7.5") | ||
| Maximum Opening |
475 mm (18.7") |
||
|
Average Airflow |
Inflow | 0.45 m/s (90 fpm) | |
| Downflow |
0.30 m/s (60 fpm) |
||
|
Airflow Volume |
Inflow | 346 cmh (588 cfm) | 519 cmh (881 cfm) |
| Downflow | 738 cmh (1254 cfm) |
1107 cmh (1880 cfm) |
|
| Exhaust | 346 cmh (588 cfm) | 519 cmh (881 cfm) | |
|
Required Exhaust with Optional |
538 m3 / h (317 cfm) |
823 m3 / h (485 cfm) |
|
| Static Pressure for Optional Thimble Exhaust Collar |
31 Pa / 0.12 in H2O |
47 Pa / 0.18 in H2O |
|
|
ULPA Filter Typical Efficiency |
>99.999% at 0.1 to 0.3 micron, ULPA as per IEST-RP-CC001.3 USA | ||
|
>99.999% at MPPS, H14 as per EN 1822 EU |
|||
|
Sound Emission* |
NSF / ANSI 49 | 61.3 dBA | 62.5 dBA |
| EN 12469 | 58.3 dBA |
59.5 dBA |
|
|
Fluorescent Lamp Intensity (Lux) |
1400 | ||
| Fluorescent Lamp Intensity (foot-candles) |
130 |
||
|
Cabinet Construction |
Main body | 1.2 mm (0.05") 18 gauge electro-galvanized steel with white oven-baked epoxy-polyester IsocideTM antimicrobial powder-coated finish |
|
| Work Zone |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish |
||
|
Side Walls (E Series) |
UV-absorbing tempered glass, 5 mm (0.2"), colorless and transparent | ||
| Side Walls (S Series) |
1.5 mm (0.06") 16 gauge stainless steel, type 304, with 4B finish |
||
|
Electrical |
Cabinet Full Load Amps (FLA) | 9.4 A | 12.6 A |
| Optional Outlets (FLA) |
5 A |
||
|
Heat Load (BTU/Hr) |
905 | 1230 | |
| Nominal Power Consumption (W) | 265 W |
360 W |
|
|
Net Weight** |
240 Kg (529 lbs) | 366 Kg (807 lbs) | |
| Shipping Weight** | 295 Kg (650 lbs) |
448 Kg (988 lbs) |
|
|
Shipping Dimensions |
1450 x 820 x 1760 mm (57.1" x 32.3" x 69.3") |
2050 x 820 x 1760 mm (80.7" x 32.3" x 69.3") |
|
| Shipping Volume, Maximum** | 2.09 m3 (73.8 ft3) |
2.96 m3 (104.5 ft3) |
|
AC2 Biological Safety Cabinet Engineering Drawing:

Optional Exhaust Collar Positions for Thimble-Ducting for AC2 Models:

III. Accessories for Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC - Series D
|
Accesories for AC2-G3 Biological Safety Cabinets |
|||||||
| Cabinet | Glass Side Wall | AC2-2E8 2010718 |
AC2-3E8 2010658 |
AC2-4E8 2010621 |
AC2-5E8 2010656 |
AC2-6E8 |
|
|
230 VAC, |
AC2-4G8 2010734 |
AC2-6G8 |
|||||
|
Stainless Steel Side Wall |
AC2-2S8 2010767 |
AC2-3S8 2010721 |
AC2-4S8 2010711 |
AC2-5S8 2010725 |
AC2-6S8 |
||
|
AC2-4D8 |
AC2-6D8 2010742 |
||||||
| Glass Side Wall | 115 VAC, 50/60 Hz |
AC2-2E9 2010777 |
AC2-3E9 2010779 |
AC2-4E9 2010697 |
AC2-5E9 2010784 |
AC2-6E9 |
|
|
Stainless Steel Side Wall |
AC2-2S9 2010790 |
AC2-3S9 2010792 |
AC2-4S9 2010744 |
AC2-5S9 2010797 |
AC2-6S9 |
||
|
Exhaust |
Anti-blowback Valve 10" | ABBV-10P 5170352 |
|||||
| Tri-safe Exhaust Collar with Alarm | N/A | TEM-4 2010606 |
N/A |
||||
|
Thimble Exhaust Collar |
ECO-AC22 5170520 |
ECO-AC23 5170521 |
ECO-AC24 5170522 |
ECO-AC25 5170523 |
ECO-AC26 5170524 |
||
| Work Zone | UV Lamp | UV-15A-L 5170251 |
UV-30A-L |
||||
|
IV Bar |
IV-605 5170498 |
IV-910 5170499 |
IV-1215 5170231 |
IV-1520 5170500 |
IV-1825 5170501 |
||
| Multiple Piece Tray Option (AC2-S / AC2-D) | SDT-AC2-2E 5020643 |
SDT-AC2-3E 5020635 |
SDT-AC2-4E 5020606 |
SDT-AC2-5E 5020640 |
SDT-AC2-6E |
||
|
Single Piece Tray Option (AC2-E / AC2-G) |
SGT-AC2-2S 5020696 |
SGT-AC2-3S 5020648 |
SGT-AC2-4S 5020627 |
SGT-AC2-5S 5020651 |
SGT-AC2-6S 5020645 |
||
| Pre-filter | PF-40 5090060 |
PF-41 5090061 |
PF-42 5090062 |
PF-43 5090063 |
PF-44 |
||
|
Electrical |
Direct Mounted / GFCI | EO-_ | |||||
| Service Fixtures |
EU SF-Gas-20 mm |
SF-1G20 5170410 |
|||||
|
EU SF-Vacuum-20 mm |
SF-1V20 5170457 | ||||||
| EU SF-Air-20 mm |
SF-1A20 5170502 |
||||||
|
EU SF-Nitrogen-20 mm |
SF-1N20 5170503 | ||||||
| EU SF-Water-20 mm |
SF-1W20 5170458 |
||||||
|
EU SF-Universal-22 mm |
SF-2U22 5170504 | ||||||
| Support Stands, Ships Flat |
Fixed Stand with Leveling Feet, 28” height |
SAL-2A0 Gen 2 5130169 |
SAL-3A0 Gen 2 5130170 |
SAL-4A0 Gen 2 5130134 |
SAL-5A0 Gen 2 5130171 |
SAL-6A0 Gen 2 |
|
|
Fixed Stand with Leveling Feet, |
SAL-2B0 Gen 2 5130173 |
SAL-3B0 Gen 2 5130174 |
SAL-4B0 Gen 2 5130175 |
SAL-5B0 Gen 2 5130176 |
SAL-6B0 Gen 2 5130177 |
||
| Fixed Stand with Caster Wheels, 28” height |
SPC-2A0 Gen 2 5130161 |
SPC-3A0 Gen 2 5130155 |
SPC-4A0 Gen 2 5130152 |
SPC-5A0 Gen 2 5130162 |
SPC-6A0 Gen 2 |
||
|
Fixed Stand with Caster Wheels, |
SPC-2B0 Gen 2 5130164 |
SPC-3B0 Gen 2 5130165 |
SPC-4B0 Gen 2 5130166 |
SPC-5B0 Gen 2 5130167 |
SPC-6B0 Gen 2 5130168 |
||
| Telescopic Stand with Leveling Feet, 1” adjustment |
STL-2A0 5130092 |
STL-3A0 5130050 |
STL-4A0 5130051 |
STL-5A0 5130052 |
STL-6A0 |
||
|
Telescopic Stand with Caster Wheels, |
STC-2A0 5130135 |
STC-3A0 5130055 |
STC-4A0 5130056 |
STC-5A0 5130057 |
STC-6A0 5130058 |
||
| Motorized Height Stand with Caster Wheels, 39.5” height |
SPM-3A2 5130093 |
SPM-4A2 5130047 |
SPM-5A2 5130100 |
SPM-6A2 |
|||
|
Misc |
IQ/OQ Protocol |
9010179 |
|||||
IV. Video
***See more videos of microbiological safety cabinets Class I, Class II, Class III at: Gmga Measuring Youtube.
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide


Review Esco Airstream® biological safety cabinet Gen 3 Class II (AC2) BSC – Series D
There are no reviews yet.