Mutant conflict generator CWG 1500
Price: Liên hệ
Model | CWG 1500 |
Manufacturer | Schlöder GmbH |
Power supply | |
Weight | |
Size | |
Condition | Còn hàng |
Warranty | 12 tháng |
I. Specification of Mutant conflict generator CWG 1500

- The Surge / Hybrid CWG 1500 test generator simulates high energy disturbances and is suitable for performing EMC tests on systems and systems according to IEC 61000-4-5, 2014; DIN EN 61000-4-5, 2014 and VDE 0847-4-5.
- The CWG 1500 Schlöder surge generator is a combined surge current/voltage generator and produces a standard surge voltage with a 1.2/50 s curve shape and a standard surge current with a 8/20µs curve at idling.
- Values for current and voltage are displayed, for ratings with oscilloscopes, BNC outputs for current and voltage are available on the back panel. With the integrated single-phase multiplexing network, the output pulses/noise variables of the hybrid generator can be coupled to the arcs of the equipment under test.
- All parameters can be set easily and clearly. With the memory button, 32 settings can be activated directly. Control via computer is also possible via serial interface.
- Measure against each other: The Mutant conflict generator CWG 1500 Schlöder surge generator has 3 relationships with each other and the difference between them and others. Value categories for phones and phones, appliances, devices, knives and knives, and out.
- Your hardware and hardware. Using our software, it is possible to have.
II. Parameter definition - IEC 61000-4-5
Stirnzeit / Front time Tr µs |
Duration Td µs |
|
Open circuit voltage |
Tf = 1,67 x T = 1,2 ± 30 % | Td = Tw = 50 ± 20 % |
Short-circuit current | Tf = 1,25 x Tr = 8 ± 20 % |
Td = 1,18 x Tw = 20 ± 20 % |

III. Specifications of Surge/ Hybrid CWG 1500 generator

Generator |
|
[6] Charging voltage |
0.2 - 4.4 kV |
[4] Display |
Discharge / surge voltage |
Waveform 1.2 / 50 µs |
|
(IEC 61000-4-5) |
|
[5] Display |
Discharge / surge current |
Waveform 8/20 µs |
|
(IEC 61000-4-5) |
|
[17] Polarity |
Positive, negative, alternating |
sp. Energy |
100 Ws max. |
Charging time |
≤ 10 sec |
HV output |
Ungrounded or earth-related |
General functions |
[11] adjustment via potentiometer for |
[6] open circuit voltage |
|
[7] phase angle |
|
[13] Number of pulses |
|
[12] Repetition rate |
|
[1] Surge function on / off |
|
[9] Enable remote control via RS 232 |
|
[10] RS 232 interface |
|
[15] Trigger |
Manual or external |
[7] Phase angle for |
ϕ = 0 - 359 °, step 1 ° grid synchron. Triggering |
[13] Number of pulses1 - 999 |
1 - 999 |
[12] Repetition rate |
10 - 990 sec |
[14] Dischargeunloading the |
Unloading the |
Energy storage / STOP |
|
[16] Charge |
Loading the |
Energy storage |
|
[8] Memory function |
Call up test levels 1-4; |
A maximum of 32 memories can be freely selected |
|
Rear |
HV output for connecting the 3-phase coupling network |
Dimensions |
19 "housing, 3 U |
Weight |
approx. 18 kg |
Electronics input |
100-240 V / 47-63 Hz / 100 VA |
Coupling network |
|
Nominal voltage |
230 V / 50/60 Hz or 270 V DC |
Nominal current |
16 A AC or DC |
[3] symmetrical coupling Asym. Coupling |
L - N: 18 µF |
L - PE, N - PE: 9 µF + 10 Ω |
|
[18] EUT connection |
Schuko |
[19] EUT connection |
Additional laboratory sockets |
[20] Earth connection |
Socket at the front and at the rear |
[2] Phase display |
Red / green lamp |
Options |
|
CWG 520 (4x16 A) |
3-phase network, B + S |
CWG 523 (4x32 A) |
3-phase network, B + S |
CWG 524 (4x60 A) |
3-phase network, B + S |
CWG 1526-4 (4A) |
CDN for 2 data lines |
CWG 1526-10 (10 A) |
CDN for 2 data lines |
CWG 1528 (6 A) |
CDN 4 data cable, RS 232 |
CWG 550 |
18 µF cond. in the housing |
EMV-SOFT |
Control software |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide
Review Mutant conflict generator CWG 1500
There are no reviews yet.