Mutant conflict generator CWG 1500

Buyer Rates Mã sản phẩm: 17059

Model: CWG 1500
Manufacturer: Schlöder
Status: Stocking
Guarantee: 12 months
Price: Contact

The CWG 1500 Schlöder surge generator simulates high energy noise pulses and is suitable for performing EMC tests on systems and systems according to IEC 61000-4-5, 2014; DIN EN 61000-4-5, 2014 and VDE 0847-4-5. The CWG 1500 is a combined boost voltage/current generator and produces a standard surge voltage with a 1.2/50 µs curve shape and a standard surge current with an 8/20 µs curve shape when idling.

  • Voltage pulse shape: 1.2 / 50µs
  • Amplitude: 0.2 – 4.4 kV
  • Current pulse shape: 8/20µs
  • Amplitude: 0.1-2.2 kA.

Description

I. Specification of Mutant conflict generator CWG 1500

Mutant conflict generator CWG 1500

  • The Surge / Hybrid CWG 1500 test generator simulates high energy disturbances and is suitable for performing EMC tests on systems and systems according to IEC 61000-4-5, 2014; DIN EN 61000-4-5, 2014 and VDE 0847-4-5.
  • The CWG 1500 Schlöder surge generator is a combined surge current/voltage generator and produces a standard surge voltage with a 1.2/50 s curve shape and a standard surge current with a 8/20µs curve at idling.
  • Values ​​for current and voltage are displayed, for ratings with oscilloscopes, BNC outputs for current and voltage are available on the back panel. With the integrated single-phase multiplexing network, the output pulses/noise variables of the hybrid generator can be coupled to the arcs of the equipment under test.
  • All parameters can be set easily and clearly. With the memory button, 32 settings can be activated directly. Control via computer is also possible via serial interface.
  • Measure against each other: The Mutant conflict generator CWG 1500 Schlöder surge generator has 3 relationships with each other and the difference between them and others. Value categories for phones and phones, appliances, devices, knives and knives, and out.
  • Your hardware and hardware. Using our software, it is possible to have.

II. Parameter definition – IEC 61000-4-5

Stirnzeit / Front time Tr µs

Duration Td µs

Open circuit voltage

Tf = 1,67 x T = 1,2 ± 30 % Td = Tw = 50 ± 20 %
Short-circuit current Tf = 1,25 x Tr = 8 ± 20 %

Td = 1,18 x Tw = 20 ± 20 %

CWG-1500-Schlöder

***See more of Gmga’s surge detectors and EMC measurement systems at: https://gmga.vn/en/danh-muc/maintenance-equipment/surge-generators-and-emc-measuring-systems/

III. Specifications of Surge/ Hybrid CWG 1500 generator

Mutant conflict generator CWG 1500

Generator

[6] Charging voltage

0.2 – 4.4 kV
[4] Display

Discharge / surge voltage

 Waveform 1.2 / 50 µs

  (IEC 61000-4-5)

[5] Display

Discharge / surge current

 Waveform 8/20 µs

   (IEC 61000-4-5)

[17] Polarity

Positive, negative, alternating

  sp. Energy

100 Ws max.
  Charging time

≤ 10 sec

  HV output

Ungrounded or earth-related
 General functions

[11] adjustment via potentiometer for

 [6] open circuit voltage

 [7] phase angle

[13] Number of pulses

 [12] Repetition rate

 [1] Surge function on / off

[9] Enable remote control via RS 232

[10] RS 232 interface

[15] Trigger

Manual or external

[7] Phase angle for

ϕ = 0 – 359 °, step 1 ° grid synchron. Triggering
[13] Number of pulses1 – 999

1 – 999

[12] Repetition rate

10 – 990 sec
[14] Dischargeunloading the

Unloading the

Energy storage / STOP

[16] Charge

Loading the

Energy storage

[8] Memory function

Call up test levels 1-4;

 A maximum of 32 memories can be freely selected

Rear

HV output for connecting the 3-phase coupling network

Dimensions

19 “housing, 3 U
Weight

approx. 18 kg

Electronics input

100-240 V / 47-63 Hz / 100 VA

Coupling network

Nominal voltage

230 V / 50/60 Hz or 270 V DC
Nominal current

16 A AC or DC

[3] symmetrical coupling
Asym. Coupling

L – N: 18 µF

L – PE, N – PE: 9 µF + 10 Ω

[18] EUT connection

Schuko
[19] EUT connection

Additional laboratory sockets

[20] Earth connection

Socket at the front and at the rear
[2] Phase display

Red / green lamp

Options

CWG 520 (4×16 A)

3-phase network, B + S
CWG 523 (4×32 A)

3-phase network, B + S

CWG 524 (4×60 A)

3-phase network, B + S
CWG 1526-4 (4A)

CDN for 2 data lines

CWG 1526-10 (10 A)

CDN for 2 data lines
CWG 1528 (6 A)

CDN 4 data cable, RS 232

CWG 550

18 µF cond. in the housing
EMV-SOFT

Control software

 

***Videos of surge detectors and EMC measurement systems are available at: Gmga Measuring Youtube.