TXgard-IS+ toxic gas detector
Price: Contact
| Model | TXgard-IS+ |
| Manufacturer | CROWCON |
| Power supply | 8-32VDC/ 4-20mA |
| Weight | 0.7 Kg |
| Size | 160 x 123 x 92 mm |
| Condition | Stocking |
| Warranty | 12 months |
The TXgard-IS+ toxic gas detector is ATEX certified for use in Zone 0.1 or 2 hazardous areas and is also UL and cUL certified for use in Zone 1 or 2 hazardous areas.
I. Specification of toxic gas detector TXgard-IS+

Non-intrusive calibration:
- Calibration of the TXgard-IS+ toxic gas and toxic gas detectors can be performed on-site without the need for a hot work permit - minimizing downtime.
- Local display and buttons allow calibration without opening the junction box.
Flexible output options:
- 4-20mA current power supply - works with a wide selection of control boards.
- 2-wire format.
Sure and reliable:
- Made from carbon-loading nylon
- Ingress protection according to IP65.
Low cost:
- Non-intrusive calibration - easy to operate and maintain
- Long-life sensor - keep on-site operation to a minimum
- Simple spare parts replacement.
A wide range of sensors:
- TXgard-IS+ Crowcon toxic gas detector with wide range of electrochemical sensors for toxic gases and oxygen.
***See more GMGA stationary gas detectors and analyzers at: https://gmga.vn/en/danh-muc/analytical-equipment/gas-analysis-equipment/
II. Specifications of oxygen detector TXgard-IS+
| Specifications | |
| Size | 160 x 123 x 92mm |
| (6.3 x 4.8 x 4.5ins) | |
| Weight | 0.7kg (1.5lbs) |
| Ingress protection | IP65 |
| Enclosure material | Junction box: Carbon loaded nylon |
| Sensor housing: ABD Plastic | |
| Power | 8-32Vdc, 4-20mA loop-powered |
| Cable entries | 1 x M20 or 1/2” NPT with adaptor |
| Operating temperature | -20°C to +55°C (-4°F to 132°F) * |
| Humidity | 15 to 90% RH non-condensing |
| Display | 2-Line, 16 character LCD |
| Calibration method | Via push-buttons |
| Electrical output | 2 wire 4-20mA sink |
| Terminals | Suitable for up to 2.5mm2 cable |
| Sensor type | Electrochemical |
| Repeatability | +/- 2% FSD typically |
| Zero drift | +/- 2% FSD, 6 months typically |
| Response time | Contact Crowcon for a full list of sensor response times |
| Performance | Tested in accordance with EN60079-29-1 |
| Hazardous area zones | Zone 0, 1 or 2 |
| Division 1 or 2 | |
| (when connected via an isolation device) | |
| Approvals | Ex II 1 G Ex ia IIC T4 (-40°C to +65°C) |
| Exia IIC T4 Gb Tamb -20°C to +55°C | |
| UL Class I, groups A, B, C and D | |
| EMC compliance | EN 50270, FCC: CFR 47 Part 15, ICES-003 |
| * Figures shown exclude the sensors – Please contact Crowcon for a full list of sensor operating temperatures | |
Gas And Range |
|
|
Gas |
Range Available |
| Ammonia (NH3) |
50, 100, 1000ppm |
|
Chlorine (Cl2) |
5, 10, 20ppm |
| Carbon monoxide (CO) |
250, 500ppm |
|
Chlorine dioxide (ClO2) |
1ppm |
| Hydrogen (H2) |
2000ppm, 50% LEL, 100% LEL |
|
Hydrogen cyanide (HCN) |
25ppm |
| Hydrogen sulphide (H2S) |
25, 50, 100, 200ppm |
|
Hydrogen fluoride (HF) |
10ppm |
| Nitrogen dioxide (NO2) |
10ppm |
|
Oxygen (O2) |
25% vol. |
| Ozone (O3) |
1ppm |
|
Phosgene (COCl2) |
1ppm |
| Phosphine (PH3) |
2ppm |
|
Sulphur dioxide (SO2) |
10, 20, 30ppm |
***Crowcon's toxic gas detector video is available at: Gmga Measuring Youtube.
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

COMMIT
100% new product

COMMIT
100% refund if the product is of bad quality and not as promised

DELIVERY
Nationwide


Review TXgard-IS+ toxic gas detector
There are no reviews yet.