TXgard-IS+ toxic gas detector
Price: Liên hệ
Model | TXgard-IS+ |
Manufacturer | Crowcon |
Power supply | |
Weight | |
Size | |
Condition | Còn hàng |
Warranty | 12 tháng |
The TXgard-IS+ toxic gas detector is ATEX certified for use in Zone 0.1 or 2 hazardous areas and is also UL and cUL certified for use in Zone 1 or 2 hazardous areas.
***Crowcon's toxic gas detector video is available at: Gmga Measuring Youtube.
I. Specification of toxic gas detector TXgard-IS+

Non-intrusive calibration:
- Calibration of the TXgard-IS+ toxic gas and toxic gas detectors can be performed on-site without the need for a hot work permit - minimizing downtime.
- Local display and buttons allow calibration without opening the junction box.
Flexible output options:
- 4-20mA current power supply - works with a wide selection of control boards.
- 2-wire format.
Sure and reliable:
- Made from carbon-loading nylon
- Ingress protection according to IP65.
Low cost:
- Non-intrusive calibration - easy to operate and maintain
- Long-life sensor - keep on-site operation to a minimum
- Simple spare parts replacement.
A wide range of sensors:
- TXgard-IS+ Crowcon toxic gas detector with wide range of electrochemical sensors for toxic gases and oxygen.
II. Specifications of oxygen detector TXgard-IS+
Specifications | |
Size | 160 x 123 x 92mm |
(6.3 x 4.8 x 4.5ins) | |
Weight | 0.7kg (1.5lbs) |
Ingress protection | IP65 |
Enclosure material | Junction box: Carbon loaded nylon |
Sensor housing: ABD Plastic | |
Power | 8-32Vdc, 4-20mA loop-powered |
Cable entries | 1 x M20 or 1/2” NPT with adaptor |
Operating temperature | -20°C to +55°C (-4°F to 132°F) * |
Humidity | 15 to 90% RH non-condensing |
Display | 2-Line, 16 character LCD |
Calibration method | Via push-buttons |
Electrical output | 2 wire 4-20mA sink |
Terminals | Suitable for up to 2.5mm2 cable |
Sensor type | Electrochemical |
Repeatability | +/- 2% FSD typically |
Zero drift | +/- 2% FSD, 6 months typically |
Response time | Contact Crowcon for a full list of sensor response times |
Performance | Tested in accordance with EN60079-29-1 |
Hazardous area zones | Zone 0, 1 or 2 |
Division 1 or 2 | |
(when connected via an isolation device) | |
Approvals | Ex II 1 G Ex ia IIC T4 (-40°C to +65°C) |
Exia IIC T4 Gb Tamb -20°C to +55°C | |
UL Class I, groups A, B, C and D | |
EMC compliance | EN 50270, FCC: CFR 47 Part 15, ICES-003 |
* Figures shown exclude the sensors – Please contact Crowcon for a full list of sensor operating temperatures |
Gas And Range |
|
Gas |
Range Available |
Ammonia (NH3) |
50, 100, 1000ppm |
Chlorine (Cl2) |
5, 10, 20ppm |
Carbon monoxide (CO) |
250, 500ppm |
Chlorine dioxide (ClO2) |
1ppm |
Hydrogen (H2) |
2000ppm, 50% LEL, 100% LEL |
Hydrogen cyanide (HCN) |
25ppm |
Hydrogen sulphide (H2S) |
25, 50, 100, 200ppm |
Hydrogen fluoride (HF) |
10ppm |
Nitrogen dioxide (NO2) |
10ppm |
Oxygen (O2) |
25% vol. |
Ozone (O3) |
1ppm |
Phosgene (COCl2) |
1ppm |
Phosphine (PH3) |
2ppm |
Sulphur dioxide (SO2) |
10, 20, 30ppm |