Xgard Bright fixed toxic gas sensor
Price: Liên hệ
Model | Xgrad Bright |
Manufacturer | Crowcon |
Power supply | |
Weight | |
Size | |
Condition | Còn hàng |
Warranty | 12 tháng |
I. Specification Xgard Bright fixed toxic gas sensor
Generality:
- This flame retardant (Exd) toxic gas detector is housed in a premium aluminum alloy housing. Certifications including gas and dust approvals for ATEX and IECEX with UL gas certification in progress.
Versatile:
- Xgard Bright Crowcon stationary toxic gas sensor monitors flammable and toxic oxygen and toxic gases - Reduces training requirements on systems.
- Choice of M20 or NPT connection - Supports multiple system requirements
- Low Power Requirements (up to 3W) - Reduces system-wide energy consumption
- IP65 or IP66 rated (with weatherproof cover) - Allows use in areas subject to frequent washing or exposure.
Easy to install and operate:
- Addressing - Dramatically reduces the amount of cabling required for multisite installations
- Local Display - Provides gas level indication, status and maintenance routine support
- Non-Intrusive Calibration - with Xgard Bright Crowcon fixed toxic gas sensor eliminating the need to open the lid for calibration
- Plug in type terminal blocks: Makes wiring quick and easy to reduce installation costs
- Configuration via magnetic lock - Reduces the amount of time the operator spends in the hazardous area.
II. Specifications of Xgard Bright flame retardant toxic gas detector (Exd)
Size | 156 x 166 x 109mm (6.1 x 6.5 x 4.3inch) |
Cable Entry | 2x M20 (stopping plug fitted to left-side entry) |
Power | 10-30Vdc. 3W max |
Electrical Output | 4-20mA current sink or source |
RS-485 Modbus RTU | |
HART (Optional) | |
Weight | Aluminium alloy 1kg (2.2lbs) |
Enclosure Material | ADC 12 aluminium alloy |
Relay | Alarm 1, Alarm 2, Fault |
SPST contacts rated 1A 30Vdc | |
Sounder Out | 24Vdc (nominally), 250mA maximum load |
Operating Temperature | -40°C to +70°C (-40°F to 158°F) |
Note: sensor operating temperatures vary widely. | |
Refer to the sensor module datasheet or contact | |
Crowcon for specific sensor data. | |
Humidity | 0 to 95% RH, non-condensing |
Repeatability | +/- 2% FSD |
Zero drift | +/- 2% FSD per year maximum |
Ingress protection | IP65 (IP66 with weatherproof cap) |
Approvals | ATEX and IECExEx II 2 G Ex db IIC T6 Gb |
Ex tb IIIC T80ᶜ Db | |
II 2 G Ex db IIC T6 Gb | |
II 2 D Ex tb IIIC T80ᶜ Db | |
Certificate numbers: | |
TUV 16 ATEX 7908 X | |
IECEx TUR16.0035 X | |
EMC Compliance | EN50270: 2015 |
Standards | EN60079-0 :2012 + A11:2013 |
EN60079-1 :2014 | |
IEC60079-0 :2011 Edition 6 | |
IEC60079-1 :2014 Edition 7 | |
Zones | Certified for use in Zone 1 and Zone 2 areas |
Gas And Range |
||||||
Gas |
Units | Max | Standard | Alarm 1 | Alarm 2 | Temp |
Range | Range | level | level |
range °C |
||
Oxygen (O2) |
%Vol | 30 | 25 | 19 (falling) | 17 (falling) | -20 to +50 |
Carbon Monoxide (CO) | PPM | 1000 | 250 | 30 | 200 |
-30 to +50 |
Hydrogen Sulphide (H2S) |
PPM | 100/200 | 25 | 5 | 10 | -30 to +50 |
Hydrogen (H2) | %LEL | 100 | 100 | 20 | 40 |
-40 to +75 |
Methane (CH4) |
%LEL | 100 | 100 | 20 | 40 | -40 to +75 |
Pentane (C5H12) | %LEL | 100 | 100 | 20 | 40 |
-40 to +75 |
LPG |
%LEL | 100 | 100 | 20 | 40 | -40 to +75 |
Carbon Dioxide (CO2) | %VOL | 0-5% | 0-5% | 0-2% | 0-3% |
-20 to +50 |
III. Video
***See more videos of Crowcon fixed toxic gas sensors at: Gmga Measuring Youtube.No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Xgard Bright fixed toxic gas sensor