CAN data logger single-channel Kvaser Memorator Light HS v2

Price: Contact

Model EAN: 73-30130-01058-1
Manufacturer Kvaser
Power supply PC Interface USB
Weight 150 g
Size 46 x 127 x 22 mm
Condition Stocking
Warranty 24 months

CAN data logger single-channel Kvaser Memorator Light HS v2 (EAN: 73-30130-01058-1) automatically determines the correct CAN bus bit rate, removing the need for configuration – just plug and play.

Also, the Kvaser Memorator Light HS v2 has a built-in flash disk that cannot be accidentally lost, misplaced, or mixed up with other disks.

I. Major features of CAN data logger Kvaser Memorator Light HS v2

  • Data logger
  • Single high-speed CAN channel (compliant with ISO 11898-2).
  • Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
  • Quick and easy "plug-and-play" installation.
  • Pre-configured data logging.
  • Runs in silent mode – logs bus traffic without interference.
  • Automatically adjusts to the CAN bus signaling rate (autobaud feature).
  • Logger status is indicated with externally visible LEDs.
  • Fixed 1 GB internal disk.
  • Data logger with two fixed-size ring buffers – one for all messages, and one for error frames with pre- and post-trigger buffers.
  • Built-in real time clock (calendar) with battery backup.
  • Fully compatible with J1939, CANopen, NMEA 2000® and DeviceNet.

II. Software

  • Documentation, Kvaser CANlib SDK and drivers can be downloaded for free at: www.kvaser.com/downloads.
  • Kvaser CANlib SDK is a free resource that includes everything you need to develop soſtware for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Visual Basic, Python and t programming language.
  • Kvaser CAN hardware is built around the same common soſtware API. Applications developed using one device type will run without modification on other device types

III. Kvaser Memorator Light HS v2 hardware

Hardware installation:

  • For the Kvaser Memorator Light HS v2 to communicate with the host computer, a compatible version of the Kvaser driver and firmware must be installed.
  • After the driver has been installed on the host computer, the firmware may then be downloaded and installed on the Kvaser Memorator Light HS v2.
  • The latest version of the driver and firmware can be downloaded from: www.kvaser.com/download.
  • The driver is installed by running the file: kvaser_drivers_setup.exe.
  • The Kvaser Memorator Light HS v2 may be inserted in any free USB socket on the host computer. You do not need to switch the power off before inserting or removing the device.

USB connector:

  • The Kvaser Memorator Light HS v2 has a standard USB type “B” female connector. Connect the device to your computer using any high quality USB 2.0 certified cable. The maximum total USB cable length is 5 m (∼ 16 ft).

CAN channels:

  • The Kvaser Memorator Light HS v2 has one CAN Hi-Speed channel with a 9-pin D-SUB CAN connector.
  • The Kvaser Memorator Light HS v2 can be powered through the CAN connector or through the USB connector.
  • To operate the Kvaser Memorator Light HS v2 in logger mode, you must supply power through the CAN connector. To configure the device, power the device via USB.
  • The Kvaser Memorator Light HS v2 contains a battery that needs to be fully charged before using the device for the first time. Connect the Kvaser Memorator Light HS v2 to either a powered USB port or supply power through the CAN connector and let the battery charge overnight.
  • The battery inside the Kvaser Memorator Light HS v2 is used for powering the real time clock and ensuring a safe shutdown of the device when disconnected.

Flash disk:

  • The disk in the Kvaser Memorator Light HS v2 is permanently installed inside the device and cannot be replaced by the user.

LED indicators:

  • The Kvaser Memorator Light HS v2 is equipped with four LED indicators. The following tables describe the status functions of the LEDs.

LED

General meaning

PWR (Green)

Power and general status

CAN (Yellow)

Status for CAN channel

ERR FR (Yellow)

Error frames, and FIFO status

ERR (Red)

Indicates temporary or permanent errors

Technical data of CAN data logger single-channel Kvaser Memorator Light HS v2

CAN Channels

1

CAN Transceivers

MCP2561FD (Compliant with ISO 11898-2)

CAN Controller

Kvaser CAN IP in FPGA

Galvanic isolation

No

CAN Bit Rate

50 kbit/s to 1 Mbit/s

CAN FD Bit Rate

Up to 8 Mbit/s (with correct physical layer implementation)

Time stamp resolution

2 μs

Max message rate

20000 msg/s per channel

Error Frame Detection

Yes

Error Frame Generation

No

Silent mode

Yes – Always on

Kvaser MagiSync

No

Kvaser CANtegrity

No

Host interface

USB 2.0

Host OS

Windows (7 or later), Linux, Android.

External power

9–40 V

Power consumption

Up to 3W

Hardware configuration

Done by software (Plug & Play).

Dimensions

46 x 127 x 22 mm for body incl. strain relief

Weight

150 g

Operating temperature

−40 ◦C to +85 ◦C

Storage temperature

−40 ◦C to +85 ◦C

Relative humidity

0 % to 85 % (non-condensing.)

Review CAN data logger single-channel Kvaser Memorator Light HS v2

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review CAN data logger single-channel Kvaser Memorator Light HS v2
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide

      OTHER SAME PRODUCTS