CAN data logger single-channel Kvaser Memorator Light HS v2
Price: Contact
Model | EAN: 73-30130-01058-1 |
Manufacturer | Kvaser |
Power supply | PC Interface USB |
Weight | 150 g |
Size | 46 x 127 x 22 mm |
Condition | Stocking |
Warranty | 24 months |
CAN data logger single-channel Kvaser Memorator Light HS v2 (EAN: 73-30130-01058-1) automatically determines the correct CAN bus bit rate, removing the need for configuration – just plug and play.
Also, the Kvaser Memorator Light HS v2 has a built-in flash disk that cannot be accidentally lost, misplaced, or mixed up with other disks.
I. Major features of CAN data logger Kvaser Memorator Light HS v2
- Data logger
- Single high-speed CAN channel (compliant with ISO 11898-2).
- Supports both 11-bit (CAN 2.0A) and 29-bit (CAN 2.0B active) identifiers.
- Quick and easy "plug-and-play" installation.
- Pre-configured data logging.
- Runs in silent mode – logs bus traffic without interference.
- Automatically adjusts to the CAN bus signaling rate (autobaud feature).
- Logger status is indicated with externally visible LEDs.
- Fixed 1 GB internal disk.
- Data logger with two fixed-size ring buffers – one for all messages, and one for error frames with pre- and post-trigger buffers.
- Built-in real time clock (calendar) with battery backup.
- Fully compatible with J1939, CANopen, NMEA 2000® and DeviceNet.
II. Software
- Documentation, Kvaser CANlib SDK and drivers can be downloaded for free at: www.kvaser.com/downloads.
- Kvaser CANlib SDK is a free resource that includes everything you need to develop soſtware for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Visual Basic, Python and t programming language.
- Kvaser CAN hardware is built around the same common soſtware API. Applications developed using one device type will run without modification on other device types
III. Kvaser Memorator Light HS v2 hardware
Hardware installation:
- For the Kvaser Memorator Light HS v2 to communicate with the host computer, a compatible version of the Kvaser driver and firmware must be installed.
- After the driver has been installed on the host computer, the firmware may then be downloaded and installed on the Kvaser Memorator Light HS v2.
- The latest version of the driver and firmware can be downloaded from: www.kvaser.com/download.
- The driver is installed by running the file: kvaser_drivers_setup.exe.
- The Kvaser Memorator Light HS v2 may be inserted in any free USB socket on the host computer. You do not need to switch the power off before inserting or removing the device.
USB connector:
- The Kvaser Memorator Light HS v2 has a standard USB type “B” female connector. Connect the device to your computer using any high quality USB 2.0 certified cable. The maximum total USB cable length is 5 m (∼ 16 ft).
CAN channels:
- The Kvaser Memorator Light HS v2 has one CAN Hi-Speed channel with a 9-pin D-SUB CAN connector.
- The Kvaser Memorator Light HS v2 can be powered through the CAN connector or through the USB connector.
- To operate the Kvaser Memorator Light HS v2 in logger mode, you must supply power through the CAN connector. To configure the device, power the device via USB.
- The Kvaser Memorator Light HS v2 contains a battery that needs to be fully charged before using the device for the first time. Connect the Kvaser Memorator Light HS v2 to either a powered USB port or supply power through the CAN connector and let the battery charge overnight.
- The battery inside the Kvaser Memorator Light HS v2 is used for powering the real time clock and ensuring a safe shutdown of the device when disconnected.
Flash disk:
- The disk in the Kvaser Memorator Light HS v2 is permanently installed inside the device and cannot be replaced by the user.
LED indicators:
- The Kvaser Memorator Light HS v2 is equipped with four LED indicators. The following tables describe the status functions of the LEDs.
LED |
General meaning |
PWR (Green) |
Power and general status |
CAN (Yellow) |
Status for CAN channel |
ERR FR (Yellow) |
Error frames, and FIFO status |
ERR (Red) |
Indicates temporary or permanent errors |
Technical data of CAN data logger single-channel Kvaser Memorator Light HS v2
CAN Channels |
1 |
CAN Transceivers |
MCP2561FD (Compliant with ISO 11898-2) |
CAN Controller |
Kvaser CAN IP in FPGA |
Galvanic isolation |
No |
CAN Bit Rate |
50 kbit/s to 1 Mbit/s |
CAN FD Bit Rate |
Up to 8 Mbit/s (with correct physical layer implementation) |
Time stamp resolution |
2 μs |
Max message rate |
20000 msg/s per channel |
Error Frame Detection |
Yes |
Error Frame Generation |
No |
Silent mode |
Yes – Always on |
Kvaser MagiSync |
No |
Kvaser CANtegrity |
No |
Host interface |
USB 2.0 |
Host OS |
Windows (7 or later), Linux, Android. |
External power |
9–40 V |
Power consumption |
Up to 3W |
Hardware configuration |
Done by software (Plug & Play). |
Dimensions |
46 x 127 x 22 mm for body incl. strain relief |
Weight |
150 g |
Operating temperature |
−40 ◦C to +85 ◦C |
Storage temperature |
−40 ◦C to +85 ◦C |
Relative humidity |
0 % to 85 % (non-condensing.) |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review CAN data logger single-channel Kvaser Memorator Light HS v2
There are no reviews yet.