Precision sound calibrator Larson Davis CAL250

Price: Contact

Model CAL250
Manufacturer LARSON DAVIS (a part of the PCB PIEZOTRONICS)
Power supply 6.7 V to 10 V
Weight 156 g
Size 124 x 44.5 mm
Condition Stocking
Warranty 12 months

IEC 60942 Class 1 Precision sound calibrator Larson Davis CAL250 for 1" microphones at 251.2 Hz Used for Sound Level Meters and Other Sound Measuring Equipment

I. Specifications of Portable sound level calibrator Larson Davis CAL250

1" MICROPHONES - IEC 60942 CLASS 1 CALIBRATOR

Precision sound calibrator Larson Davis CAL250 is a battery operated precision microphone calibrator for 1" microphones used for the calibration of sound level meters and other sound measurement equipment.

The CAL250 delivers a full 114.0 dB level output signal at 251.2 Hz. A 1/2" microphone adaptor is supplied with the CAL250. Adaptors for 1⁄8", ¼", and 3⁄8" microphones are available as optional accessories.

It has been designed for both field and laboratory use and the accuracy has been calibrated to a reference traceable to the National Institute of Standards and Technology (NIST).

The Larson Davis CAL250 features a stable sound pressure independent of the battery condition. In addition, the CAL250 will turn off automatically to preserve battery and guarantee a stable output.

In addition to precision acoustic calibrators, factory calibration services for Larson Davis products are available through the CAL+ program. CAL+ service is provided with all Larson Davis calibrations and includes a complete multi-point factory test, free firmware upgrade to the latest version where applicable, labor warranty extended for one year[1], worn consumables replaced at no charge[2], and more. Contact us for details.

HIGHLIGHTS

  • Output level: 114 dB
  • Output frequency: 251.2 Hz
  • Standard: 1" microphone
  • IEC 60942-1:2003 compliant
  • Internal battery
  • Output level independent of battery condition
  • Adaptors: ¹⁄8", 1/4", 3⁄8", 1/2" microphones
  • Array adaptor for 8 microphones simultaneously.

TYPICAL APPLICATIONS

Field or laboratory calibration of:

  • Sound level meters
  • Noise dosimeters
  • Noise monitoring stations
  • Microphone arrays.

Technical specifications of Precision sound calibrator Larson Davis CAL250

SPECIFICATIONS

Acoustic

Calibration Sound PressureLevel Initial

After 1 Year

114.0 dB ± 0.1 dB re: 20 μPa

± 0.2 dB re: 20 μPa

Equivalent Free-field Level

0.0 dB for 1/2″ microphones

Frequency

251.2Hz ± 0.7%

Harmonic Distortion

< 2 %

Stability After Pressing On

± 0.1 dB after 2 seconds

Minimum Stabilizing Time

10 seconds after coupling microphone and calibrator

Reference Conditions

101.3 kPa, 23 ºC and 50 % RH

Environmental

Static Pressure Range

65 kPa to 108 kPa

SPL variation < ± 0.25 dB

Temperature Range

-10 ºC to +50 ºC

SPL variation < ± 0.4 dB
Frequency variation < ± 2 Hz

Humidity Range

10 % to 90 % RH non-condensing

SPL variation < ± 0.4 dB
Frequency variation < ± 2 Hz

Storage Temperature

-40 ºC to +60 ºC

Storage Humidity

0 % to 90 % RH (non-condensing)

Physical

Effective Volume of Calibrator and Microphone

> 6.1 in3 (100 cm3)

Dimensions (L x W x H)

4.9 x 1.75 in (124 x 44.5 mm)

Weight

5.5 oz (156 g)

Power Supply

Battery

9 V NEDA 1604 A or IEC 6LR61

Battery Voltage Operating Range

6.7 V to 10 V

Traceability

Traceability

Traceable to National Institute of Standards and Technology (NIST)

Supplied Accessories

ADP019 Adaptor for 1/2″ Microphone

CCS003 Storage Case

9 V Alkaline Battery

Users Manual

Related Products

ADP020

Adaptor for 3⁄8″ microphones

ADP021

Adaptor for 1/4″ microphones

ADP023

Adaptor for 1⁄8″ microphones

ADP031

Adaptor for 3⁄8″ microphones

COMPLIANCE

Acoustic

ANSI S1.40-2006, Class 1

IEC 60942-2003, Class 1

IEC 60942:2017, Class 1

Safety

IEC 61010-1:2001

EMC

EU directive 2004/108/EC

IEC 61326-1:2005

For Use with Microphones of Type

IEC 61094-4:1995

1″ WS1P, WS1F and WS1D

1/2″ WS2P, WS2F and WS2D microphones; with ADP019 adaptor

1/4″ WS3P, WS3F and WS3D microphones with ADP021 adaptor

According to IEC 61094-1:2000

1/2″ LS2P

Other Microphones

3⁄8″ with ADP020 adaptor

1⁄8″ with ADP023 adaptor

For Use with Sound Level Meters and Noise Dosimeters

ANSI S1.4 Type 1

ANSI S1.25

IEC 61672 Class 1

IEC 61252

[1] Requires regular annual factory calibration. Limited to seven (7) years.

[2] Windscreen, O-rings, desiccants, fuses, for example.

Review Precision sound calibrator Larson Davis CAL250

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Precision sound calibrator Larson Davis CAL250
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide

      OTHER SAME PRODUCTS

      Industrial endoscope camera JK series 7 ” 360 °

      Model: JKVS / JKS / JKVS(R) / JKR / JKS(R)