I. Specifications of Acoustic couplers & Ear simulators Larson Davis Series AEC & AMC

FOR AUDIOMETRIC CALIBRATION AND PRODUCTION TESTING

Whether testing an earphone, hearing aid, or audiometer, there is Acoustic couplers and Ear simulators Larson Davis Series AEC & AMC to satisfy your requirements.

  • Supra-aural earphones
  • Circumaural headsets
  • Bone vibrators
  • Insert earphones
  • Hearing aids.

TYPICAL APPLICATIONS

  • Audiometer calibration
  • Production testing
  • Hearing aid test
  • Research & Development.

 

II. Acoustic couplers and Ear simulators Larson Davis Series AEC & AMC

With a range of options, you can test virtually every device including supra-aural and circumaural headsets, bone vibrators, insert earphones, and hearing aids.

SUPRA-AURAL & CIRCUMAURAL EARPHONES

EAR SIMULATOR MODEL AEC201-A

  • Used at frequencies up to 16000 Hz
  • Meets IEC 60318-1:2009 Edition 2 and ANSI S3.7 section 5.4 requirements
  • Compatible with earphones like TDH 39, TDH 49, TDH 50, HDA200 and Koss HV/1A
  • Supplied with 377B13 microphone and Type 1 adapter plate (Type 2 available)
  • Weights, accessories and the AEC201-A are all packaged in a durable weather-tight case.

Acoustic-couplers-and-ear-simulators-larson-davis-series-aec-amc

INSERT EARPHONES

OCCLUDED EAR SIMULATOR MODEL AEC304

  • Designed to test insert earphones
  • Includes ½ inch 12.5 mV/Pa matched microphone
  • Meets IEC 60318-4 and IEC 60711:1981 requirements
  • Often referred to as a Series 711 Coupler.

Acoustic-couplers-and-ear-simulators-larson-davis-series-aec-amc

INSERT HEARING AIDS AND EARPHONES

COUPLER MODELS AEC202 & AEC203

  • Use AEC202 for ½ inch microphones
  • Used for 1 inch microphones
  • Both units meet IEC 60126 and IEC 60318‑5 requirements
  • AEC202 meets ANSI S3.7 2cc and AEC203 meets ANSI S3.7.

Acoustic-couplers-and-ear-simulators-larson-davis-series-aec-amc

SUPRA-AURAL EARPHONES

NBS 9 A 6CC COUPLER MODEL AEC100

  • Designed for 1–inch microphones (not included) and the calibration testing of supra-aural earphones
  • Delivers accurate and repeatable measurements up to 8 kHz
  • Used for production testing where correlation between the coupler and real ear response is not a requisite.

Acoustic-couplers-and-ear-simulators-larson-davis-series-aec-amc

BONE VIBRATOR TESTS

ARTIFICIAL MASTOID MODEL AMC439C

  • The AMC493C artificial mastoid is a precision mechanical coupler used to calibrate bone conduction hearing aids and audiometer bone vibrators. The AMC493C is cost effective and simple to use. Its patented design converts the vibrator force output to an acoustic signal measured with the system’s sound level meter. It is used with the AEC100 coupler or AEC201-A Ear Simulator to perform bone vibrator tests.

Acoustic-couplers-and-ear-simulators-larson-davis-series-aec-amc

WHICH COUPLER SHOULD I USE FOR CALIBRATING AUDIOMETERS?

Head phone

AEC100

AEC201-A

AEC202

AEC203

AEC304

RETSPL

Notes

Ear Tone
ER-3A/5A

 

 




(Occluded)

ISO 389-2
ANSI S3.6

 

Koss HV/1A

 


 

 

 

ISO 389-5
ANSI S3.6

Use 9-10 N weight and optional AEC201-2

Telephonics TDH-39 3



 

 

 

ISO 389-1
ANSI S3.6

Use 4-5 N weight

Telephonics TDH-49


 

 

 

ISO 389-1
ANSI S3.6

Use 4-5 N weight

Telephonics TDH-50


 

 

 

ISO 389-1
ANSI S3.6

Use 4-5 N weight

Sennheiser HDA200

 



 

 

 

ISO 389-5
ISO 389-8
ANSI S3.6

Use 9-10 N weight and
type 1 adapter plate

Sennheiser HDA280


 

 

 

ISO 389-1
ANSI S3.6
Sennheiser

Use 4-5 N weight

Sennheiser HDA300

 

 

 

Sennheiser

Use 4-5 N weight

Beyer DT-48


 

 

 

ISO 389-1
ANSI S3.6

Use 4-5 N weight

Interacoustics DD45

 

 

 

Interacoustics

Use 4-5 N weight

Radio Ear B-71


 

 

 

ISO 389-3
ANSI S3.6

Use 4-5 N weight and optional AMC493C
weighting mass

Technical specifications of Acoustic couplers and Ear simulators Larson Davis Series AEC & AMC

Coupler 

AEC100 

AEC201-A 

AEC202 

AEC203 

AEC304 

Description 

NBS 9A (6 cc) Coupler 

Ear Simulator 

1/2 in 2cc Coupler 

1 in 2cc Coupler 

IEC711 Ear Simulator 

Standards Compliance

IEC 60318-3:1998
ANSI S3.7-1995

IEC 60318-1:2009
IEC 60318-2:1998
ANSI S3.7-1995, Sec 5.4

IEC 60318-5:2006
ANSI S3.7-1995

IEC 60318-5:2006
ANSI S3.7-1995

IEC 60318-4:2010

CE Compliant 

– 

Yes 

Yes 

Yes 

Yes 

ANSI S3.6 Test Configuration 

– 

– 

HA-1, HA-2 

HA-2 

– 

Weight 

5.5 lb (2.5 kg) 

3.2 lb (1.4 kg) 

2.7 oz (77.5 g) 

1.7 oz (49.0 g) 

3.3 oz (94.8 g) 

Height 

2.5 in (65 mm) without mass and retainer 

2.0 in (50.9 mm) without mass and retainer 

1.62 in (4.12 cm) 

1.55 in (3.94 cm) 

1.5 in (3.81 cm) 

Diameter 

3.2 in (82 mm) 

3.2 in (82 mm) 

0.98 in (2.48 cm) 

0.98 in (2.48 cm) 

0.94 in (2.37 cm) 

Effective Volume 

6 cc 

– 

2 cc 

2 cc 

– 

Microphone 

1 in 377A15 or LD 2575 (not included) 

1/2 in 377B13 (included) 

1/2 in 377B13 or 1/2 in 377B11 (not included) 

1 in 377A15 or LD 2575 (not included) 

1/2 in 377B13 (included) 

Included Accessories 

Vibration isolation pillow 

Vibration isolation pillow 

0.035 in hex key, acoustic tubing #13 thick 

acoustic tubing #13 thick 

– 

Optional Accessories 

377A15 microphone
2575 microphone
CAL250 Calibrator
AMC493C
Artificial Mastoid

AEC201-2 Type 2 adapter plate for circumaural earphones AMC493C Artificial Mastoid

377B13 or 377B11 microphone 

377A15 microphone
2575 microphone
CAL250 Calibrator

CAL250 Calibrator 

Additional Features 

– 

377B13 is removable 

Earmold substitute for BTE hearing aids, cup for insert headphones and ITE hearing aids 

Can be used with AEC100 to share 1 inch microphone 

Can be calibrated using CAL250 by removing top cone and mesh 

Applications 

– 

– 

IIC, CIC, ITC, ITE, RIC, BTE 

BTE 

ITC, ITE, RIC 

 

Bảng đặc điểm kỹ thuật Từ viết tắt

HA-1

Without Ear Mold Substitute

HA-2

With Ear Mold Substitute

IIC

Invisible In Canal

CIC

Completely In Canal

ITC

In The Canal

ITE

In The Ear

RIC

Receiver In Canal

BTE

Behind The Ear

Review Acoustic couplers and Ear simulators Larson Davis Series AEC & AMC

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Acoustic couplers and Ear simulators Larson Davis Series AEC & AMC
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide