Product

Categories

Process Equipment

Showing 1–6 of 63 results

Reverberation time sound level meter Larson Davis 831C-RT

Model: 831C-RT

Whether for performance venues, architectural measurements, or work-place acoustics, reverberation time is a key parameter for characterizing a room. Reverberation time data provides information about the quality of sound as perceived by the audience in a room. A long reverberation time can make speech less intelligible, and music more pleasing. Too short a reverberation time can muffle speech and make a room sound “thin.”  Reverberation time sound level meter Larson Davis 831C-RT with Room Acoustics Firmware 831C-RA offers reverberation time measurement and calculation.

  • Calculates reverberation time (RT60)
  • Ensures measurement reliability with ensemble averaging
  • Serves as pink and white noise source
  • Supports optional amplifiers and omni-directional or façade speakers
  • Triggers measurement automatically
  • 1/1 and 1/3 octave filters supported
  • Offers measurement quality indicators and grading.

Impulsive sound source Larson Davis BAS006

Model: BAS006

Impulsive sound source Larson Davis BAS006 is an innovative device used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce.

  • Use for ISO 10140, ISO 140, DIN 52210,and BS 5821 Measurements
  • Maintenance Free Design
  • Simple, Easy-to-Use.

DC bias current source MICROTEST 6210 (10A)

Model: 6210

DC bias current source MICROTEST 6210 (10A) is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors.

  • Max current output: 60A (6 unit)
  • Each individual unit can output DC bias current: 10A
  • Option 6632 Impedance analyzer.

DC bias current source MICROTEST 6220 (20A)

Model: 6220

DC bias current source MICROTEST 6220 (20A) is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors.

  • Max current output: 120A (6 unit)
  • Each individual unit can output DC bias current: 20A
  • Option 6632 Impedance analyzer.

DC bias current source MICROTEST 6240 (40A)

Model: 6240

DC bias current source MICROTEST 6240 (40A) is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors.

  • Max current output: 320A (8 unit)
  • Each individual unit can output DC Bias Current 40A
  • Option LCR meter/Impedance analyzer.

DC bias current source MICROTEST 6225 (20A)

Model: 6225

DC bias current source MICROTEST 6225 (20A) is designed for performing magnetic saturation current (Isat) and temperature rise current analysis (Irms) on inductors.

  • Max current output: 20A
  • Each individual unit can output DC bias current 20A
  • Option 6632 impedance analyzer.