Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
Price: Contact
Model | 730IS |
Manufacturer | LARSON DAVIS (a part of the PCB PIEZOTRONICS) |
Power supply | Rechargeable NiMH |
Weight | 130 g |
Size | 85 x 54 x 39 mm |
Condition | Stocking |
Warranty | 12 months |
Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS is simple design and intuitive setup make getting worker noise dose measurements easy and fast.
I. Specifications of Spartan™ intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
WORKERS NOISE EXPOSURE MEASUREMENTS IN EXPLOSIVE ENVIRONMENTS
- Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS is designed to safely make noise exposure measurements, even for workers in explosive environments, such as those found in the petrochemical industry and pharmaceutical manufacturing.
- With Spartan-IS, control test setup and measurements either on the device itself or directly from the Larson Davis Atlas™ mobile app. All essential tasks can be completed from your iOS or Android device.
TYPICAL APPLICATIONS
- Worker noise exposure measurements
- Risk mitigation studies
- Measuring for compliance to OSHA, ACGIH, ISO 9612, EU Directive 2003/10/EC, and MSHA 30 CFR 62.100
- Underground mine noise exposure studies.
WIRELESS WORKER NOISE MEASUREMENTS
- ATEX, MSHA, UL 913, IECEx, ANZEx, FCC, UKCA, CAN/CSA C22.2 approved
- Wireless operation, charging, and Bluetooth low-energy communication (available without Bluetooth for radio-free zones)
- Full control and live monitoring via LD Atlas™ app*
- Download and view measurements, generate reports, and share annotated data from your mobile device
- Built-in bump and motion detection
- Automatic dosimeter calibration.
To begin testing, simply remove the dosimeters from their rugged case and attach them to workers. After a shift, place the dosimeters back in the case where they will charge wirelessly. The G4 LD Utility software offers another option for control of your testing. With all the functionality of the LD Atlas mobile app, G4 LD Utility adds the ability to complete "what-if" analysis to model potential changes and determine the impact of different data selections.
LD Atlas offers interference-free monitoring using low-energy Bluetooth, ensuring that you get the valuable data you need the first time. When a test is complete, Spartan-IS communicates with LD Atlas to download the data, which is viewable directly from a phone or tablet. Generate reports, including the full data file, from the mobile interface before sharing via email. For high security, radio-free zones, option 730-NBT without Bluetooth is available and allows setup and data download through G4 LD Utility software via a USB connection.
INTRINSIC SAFETY RATINGS/MARKING
ATEX / IECEx / UKCA / ANZEx |
USA / CAN |
MSHA |
II 1G Ex ia IIC T165 °C Ga |
Class I, Zone 0, AEx ia IIC |
Model 730IS |
II. LD Atlas™ Mobile App for Wireless noise dosimeter Larson Davis Spartan™ 730
NOISE & VIBRATION MONITORING - CONNECT, MEASURE, ANALYZE
LD Atlas™ is a free mobile app for use with your new Larson Davis equipment. Install LD Atlas on your phone or tablet - available for both iOS and Android - and connect to your Spartan™ Series Noise Dosimeters, SoundAdvisor™ Sound Level Meter Model 831C, and Human Vibration Meter Model HVM200. Connect to your meter and use LD Atlas to easily check on the status of your meter, make setup changes for a new measurement, analyze data, listen to recorded audio files, and even create and share PDF reports with your own company logo on them.
Connections are made to the Spartan Series meters seamlessly over Bluetooth Low-Energy, without the need to pair devices, or via the IP address of your Sound Advisor 831C or HVM200. Data is presented within a spreadsheet view, time history graphs, and octave band analysis breakdown.
LD Atlas™ MOBILE APP OFFERS
- Management of meters connected to the internet
- Calibration of meters
- Ability to review data and preview graphs
- Report production and sharing
- Annotation of data with speech-to-text
- Playback of sound recording files
- Download of files via Bluetooth connection.
III. Ordering Information Noise Dosimeter, Kits, Options, and Accessories | Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
MODEL NUMBER |
DESCRIPTION |
||||
730IS |
Spartan 730IS noise dosimeter with one windscreen and two clips. Includes calibration certificate |
||||
730IS-PKxx-EU 730IS-PKxx-UK 730IS-PKxx-US |
Complete Spartan 730IS noise dosimeter kit that includes quantity `xx' dosimeters. Each dosimeter includes one windscreen, two clips, and a calibration certificate. Versions without CAL150 calibrator available. |
||||
`xx' |
Spartan 730IS Dosimeters |
Calibrator (qty 1) |
Calibration Adapter |
Case |
|
01 |
1 |
CAL150 |
1 x ADP109 |
CCS056 |
|
03 |
3 |
CAL150 |
1 x ADP109 |
CCS057 |
|
05 |
5 |
CAL150 |
1 x ADP109 |
CCS058 |
|
10 |
10 |
CAL150 |
1 x ADP109 |
CCS059 |
|
* EU includes a Type C power plug for use in Europe |
|||||
730-ESR |
Spartan 730IS option to add event sound recording |
||||
730-OB1 |
Spartan 730IS option to add 1/1 octave filters |
||||
730-NBT |
Spartan 730IS option to remove Bluetooth capability |
||||
ACCESSORIES |
|||||
CAL150 |
Class 2 calibrator, with user-selectable output 94 or 114 dB at 1 kHz, ½ in. opening with ¼ in. adaptor (ADP109) and calibration certificate included. |
||||
WS012-XX |
Replacement windscreen for Spartan 730IS. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens. |
||||
730-CLIPS |
Replacement clip for Spartan 730IS, quantity 2 |
||||
ADP106 |
BNC to ¼ inch microphone electrical equivalent with 8 pF capacitance used for electrical testing of the Spartan 730IS |
||||
ADP109 |
Calibrator adaptor for ½ in. to ¼ in. opening. Used with Spartan 730IS |
||||
BAT022 |
Replacement lithium battery for Spartan 730IS. Must be installed at a factory-authorized location. Does not include fee for installation. |
||||
CCS056 |
Spartan 730IS case for single dosimeter kit that includes single wireless charger and universal power adapter. Spartan 730 and CAL150 not included |
||||
CCS057-EU |
Spartan 730 case for three dosimeter kit that include three wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730 dosimeters and CAL150 not included |
||||
CCS058-EU |
Spartan 730IS case for five dosimeter kit that include five wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730ISdosimeters and CAL150 not included |
||||
CCS059-EU |
Spartan 730IS case for ten dosimeter kit that include ten wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730IS dosimeters and CAL150 not included |
||||
CER-730 |
ISO 17025 factory calibration and certification of Spartan 730IS |
||||
CER-730-OBA |
Calibration and certification for Spartan 730 dosimeter including 1/1 octave filters. ISO 17025 accredited |
||||
DVX017 |
USB to Bluetooth dongle for Windows 10 & 11 used with Spartan 730IS |
||||
PSA042 |
Wireless Qi charger pad including USB cable and universal power supply |
||||
WS012-XX |
Replacement windscreen for Spartan 730. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens |
||||
375A03 |
Replacement ¼ inch microphone for Spartan 730IS dosimeter |
||||
CER-CAL150 |
Calibration and certification for CAL150. |
||||
INTRINIC SAFETY RATINGS |
|||||
ATEX/IECEx |
II 1G Ex ia IIC T165 °C Ga |
||||
USA/CANADA |
Class I, Zone 0, AEx ia IIC T165 °C Ga |
Technical specifications of Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
SPECIFICATIONS |
|
Performance |
|
Standards |
ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 |
Linear Operating Range |
52 – 140 dB rms A-weighted |
Dynamic Range |
94 dB |
Peak Range |
78 – 143 dB Peak, C-weighted |
Peak Weightings |
A, C, Z |
RMS Weightings |
A, C, Z |
Time Weightings |
Slow, Fast, Impulse |
Frequency Range |
20 Hz to 10 kHz |
Data Logging |
Selectable 1 second or 1 minute samples |
Logged Data |
LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion |
Memory |
2 GB internal |
Communications |
Bluetooth Low Energy 4.1 |
USB 2.0 (Micro-B connector) |
|
Battery |
Rechargeable NiMH |
Run Time |
30 hours, typical |
Charge Time |
16 hours from full discharge |
Charger |
Qi-compliant wireless or USB |
Compliance |
CE, ROHS, WEEE |
Approvals |
ATEX, UL 913, IECEx, FCC, UKCA, CAN/CSA C22.2 |
Motion |
Overall motion percentage and bump |
Languages |
English, Spanish, Italian, French, Portuguese, German |
Virtual Dosimeter |
|
Virtual Dosimeters |
4 independent with configurable LED indication |
Exchange Rate |
3, 4, 5, 6 |
Criterion Level |
70.0 to 100.0 dB |
Threshold |
70.0 to 100.0 dB |
Shift Time |
1 to 24 hours |
Alarms |
2 independent with configurable indication |
Measurement Results |
Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d |
Summary Measured Values (Common to all virtual dosimeters) |
|
Lωτ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωτMax (Lmax), LωτMin (Lmin) where |
|
Mechanical |
|
Display |
Color LCD 176 x 176 pixels, always on with low light sensor and front light |
Ingress Protection |
IP65 |
Weight |
130 g (4.6 oz.) including clips and windscreen |
Dimensions |
85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only |
Microphone |
¼-inch Model 375A03 |
Operating Temperature |
-10 to +50 °C (14 to 122 °F) |
Operating Humidity |
Up to 90% RH, non-condensing |
1/1 Octave Filters (optional) |
|
Filters |
31.5 Hz to 8 kHz |
Event Audio Recording (optional) |
|
Format |
16-bit .wav |
Sample Rate |
8 kHz |
Recording Time |
Fixed: 2 s pre-trigger and 10 s post-trigger |
Trigger Source |
LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
There are no reviews yet.