Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS

Price: Contact

Model 730IS
Manufacturer LARSON DAVIS (a part of the PCB PIEZOTRONICS)
Power supply Rechargeable NiMH
Weight 130 g
Size 85 x 54 x 39 mm
Condition Stocking
Warranty 12 months

Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS is simple design and intuitive setup make getting worker noise dose measurements easy and fast.

I. Specifications of Spartan™ intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS

WORKERS NOISE EXPOSURE MEASUREMENTS IN EXPLOSIVE ENVIRONMENTS

  • Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS is designed to safely make noise exposure measurements, even for workers in explosive environments, such as those found in the petrochemical industry and pharmaceutical manufacturing.
  • With Spartan-IS, control test setup and measurements either on the device itself or directly from the Larson Davis Atlas™ mobile app. All essential tasks can be completed from your iOS or Android device.

TYPICAL APPLICATIONS

  • Worker noise exposure measurements
  • Risk mitigation studies
  • Measuring for compliance to OSHA, ACGIH, ISO 9612, EU Directive 2003/10/EC, and MSHA 30 CFR 62.100
  • Underground mine noise exposure studies.

WIRELESS WORKER NOISE MEASUREMENTS

  • ATEX, MSHA, UL 913, IECEx, ANZEx, FCC, UKCA, CAN/CSA C22.2 approved
  • Wireless operation, charging, and Bluetooth low-energy communication (available without Bluetooth for radio-free zones)
  • Full control and live monitoring via LD Atlas™ app*
  • Download and view measurements, generate reports, and share annotated data from your mobile device
  • Built-in bump and motion detection
  • Automatic dosimeter calibration.

To begin testing, simply remove the dosimeters from their rugged case and attach them to workers. After a shift, place the dosimeters back in the case where they will charge wirelessly. The G4 LD Utility software offers another option for control of your testing. With all the functionality of the LD Atlas mobile app, G4 LD Utility adds the ability to complete "what-if" analysis to model potential changes and determine the impact of different data selections.

LD Atlas offers interference-free monitoring using low-energy Bluetooth, ensuring that you get the valuable data you need the first time. When a test is complete, Spartan-IS communicates with LD Atlas to download the data, which is viewable directly from a phone or tablet. Generate reports, including the full data file, from the mobile interface before sharing via email. For high security, radio-free zones, option 730-NBT without Bluetooth is available and allows setup and data download through G4 LD Utility software via a USB connection.

INTRINSIC SAFETY RATINGS/MARKING

ATEX / IECEx / UKCA / ANZEx

USA / CAN

MSHA

II 1G Ex ia IIC T165 °C Ga
I 1M Ex ia I Ma
IECEx ETL 19.0045X
ITS20ATEX205538X
ITS21UKEX0463X
ANZEx 23.3001X
-10 °C ≤ TAMB ≤ +50 °C

Class I, Zone 0, AEx ia IIC
T165 °C Ga
Class I, Division 1,
Groups A, B, C & D, T165 °C
-10 °C ≤ TAMB ≤ +50 ºC

Model 730IS  
PERMISSIBLE Noise Dosimeter
APPROVAL NO. 18-A210001-0
TESTED FOR INTRINSIC SAFETY
IN METHANE-AIR MIXTURES ONLY

 

II. LD Atlas™ Mobile App for Wireless noise dosimeter Larson Davis Spartan™ 730

NOISE & VIBRATION MONITORING - CONNECT, MEASURE, ANALYZE

LD Atlas™ is a free mobile app for use with your new Larson Davis equipment. Install LD Atlas on your phone or tablet - available for both iOS and Android - and connect to your Spartan™ Series Noise Dosimeters, SoundAdvisor™ Sound Level Meter Model 831C, and Human Vibration Meter Model HVM200. Connect to your meter and use LD Atlas to easily check on the status of your meter, make setup changes for a new measurement, analyze data, listen to recorded audio files, and even create and share PDF reports with your own company logo on them.

Connections are made to the Spartan Series meters seamlessly over Bluetooth Low-Energy, without the need to pair devices, or via the IP address of your Sound Advisor 831C or HVM200. Data is presented within a spreadsheet view, time history graphs, and octave band analysis breakdown.

LD Atlas™ MOBILE APP OFFERS

  • Management of meters connected to the internet
  • Calibration of meters
  • Ability to review data and preview graphs
  • Report production and sharing
  • Annotation of data with speech-to-text
  • Playback of sound recording files
  • Download of files via Bluetooth connection.

 

III. Ordering Information Noise Dosimeter, Kits, Options, and Accessories | Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS

MODEL NUMBER

DESCRIPTION

730IS

Spartan 730IS noise dosimeter with one windscreen and two clips. Includes calibration certificate 

730IS-PKxx-EU

730IS-PKxx-UK

730IS-PKxx-US

Complete Spartan 730IS noise dosimeter kit that includes quantity `xx' dosimeters. Each dosimeter includes one windscreen, two clips, and a calibration certificate. Versions without CAL150 calibrator available.

`xx' 

Spartan 730IS Dosimeters

Calibrator (qty 1) 

Calibration Adapter 

Case 

01 

CAL150 

1 x ADP109 

CCS056 

03 

CAL150 

1 x ADP109 

CCS057 

05 

CAL150 

1 x ADP109 

CCS058 

10 

10 

CAL150 

1 x ADP109 

CCS059 

* EU includes a Type C power plug for use in Europe 
* UK includes a Type G power plug for use in the UK 
* US includes a Type A power plug for use in North America 

730-ESR

Spartan 730IS option to add event sound recording 

730-OB1 

Spartan 730IS option to add 1/1 octave filters

730-NBT 

Spartan 730IS option to remove Bluetooth capability

ACCESSORIES

CAL150

Class 2 calibrator, with user-selectable output 94 or 114 dB at 1 kHz, ½ in. opening with ¼ in. adaptor (ADP109) and calibration certificate included.

WS012-XX

Replacement windscreen for Spartan 730IS. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens.

730-CLIPS 

Replacement clip for Spartan 730IS, quantity 2 

ADP106 

BNC to ¼ inch microphone electrical equivalent with 8 pF capacitance used for electrical testing of the Spartan 730IS

ADP109 

Calibrator adaptor for ½ in. to ¼ in. opening. Used with Spartan 730IS

BAT022 

Replacement lithium battery for Spartan 730IS. Must be installed at a factory-authorized location. Does not include fee for installation. 

CCS056 

Spartan 730IS case for single dosimeter kit that includes single wireless charger and universal power adapter. Spartan 730 and CAL150 not included 

CCS057-EU
CCS057-UK
CCS057-US 

Spartan 730 case for three dosimeter kit that include three wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730 dosimeters and CAL150 not included 

CCS058-EU
CCS058-UK
CCS058-US 

Spartan 730IS case for five dosimeter kit that include five wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730ISdosimeters and CAL150 not included 

CCS059-EU
CCS059-UK
CCS059-US 

Spartan 730IS case for ten dosimeter kit that include ten wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730IS dosimeters and CAL150 not included 

CER-730 

ISO 17025 factory calibration and certification of Spartan 730IS 

CER-730-OBA 

Calibration and certification for Spartan 730 dosimeter including 1/1 octave filters. ISO 17025 accredited 

DVX017

USB to Bluetooth dongle for Windows 10 & 11 used with Spartan 730IS 

PSA042 

Wireless Qi charger pad including USB cable and universal power supply 

WS012-XX 

Replacement windscreen for Spartan 730. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens 

375A03 

Replacement ¼ inch microphone for Spartan 730IS dosimeter 

CER-CAL150 

Calibration and certification for CAL150.

INTRINIC SAFETY RATINGS

ATEX/IECEx

II 1G Ex ia IIC T165 °C Ga
I 1M Ex ia I Ma
IECEx ETL 19.0045X
ITS20ATEX205538X
-10 ºC ≤ TAMB ≤ +50 ºC

USA/CANADA

Class I, Zone 0, AEx ia IIC T165 °C Ga
Class I, Division 1, Groups A, B, C & D, T165 °C
-10 °C ≤ TAMB ≤ +50 °C.

Technical specifications of Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS

SPECIFICATIONS

Performance 

Standards 

ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 

Linear Operating Range 

52 – 140 dB rms A-weighted 

Dynamic Range 

94 dB 

Peak Range 

78 – 143 dB Peak, C-weighted 

Peak Weightings 

A, C, Z 

RMS Weightings 

A, C, Z 

Time Weightings 

Slow, Fast, Impulse 

Frequency Range 

20 Hz to 10 kHz 

Data Logging 

Selectable 1 second or 1 minute samples 

Logged Data 

LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion 

Memory 

2 GB internal 

Communications 

Bluetooth Low Energy 4.1

USB 2.0 (Micro-B connector) 

Battery 

Rechargeable NiMH 

Run Time 

30 hours, typical 

Charge Time 

16 hours from full discharge 

Charger 

Qi-compliant wireless or USB 

Compliance 

CE, ROHS, WEEE 

Approvals

ATEX, UL 913, IECEx, FCC, UKCA, CAN/CSA C22.2

Motion 

Overall motion percentage and bump 

Languages 

English, Spanish, Italian, French, Portuguese, German 

Virtual Dosimeter 

Virtual Dosimeters 

4 independent with configurable LED indication 

Exchange Rate 

3, 4, 5, 6 

Criterion Level 

70.0 to 100.0 dB 

Threshold 

70.0 to 100.0 dB 

Shift Time 

1 to 24 hours 

Alarms 

2 independent with configurable indication 

Measurement Results 

Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d 

Summary Measured Values (Common to all virtual dosimeters) 

Lωτ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωτMax (Lmax), LωτMin (Lmin) where
    ω = A, C, or Z frequency weighting
     τ = F, S, or I time weighting
Lpeak, Lmax, & Lmin including time of occurrence
LC-A, Exposure (Pa2s & Pa2h), Motion
Exceedance count and time for 2 rms and 3 peak thresholds
Overload count, duration and percentage

Mechanical 

Display 

Color LCD 176 x 176 pixels, always on with low light sensor and front light 

Ingress Protection 

IP65 

Weight 

130 g (4.6 oz.) including clips and windscreen 

Dimensions 

85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only 

Microphone 

¼-inch Model 375A03 

Operating Temperature 

-10 to +50 °C (14 to 122 °F) 

Operating Humidity 

Up to 90% RH, non-condensing 

1/1 Octave Filters (optional) 

Filters 

31.5 Hz to 8 kHz 

Event Audio Recording (optional) 

Format 

16-bit .wav 

Sample Rate 

8 kHz 

Recording Time 

Fixed: 2 s pre-trigger and 10 s post-trigger 

Trigger Source 

LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s

Review Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS

5 0% | 0 review
4 0% | 0 review
3 0% | 0 review
2 0% | 0 review
1 0% | 0 review
Review Intrinsically safe noise dosimeter Larson Davis Spartan™ 730IS
Choose a image
0 character ( Minimum of 10)
    +

    There are no reviews yet.

    No comments yet

    SIGN UP FOR A CONSULTATION

    Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.

      COMMIT

      100% new product

      COMMIT

      100% refund if the product is of bad quality and not as promised

      24/7 SUPPORT

      Hotline: 0845 969 336

      DELIVERY

      Nationwide

      OTHER SAME PRODUCTS