I. Specifications of Wireless sound dosimeter Larson Davis Spartan™ 730
Wireless noise dosimeter Larson Davis Spartan™ 730 is designed to make worker noise dose measurements easy and fast. With Spartan, control test setup and measurements directly from the Larson Davis Atlas™ mobile app. All essential tasks can be completed from your iOS™ or Android™ device.
LD Atlas offers interference-free monitoring using low-energy Bluetooth, ensuring that you get the valuable data you need the first time. When a test is complete, Spartan communicates with LD Atlas to download the data, which is viewable directly from a phone or tablet. Generate reports, including the full data file, from the mobile interface before sharing via email.
The Spartan Series also includes an Intrinsically Safe Noise Dosimeter Model 730IS, for explosive environments.
TYPICAL APPLICATIONS
- Worker noise exposure measurements
- Task-based noise measurements
- Compliance to OSHA, MSHA, ACGIH, and ISO 9612
- EU Directive 2003/10/EC compliance.
WIRELESS WORKER NOISE MEASUREMENTS
|
To begin testing, simply remove Wireless noise dosimeter Larson Davis Spartan™ from their rugged case and attach them to workers. After a shift, place the dosimeters back in the case where they will charge wirelessly and the data files can be downloaded. Built-in measurement of motion and bumps, combined with optional event audio recordings and 1/1 octave frequency analysis, provide additional data to help you understand what caused the noise.
The G4 LD Utility software offers another option for control of your testing. With all the functionality of the LD Atlas mobile app, G4 LD Utility adds the ability to complete “what-if” analysis to model potential changes and determine the impact of different data selections.
INTRINSICALLY SAFE WIRELESS NOISE DOSIMETERS AVAILABLE
Need to make worker noise exposure measurements in potentially explosive environments, such as those found in the petrochemical industry or pharmaceutical manufacturing? Spartan™ Intrinsically Safe Noise Dosimeter Model 730IS brings the features of Spartan to you in an intrinsically safe design with ATEX, MSHA, UL 913, IECEx, FCC, CAN/CSA C22.2 approvals.
Larson Davis Spartan™ WIRELESS NOISE DOSIMETER KITS
Spartan Kits offer you options from a single noise dosimeter to a set of ten. Each kit comes in a rugged case, ideal for carrying meters into the field. Once your work is complete, simply pack away your dosimeters and move to the next test site. Kits come in one-, three-, five-, and ten-meter configurations and are available with or without calibrators.
730-PK01 |
730-PK03 |
730-PK05 |
730-PK10 |
II. LD Atlas™ Mobile App for Wireless noise dosimeter Larson Davis Spartan™ 730
NOISE & VIBRATION MONITORING - CONNECT, MEASURE, ANALYZE
LD Atlas™ is a free mobile app for use with your new Larson Davis equipment. Install LD Atlas on your phone or tablet - available for both iOS and Android - and connect to your Spartan™ Series Noise Dosimeters, SoundAdvisor™ Sound Level Meter Model 831C, and Human Vibration Meter Model HVM200. Connect to your meter and use LD Atlas to easily check on the status of your meter, make setup changes for a new measurement, analyze data, listen to recorded audio files, and even create and share PDF reports with your own company logo on them.
Connections are made to the Spartan Series meters seamlessly over Bluetooth Low-Energy, without the need to pair devices, or via the IP address of your Sound Advisor 831C or HVM200. Data is presented within a spreadsheet view, time history graphs, and octave band analysis breakdown.
LD Atlas™ MOBILE APP OFFERS
|
III. Ordering Information Noise Dosimeter, Kits, Options, and Accessories | Wireless noise dosimeter Larson Davis Spartan™ 730
MODEL NUMBER |
DESCRIPTION |
||||
730 |
Spartan 730 noise dosimeter with one windscreen and two clips. Includes calibration certificate |
||||
730-PKxx-EU |
Complete Spartan 730 noise dosimeter kit that includes quantity `xx' dosimeters. Each dosimeter includes one windscreen, two clips, and a calibration certificate. Versions without CAL150 calibrator available. |
||||
`xx' |
Spartan 730 Dosimeters |
Calibrator (qty 1) |
Calibration Adapter |
Case |
|
01 |
1 |
CAL150 |
1 x ADP109 |
CCS056 |
|
03 |
3 |
CAL150 |
1 x ADP109 |
CCS057 |
|
05 |
5 |
CAL150 |
1 x ADP109 |
CCS058 |
|
10 |
10 |
CAL150 |
1 x ADP109 |
CCS059 |
|
* EU includes a Type C power plug for use in Europe |
|||||
730-PK01-OPT1 |
Spartan 730 noise dosimeter kit with one dosimeter, one windscreen, two clips, USB Bluetooth dongle, and rugged case with built-in wireless Qi charger. Includes calibration certificate and universal power adapter |
||||
730-ESR |
Spartan 730 option to add event sound recording |
||||
730-OB1 |
Spartan 730 option to add 1/1 octave filters |
||||
730-NBT |
Spartan 730 option to remove Bluetooth capability |
||||
ACCESSORIES |
|||||
730-CLIPS |
Replacement clip for Spartan 730, quantity 2 |
||||
ADP106 |
BNC to ¼ inch microphone electrical equivalent with 8 pF capacitance used for electrical testing of the Spartan 730 |
||||
ADP109 |
Calibrator adaptor for ½ in. to ¼ in. opening. Used with Spartan 730 |
||||
BAT022 |
Replacement lithium battery for Spartan 730. Must be installed at a factory-authorized location. Does not include fee for installation. |
||||
CCS056 |
Spartan 730 case for single dosimeter kit that includes single wireless charger and universal power adapter. Spartan 730 and CAL150 not included |
||||
CCS057-EU |
Spartan 730 case for three dosimeter kit that include three wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730 dosimeters and CAL150 not included |
||||
CCS058-EU |
Spartan 730 case for five dosimeter kit that include five wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730 dosimeters and CAL150 not included |
||||
CCS059-EU |
Spartan 730 case for ten dosimeter kit that include ten wireless chargers. Specify AC plug as "-EU", "-UK", or "-US". Spartan 730 dosimeters and CAL150 not included |
||||
CER-730 |
ISO 17025 factory calibration and certification of Spartan 730 |
||||
CER-730-OBA |
Calibration and certification for Spartan 730 dosimeter including 1/1 octave filters. ISO 17025 accredited |
||||
DVX017 |
USB to Bluetooth dongle for Windows 10 & 11 used with Spartan 730 |
||||
PSA042 |
Wireless Qi charger pad including USB cable and universal power supply |
||||
WS012-XX |
Replacement windscreen for Spartan 730. Available in 1, 3, 5, 10, or 25 packs where XX is the number of windscreens |
||||
375A03 |
Replacement ¼ inch microphone for Spartan 730 dosimeter |
||||
CAL150 |
Class 2 calibrator, with user-selectable output 94 or 114 dB at 1 kHz, ½ in. opening with ¼ in. adaptor (ADP109) and calibration certificate included |
||||
CER-CAL150 |
Calibration and certification for CAL150. |
Technical specifications of Wireless noise dosimeter Larson Davis Spartan™ 730
SPECIFICATIONS |
|
Performance |
|
Standards |
ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 |
Linear Operating Range |
52 – 140 dB rms A-weighted |
Dynamic Range |
94 dB |
Peak Range |
78 – 143 dB Peak, C-weighted |
Peak Weightings |
A, C, Z |
RMS Weightings |
A, C, Z |
Time Weightings |
Slow, Fast, Impulse |
Frequency Range |
20 Hz to 10 kHz |
Data Logging |
Selectable 1 second or 1 minute samples |
Logged Data |
LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, TWA3, TWA5, Motion |
Memory |
32 GB internal |
Communications |
Bluetooth Low Energy 4.1 |
USB 2.0 (Micro-B connector) |
|
Battery |
Rechargeable Lithium Ion |
Run Time |
40 hours, typical |
Charge Time |
3 hours from full discharge |
Charger |
Qi-compliant wireless or USB |
Compliance |
CE, ROHS, WEEE |
Motion |
Overall motion percentage and bump |
Languages |
English, Spanish, Italian, French, Portuguese, German |
Virtual Dosimeter |
|
Virtual Dosimeters |
4 independent with configurable LED indication |
Exchange Rate |
3, 4, 5, 6 |
Criterion Level |
70.0 to 100.0 dB |
Threshold |
70.0 to 100.0 dB |
Shift Time |
1 to 24 hours |
Alarms |
2 independent with configurable indication |
Measurement Results |
Dose; ProjDose; LAVG; TWA(8); Proj TWA(8); Lex,8h; Lep,d; Proj Lep,d |
Summary Measured Values (Common to all virtual dosimeters) |
|
Lωτ (SPL), Lωeq (Leq), Lωpk (Lpeak), LωτMax (Lmax), LωτMin (Lmin) where |
|
Mechanical |
|
Display |
Color LCD 176 x 176 pixels, always on with low light sensor and front light |
Ingress Protection |
IP65 |
Keys |
Four buttons |
Weight |
112 g (4.2 oz.) including clips and windscreen |
Dimensions |
85 x 54 x 39 mm (3.35 x 2.13 x 1.54 in.) dosimeter only |
Microphone |
¼-inch Model 375A03 |
Operating Temperature |
-10 to +50 °C (14 to 122 °F) |
Operating Humidity |
Up to 90% RH, non-condensing |
1/1 Octave Filters (optional) |
|
Standards |
ANSI/ASA S1.11-2014; IEC 61260-1:2014 Class 1 |
Filters |
31.5 Hz to 8 kHz |
Linear Operating Range |
42 to 140 dB @ 1 kHz |
Measured Results |
LZeq (Leq), LZτMax (Lmax), LZτMin (Lmin) |
Event Audio Recording (optional) |
|
Format |
16-bit .wav |
Sample Rate |
8 kHz |
Recording Time |
Fixed: 2 s pre-trigger and 10 s post-trigger |
Trigger Source |
LAS, LAF, LCS, LCF, LAeq,1s, LCeq,1s |
Trigger Level |
40 – 140 dB, selectable |
No comments yet
SIGN UP FOR A CONSULTATION
Please fill in the form below and send your comments and questions to GMGA, we will respond to your email as soon as possible.
COMMIT
100% new product
COMMIT
100% refund if the product is of bad quality and not as promised
24/7 SUPPORT
Hotline: 0845 969 336
DELIVERY
Nationwide
Review Wireless noise dosimeter Larson Davis Spartan™ 730
There are no reviews yet.